首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
化学   3篇
  2019年   1篇
  2016年   1篇
  2011年   1篇
排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
The use of quantitative nuclear magnetic resonance spectrometry for the determination of non‐UV active memantine hydrochloride with relative simplicity and precision has been demonstrated in this study. The method was developed on a 500 MHz NMR instrument and was applied to determination of the drug in a tablet formulation. The analysis was performed by taking caffeine as an internal standard and D2O as the NMR solvent. The signal of methyl protons of memantine hydrochloride appeared at 0.75 ppm (singlet) relative to the signal of caffeine (internal standard) at 3.13 ppm (singlet). The method was found to be linear (r2 = 0.9989) in the drug concentration range of 0.025 to 0.80 mg/ml. The maximum relative standard deviation for accuracy and precision was <2. The limits of detection and quantification were 0.04 and 0.11 mg/ml, respectively. The robustness of the method was revealed by changing nine different parameters. The deviation for each parameter was also within the acceptable limits. The study highlighted possibility of direct determination of memantine hydrochloride in pure form and in its marketed tablet formulation by the use of quantitative NMR, without the need of derivatization, as is the requirement in HPLC studies. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   
2.
Black pepper, though commonly employed as a spice, has many medicinal properties. It consists of volatile oils, alkaloids, pungent resins, etc., of which piperine is a major constituent. Though safe at low doses, piperine causes alteration in the activity of drug metabolising enzymes and transporters at high dose and is known to precipitate liver toxicity. It has a potential to form reactive metabolite(s) (RM) owing to the presence of structural alerts, such as methylenedioxyphenyl (MDP), α, β‐unsaturated carbonyl group (Michael acceptor), and piperidine. The present study was designed to detect and characterize stable and RM(s) of piperine formed on in vitro incubation with human liver microsomes. The investigation of RMs was done with the aid of trapping agents, viz, glutathione (GSH) and N‐acetylcysteine (NAC). The samples were analysed by ultra‐high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC‐HRMS) using Thermo Scientific Q Exactive Plus Orbitrap. Full scan MS followed by data‐dependent MS2 (Full MS‐ddMS2) mode was used to establish mass spectrometric fragmentation pathways of protonated piperine and its metabolites. In total, four stable metabolites and their isomers (M1a‐c, M2a‐b, M3a‐c, and M4a‐b) were detected. Their formation involved removal of carbon (3, M1a‐c), hydroxylation (2, M2a‐b), hydroxylation with hydrogenation (3, M3a‐c), and dehydrogenation (2, M4a‐b). Out of these metabolites, M1, M2, and M3 are reported earlier in the literature, but their isomers and two M4 variants are novel. In addition, six novel conjugates of RMs, including three GSH conjugates of m/z 579 and three NAC conjugates of m/z 435, were also observed.  相似文献   
3.
The aim of this study is to develop a selective adenosine aptamer sensor using a rational approach. Unlike traditional RNA aptamers developed from SELEX, duplex DNA containing an abasic site can function as a general scaffold to rationally design aptamers for small aromatic molecules. We discovered that abasic site-containing triplex DNA can also function as an aptamer and provide better affinity than duplex DNA aptamers. A novel adenosine aptamer sensor was designed using such a triplex. The aptamer is modified with furano-dU in the binding site to sense the binding. The sensor bound adenosine has a dissociation constant of 400 nM, more than tenfold stronger than the adenosine aptamer developed from SELEX. The binding quenched furano-dU fluorescence by 40%. It was also demonstrated in this study that this sensor is selective for adenosine over uridine, cytidine, guanosine, ATP, and AMP. The detection limit of this sensor is about 50 nM. The sensor can be used to quantify adenosine concentrations between 50 nM and 2 μM.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号