首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   0篇
化学   7篇
物理学   5篇
  2019年   1篇
  2013年   1篇
  2012年   1篇
  2011年   3篇
  2008年   1篇
  2007年   1篇
  1999年   2篇
  1992年   1篇
  1981年   1篇
排序方式: 共有12条查询结果,搜索用时 62 毫秒
1.
3-Methyl-2-butenenitrile (1) cyclodimerised on treatment with lithium diisopropylamide in dimethoxyethane at temperatures between ?78°C and 0°C to 3-amino-4-cyano-1,5,5-trimethyl-1,3-cyclohexadiene (2) the structure of which was established by acid hydrolysis to the known 4-cyano-1,5,5-trimethyl-1-cyclohexene-3-one (3).  相似文献   
2.
In this paper, the parametric scattering of a single extraordinary polarized beam of laser in BaTiO3 photorefractive crystal has been investigated experimentally and theoretically. The resulting pattern consists of beam fanning, isotropic ring, and anisotropic one. Among all parts of scattering pattern, isotropic ring has not been studied as much as beam fanning and anisotropic ring, and there still are some differences in reports about it. Therefore, the study has mainly focused on this part. In this experimental configuration, isotropic ring is just visible in positive angles although the other parts of parametric scattering pattern can be visible from behind and in front of the crystal. In addition to steady state pattern in forward and backward directions, its transient behavior with the rotation of crystal has been studied. The results of experiments have been analyzed carefully, and their theoretical explanations have been presented based on the standard theory of parametric scattering in photorefractive crystals. It has been shown that this configuration corresponds to the so called parametric B-process scattering.  相似文献   
3.
Series of wavefunctions for the ground state of BeH2 have been compared in the frameworks of the valence bond and the molecular orbital theories for Be-H distances between 1·5 a.u. and 6·0 a.u. using minimum basis sets of Slater-type orbitals with exponents optimized at each internuclear distance. It is confirmed that the model based on the resonance valence state can be useful, particularly when ionic configurations are incorporated with it, although the model emphasizing perfect pairing and including an additional parameter to determine ionic character provides significantly the lowest energies for cases where there is a single degree of freedom in the mixing of valence bond structures. Both molecular orbital and valence bond calculations indicate it is a very good approximation to consider BeH2 as involving localized electron-pair bonds.  相似文献   
4.
The self-chemical ionization of diethylzinc is examined by Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry and semiempirical molecular orbital calculations. Electron impact of diethylzinc neutral produces the radical cation, C(4)H(15)Zn(+) (m/z x 122), which reacts further with the neutral (C(2)H(5))(2)Zn to give the following product ions: Zn(+) (m/z x 64), C(2)H(5)Zn(+) (m/z x 93), C(4)H(9)Zn(+) (m/z x 121), C(4)H(11)Zn(2)(+) (m/z x 187), and C(6)H(15)Zn(2)(+) (m/z x 215). To determine the structure and pathways for production of these ions, monoisotopic (12)C(4)H(15)(64)Zn(+), (64)Zn(+) and (12)C(2)H(5)(64)Zn(+) were individually isolated and reacted with the neutral background. We also performed semiempirical molecular orbital calculations (ZINDO/1). The molecular orbital calculations and experimental data are consistent in predicting that the ethyl group on the diethylzinc cation carries the positive charge. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
5.
We present a simple method for fabricating chemically-inert Teflon microfluidic valves and pumps in glass microfluidic devices. These structures are modeled after monolithic membrane valves and pumps that utilize a featureless polydimethylsiloxane (PDMS) membrane bonded between two etched glass wafers. The limited chemical compatibility of PDMS has necessitated research into alternative materials for microfluidic devices. Previous work has shown that spin-coated amorphous fluoropolymers and Teflon-fluoropolymer laminates can be fabricated and substituted for PDMS in monolithic membrane valves and pumps for space flight applications. However, the complex process for fabricating these spin-coated Teflon films and laminates may preclude their use in many research and manufacturing contexts. As an alternative, we show that commercially-available fluorinated ethylene-propylene (FEP) Teflon films can be used to fabricate chemically-inert monolithic membrane valves and pumps in glass microfluidic devices. The FEP Teflon valves and pumps presented here are simple to fabricate, function similarly to their PDMS counterparts, maintain their performance over extended use, and are resistant to virtually all chemicals. These structures should facilitate lab-on-a-chip research involving a vast array of chemistries that are incompatible with native PDMS microfluidic devices.  相似文献   
6.
怀孕期头发中一些元素含量的变化趋势   总被引:5,自引:1,他引:4  
用同步辐射激发X射线荧光分析,对11个产妇怀孕期间头发内一些元素含量的变化趋势进行了测量,在各自对比的基础上,得到了一些结果。  相似文献   
7.
Precision frequency detection has enabled the suspended microchannel resonator (SMR) to weigh single living cells, single nanoparticles, and adsorbed protein layers in fluid. To date, the SMR resonance frequency has been determined optically, which requires the use of an external laser and photodiode and cannot be easily arrayed for multiplexed measurements. Here we demonstrate the first electronic detection of SMR resonance frequency by fabricating piezoresistive sensors using ion implantation into single crystal silicon resonators. To validate the piezoresistive SMR, buoyant mass histograms of budding yeast cells and a mixture of 1.6, 2.0, 2.5, and 3.0 μm diameter polystyrene beads are measured. For SMRs designed to weigh micron-sized particles and cells, the mass resolution achieved with piezoresistive detection (~3.4 fg in a 1 kHz bandwidth) is comparable to what can be achieved by the conventional optical-lever detector. Eliminating the need for expensive and delicate optical components will enable new uses for the SMR in both multiplexed and field deployable applications.  相似文献   
8.
We present two methods by which single cells can be mechanically trapped and continuously monitored within the suspended microchannel resonator (SMR) mass sensor. Since the fluid surrounding the trapped cell can be quickly and completely replaced on demand, our methods are well suited for measuring changes in cell size and growth in response to drugs or other chemical stimuli. We validate our methods by measuring the density of single polystyrene beads and Saccharomyces cerevisiae yeast cells with a precision of approximately 10(-3) g cm(-3), and by monitoring the growth of single mouse lymphoblast cells before and after drug treatment.  相似文献   
9.
We present an integrated microelectronic device for amplification and label-free detection of nucleic acids. Amplification by polymerase chain reaction (PCR) is achieved with on-chip metal resistive heaters, temperature sensors, and microfluidic valves. We demonstrate a rapid thermocycling with rates of up to 50 degrees C s(-1) and a PCR product yield equivalent to that of a bench-top system. Amplicons within the PCR product are detected by their intrinsic charge with a silicon field-effect sensor. Similar to existing optical approaches with intercalators such as SYBR Green, our sensing approach can directly detect standard double-stranded PCR product, while in contrast, our sensor does not require labeling reagents. By combining amplification and detection on the same device, we show that the presence or absence of a particular DNA sequence can be determined by converting the analog surface potential output of the field-effect sensor to a simple digital true/false readout.  相似文献   
10.
Shaw J  Payer K  Son S  Grover WH  Manalis SR 《Lab on a chip》2012,12(15):2656-2663
Common techniques used to synchronize eukaryotic cells in the cell cycle often impose metabolic stress on the cells or physically select for size rather than age. To address these deficiencies, a minimally perturbing method known as the "baby machine" was developed previously. In the technique, suspension cells are attached to a membrane, and as the cells divide, the newborn cells are eluted to produce a synchronous population of cells in the G1 phase of the cell cycle. However, the existing "baby machine" is only suitable for cells which can be chemically attached to a surface. Here, we present a microfluidic "baby machine" in which cells are held onto a surface by pressure differences rather than chemical attachment. As a result, our method can in principle be used to synchronize a variety of cell types, including cells which may have weak or unknown surface attachment chemistries. We validate our microfluidic "baby machine" by using it to produce a synchronous population of newborn L1210 mouse lymphocytic leukemia cells in G1 phase.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号