全文获取类型
收费全文 | 434篇 |
免费 | 37篇 |
国内免费 | 9篇 |
专业分类
化学 | 373篇 |
晶体学 | 4篇 |
力学 | 15篇 |
数学 | 55篇 |
物理学 | 33篇 |
出版年
2023年 | 4篇 |
2022年 | 10篇 |
2021年 | 14篇 |
2020年 | 23篇 |
2019年 | 18篇 |
2018年 | 34篇 |
2017年 | 19篇 |
2016年 | 37篇 |
2015年 | 24篇 |
2014年 | 35篇 |
2013年 | 57篇 |
2012年 | 38篇 |
2011年 | 50篇 |
2010年 | 23篇 |
2009年 | 30篇 |
2008年 | 10篇 |
2007年 | 14篇 |
2006年 | 9篇 |
2005年 | 8篇 |
2004年 | 8篇 |
2003年 | 2篇 |
2002年 | 5篇 |
2000年 | 1篇 |
1999年 | 2篇 |
1998年 | 1篇 |
1994年 | 1篇 |
1993年 | 2篇 |
1991年 | 1篇 |
排序方式: 共有480条查询结果,搜索用时 265 毫秒
1.
Khalil Farhadi Ramin Maleki Rouhollah Hosseinzadeh Yamchi Hashem Sharghi Mojtaba Shamsipur 《Analytical sciences》2004,20(5):805-809
[5,10,15,20-Tetrakis(4-N,N-dimethylaminobenzene)porphyrinato]Mn(III) acetate (MnTDPAc) was applied as an ionophore for an iodide-selective PVC membrane electrode. The influences of the membrane composition, pH of the test solution and foreign ions on the electrode performance were investigated. The sensor exhibited not only excellent selectivity to iodide ion compared to Cl- and lipophilic anions such as ClO4- and salicylate, but also a Nernstian response with a slope of -59.4 +/- 1.2 mV per decade for iodide ions over a wide concentration range from 1.0 x 10(-2) to 7.5 x 10(-6) M at 25 degrees C. The potentiometric response was independent of the pH of the solution in the pH range of 2 - 8. The electrode could be used for at least 2 months without any considerable divergence in the potential. Good selectivity for iodide ion, a very short response time, simple preparation and relatively long-term stability were the silent characteristics of this electrode. It was successfully used as an indicator electrode in the potentiometric titration of iodide ions, and also in the determination of iodide from seawater samples and drug formulations. 相似文献
2.
Amir Abbas Matin Ramin Maleki Mir Ali Farajzadeh Khalil Farhadi Reza Hosseinzadeh Abolghasem Jouyban 《Chromatographia》2007,66(5-6):383-387
A new method for extraction and analysis of acetone in human urine based on headspace solid phase microextraction using a
mixture of activated carbon and zeolite as sorbents in a PVC matrix coated on a silver wire and its application to the determination
of ketone bodies is described. Unlike commercial fibers, which are coated on fused silica, the coating adheres strongly to
the silver wire and is thermally stable up to 250 °C. After optimization of coating composition and microextraction conditions
the fiber was used for the analysis of acetone in human urine. 相似文献
3.
The polysaccharide, kappa‐carrageenan (κC) was chemically modified to achieve a novel superabsorbent hydrogel via graft copolymerization of methacrylamide (MAM) onto the substrate followed by alkaline hydrolysis. Ammonium persulfate (APS) and N,N′‐methylene bisacrylamide (MBA) were used as a free‐radical initiator and a crosslinker, respectively. The saponification reaction was carried out using sodium hydroxide aqueous solution. Either κC‐g‐PMAM or hydrolyzed κC‐g‐PMAM (PMAM: polymethacrylamide) was characterized by FT‐IR spectroscopy. The effect of grafting variables (i.e. concentration of MBA, MAM, and APS) and alkaline hydrolysis conditions (i.e. NaOH concentration, hydrolysis time and temperature) were systematically optimized to achieve a hydrogel with swelling capacity as high as possible. The swelling capacity of these hydrogels was also measured in various salt solutions. Results indicated that the swelling ratios decreased with an increase in the ionic strength of the salt solutions. This behavior can be attributed to charge screening effect for monovalent cations, as well as ionic crosslinking for multivalent cations. Absorbency of superabsorbing hydrogels was examined in buffer solutions with pH range 1–13. Also, the pH reversibility and on–off switching behavior, at pH values 3.0 and 8.0, makes the synthesized hydrogels good candidates for controlled delivery of bioactive agents. Finally, swelling kinetics in distilled water and various salt solutions was preliminary investigated. Results showed that the swelling in water was faster than in saline solutions. Copyright © 2004 John Wiley & Sons, Ltd. 相似文献
4.
Rahman Hosseinzadeh Ali Sharifi Kourosh Tabar-Heydar Farshid Mohsenzadeh 《Monatshefte für Chemie / Chemical Monthly》2002,133(11):1413-1415
Summary. N,N-Dimethylhydrazones of ketones and aldehydes undergo facile cleavage to the corresponding carbonyl compounds upon exposure
to microwaves in water containing a catalytic amount of PdCl2–SnCl2 in high yields.
Corresponding authors. E-mail: rahman@umz.ac.ir
Received December 27, 2001. Accepted (revised) February 6, 2002 相似文献
5.
Hasani M Shamsipur M 《Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy》2005,61(5):815-821
Interactions of diaza-18-crown-6 and diaza-15-crown-5, as electron donors, with 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), as an electron acceptor, have been investigated spectrophotometrically in acetonitrile and chloroform solutions. The results indicated immediate formation of an electron donor-electron acceptor complex DA: [reaction in text] which is followed by two relatively slow consecutive reactions: [reaction in text]. The pseudo-first-order rate constants for the formation of the ionic intermediate and the final product have been evaluated at various temperatures by computer fitting of the absorbance time data to appropriate equations. The formation constants of the resulting DA complexes have also been determined. The influences of both the azacrown's structure and the solvent properties on the formation of DA complexes and the rates of subsequent reactions are discussed. 相似文献
6.
Copper-catalyzed N-arylation of diazoles can be accomplished using air-stable CuI as a copper source and 1,10-phenanthroline in the presence of KF/Al2O3 as a base. This is a simple and efficient method for the coupling of aryl bromide with diazoles. Different functionalized aryl bromides were coupled with diazoles using this system. 相似文献
7.
Masoumeh Hasani Mojtaba Shamsipur 《Journal of inclusion phenomena and macrocyclic chemistry》1993,16(2):123-137
The formation of ammonium complexes with several crown ethers and cryptands in nitrobenzene, acetonitrile and dimethylformamide solutions was investigated by conductometry at 25°C. Stability constants of the resulting 1:1 complexes sere determined from the molar conductance-mole ratio data and found to vary in the order DC18C6>18C6>DB30C10>DB21C7>DB24C8>DB18C6>15C5>B15C5>12C4, in the case of crown complexes, and in the order C222>C221>C211>C22>C21 for the ammonium cryptates. The stabilities of the complexes varied inversely with the Gutmann donicity of the solvents. Influences of the number of members in the macrocycle, nature of the substituents in the polyether ring, cavity size and dimensionality, conformations of the free and complexed ligands and number of N+–H bonds available for hydrogen bonding are discussed. 相似文献
8.
A conductance study concerning the interaction between ammonium ion and several crown ethers in acetonitrile solution has been carried out at different temperatures. The stability constants of the resulting 11 complexes at various temperatures were determined from the molar conductance-mole ratio data and found to vary in the order DC18C6>18C6>DB30C10>DB21C7>DB24C8>DB18C6>15C5>B15C5. The enthalpy and entropy of complexation were determined from the temperature dependence of the formation constants. The influence on the thermodynamic data of different parameters such as cavity size and dimensionality of crown ethers, nature of substituents in the polyether ring, conformations of the free and complexed ligands, solvent-ligand interaction and number of N–H bonds available for hydrogen bonding are discussed. 相似文献
9.
A novel membrane sensor for selective monitoring of iodide, consisting of a triiodide‐ketoconazole ion pair complex dispersed in a PVC matrix, plasticized with a mixture of 2‐nitrophenyl octyl ether and dioctylphtalate with unique selectivity toward iodide ions, is described. The influence of membrane composition, pH of test solution and foreign ions on the electrode performance were investigated. The optimized membrane demonstrates a near‐Nernstian response for iodide ions over a wide linear range from 1.0 × 10?2 to 1.0 × 10?5 M, at 25 ± 1 °C. The electrode could be used over a wide pH range 3–10 and has the advantages of high selectivity, fast response time and good lifetime (over 4 months). It was successfully used as indicator electrode in potentiometric titrations and direct potentiometric assay of iodide ions. 相似文献
10.
The triethylamine-based nanomagnetic ionic liquid, [(Et)3 N-H]FeCl4, was synthesized, and its structural and chemical characteristics were detected. The thermogravimetric analysis indicated its high thermal stability with a decomposition temperature higher than 300 °C. Additionally, [(Et)3 N-H]FeCl4 was used to efficiently catalyze the synthesis of xanthene derivatives under solvent-free conditions at 120 °C. [(Et)3 N-H]FeCl4 was recycled and reused at least five times.
Graphical abstract