首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
化学   5篇
综合类   1篇
物理学   2篇
  2016年   1篇
  2008年   1篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   1篇
  1999年   1篇
排序方式: 共有8条查询结果,搜索用时 0 毫秒
1
1.
We investigate one of the fundamental reactions in solutions, the neutralization of an acid by a base. We use a photoacid, 8-hydroxy-1,3,6-trisulfonate-pyrene (HPTS; pyranine), which upon photoexcitation reacts with acetate under transfer of a deuteron (solvent: deuterated water). We analyze in detail the resulting bimodal reaction dynamics between the photoacid and the base, the first report on which was recently published. We have ascribed the bimodal proton-transfer dynamics to contributions from preformed hydrogen bonding complexes and from initially uncomplexed acid and base. We report on the observation of an additional (6 ps)(-1) contribution to the reaction rate constant. As before, we analyze the slower part of the reaction within the framework of the diffusion model and the fastest part by a static, sub-150 fs reaction rate. Adding the second static term considerably improves the overall modeling of the experimental results. It also allows to connect experimentally the diffusion controlled bimolecular reaction models as defined by Eigen-Weller and by Collins-Kimball. Our findings are in agreement with a three-stage mechanism for liquid phase intermolecular proton transfer: mutual diffusion of acid and base to form a "loose" encounter complex, followed by reorganization of the solvent shells and by "tightening" of the acid-base encounter complex. These rearrangements last a few picoseconds and enable a prompt proton transfer along the reaction coordinate, which occurs faster than our time resolution of 150 fs. Alternative models for the explanation of the slower "on-contact" reaction time of the loose encounter complex in terms of proton transmission through a von Grotthuss mechanism are also discussed.  相似文献   
2.
Monolithic capillary columns were prepared via ring-opening metathesis polymerization (ROMP) using norborn-2-ene (NBE) and 1, 4, 4a, 5, 8, 8a-hexahydro-1, 4, 5, 8-exo,endo-dimethanonaphthalene (DMN-H6) as monomers. The monolithic polymer was copolymerized with Grubbs-type initiator RuCl(2)(PCy(3))(2)(CHPh) and a suitable porogenic system within the confines of fused silica capillaries of different inner diameter (I.D.). The first part of the study focused on batch-to-batch reproducibility of ROMP-derived capillary monoliths. Capillary monoliths of 200 microm I.D. showed good reproducibility in terms of retention times, with relative standard deviations (RSD) of 1.9% for proteins and 2.2% for peptides. However, the separately synthesized capillary monoliths revealed pronounced variation in back pressure with RSD values of up to 31%. These variations were considerably reduced by cooling of the capillaries during polymerization. Using this optimized preparation procedure capillary monoliths of 100 and 50 microm I.D. were synthesized and the effects of scaling down the column I.D. on the morphology and on the reproducibility of the polymerization process were investigated. In the second part, the applicability of ROMP-derived capillary monoliths to a separation problem common in medical research was assessed. A 200 microm I.D. monolithic column demonstrated excellent separation behavior for insulin and various insulin analogs, showing equivalent separation performance to Vydac C4 and Zorbax C3-based stationary phases. Moreover, the high permeability of monoliths enabled chromatographic separations at higher flow rates, which shortened analysis time to about one third. For the analysis of insulin in human biofluid samples, enhanced sensitivity was achieved by using a 50 microm I.D. ROMP-derived monolith.  相似文献   
3.
We have observed electromagnetically induced transparency in a Doppler broadened molecular cascade system using fluorescence detection. We demonstrate that the power-dependent splitting of lines in the upper-level fluorescence excitation spectrum can be used as a new spectroscopic tool for the measurement of molecular transition dipole moment functions.  相似文献   
4.
采用时齐马尔可夫链方法给出了一种评估教师教学水平的方法,对文[1]所给方法做了适当的改进,拓宽了该方法的应用范围,在多民族院校,使用本法可以克服由于学生基础不同等多方面的原因造成难以比较教师教学水平的难题.  相似文献   
5.
We investigate with femtosecond mid-infrared spectroscopy the vibrational-mode characteristics of the electronic states involved in the excited-state dynamics of pyranine (HPTS) that ultimately lead to efficient proton (deuteron) transfer in H2O (D2O). We also study the methoxy derivative of pyranine (MPTS), which is similar in electronic structure but does not have the photoacidity property. We compare the observed vibrational band patterns of MPTS and HPTS after electronic excitation in the solvents: deuterated dimethylsulfoxide, deuterated methanol and H2O/D2O, from which we conclude that for MPTS and HPTS photoacids the first excited singlet state appears to have charge-transfer (CT) properties in water within our time resolution (150 fs), whereas in aprotic dimethylsulfoxide the photoacid appears to be in a non-polar electronic excited state, and in methanol (less polar and less acidic than water) the behaviour is intermediate between these two extremes. For the fingerprint vibrations we do not observe dynamics on a time scale of a few picoseconds, and with our results obtained on the O-H stretching vibration we argue that the dynamic behaviour observed in previous UV/Vis pump-probe studies is likely to be related to solvation dynamics.  相似文献   
6.
Novel monolithic capillary HPLC columns were prepared via ring opening metathesis polymerization (ROMP) within the confines of fused silica columns with 200 microm i.d. using norborn-2-ene (NBE), 1,4,4a,5,8,8a-hexahydro-1,4,5,8, exo, endo-dimethanonaphthalene (DMN-H6) as monomers, 2-propanol and toluene as porogens and RuCl2(PCy3)2(CHPh) as initiator. Using the monolithic capillary HPLC columns, different sets of analytes (i.e. standard systems) were used for the evaluation of the monolithic columns: (i) a protein standard consisting of six proteins in the range of 5000-66 000 g/mol, (ii) an insulin-albumin standard, and (iii) a peptide standard obtained from a tryptic digest of cytochrome C. With these three different standard systems the reproducibility of synthesis in terms of separation performance proved to be 1-2% relative standard deviation in tR. Variation of polymerization parameters had a significant influence on the monolithic morphology and therefore separation efficiency and back pressure. The maximum analytical loading capacity of ROMP-derived monolithic capillary columns for albumin was found to be 30-125 ng, depending on the monomer content. Long-term stability studies showed no alteration in separation performance.  相似文献   
7.
This paper reports for the first time both, an experimental observation and theoretical calculations of the K2 43Δg state. For the experiment we used cw perturbation-facilitated optical-optical double resonance (PFOODR) spectroscopy. A single mode Ti-sapphire laser and a dye laser served as the pump and probe lasers, respectively. A total of 55 PFOODR signals have been assigned to the 43Δg ← b3Πu transitions. Absolute vibrational numbering was determined by using quantum defect analysis combined with comparing observed intensities with calculated Franck-Condon factors (FCF). For the former we used known parameters from the 23Δg state since the 23Δg and the 43Δg states belong to the same Rydberg series. We report here our experimental and calculated spectroscopic constants, the corresponding RKR potential energy curve, the Franck-Condon table for the 43Δg ↔ b3 Πu system, as well as a comparison with the theoretical potential energy curve. The Te value is found to be 28408.938(52) cm−1.  相似文献   
8.
Investigations into sample preparation procedures usually focus on analyte recovery with no information provided about the fate of other components of the sample (matrix). For many analyses, however, and particularly those using liquid chromatography-mass spectrometry (LC-MS), quantitative measurements are greatly influenced by sample matrix. Using the example of the drug amitriptyline and three of its metabolites in serum, we performed a comprehensive investigation of nine commonly used sample clean-up procedures in terms of their suitability for preparing serum samples. We were monitoring the undesired matrix compounds using a combination of charged aerosol detection (CAD), LC-CAD, and a metabolomics-based LC-MS/MS approach. In this way, we compared analyte recovery of protein precipitation-, liquid-liquid-, solid-phase- and hybrid solid-phase extraction methods. Although all methods provided acceptable recoveries, the highest recovery was obtained by protein precipitation with acetonitrile/formic acid (amitriptyline 113%, nortriptyline 92%, 10-hydroxyamitriptyline 89%, and amitriptyline N-oxide 96%). The quantification of matrix removal by LC-CAD showed that the solid phase extraction method (SPE) provided the lowest remaining matrix load (48–123 μg mL−1), which is a 10–40 fold better matrix clean-up than the precipitation- or hybrid solid phase extraction methods. The metabolomics profiles of eleven compound classes, comprising 70 matrix compounds showed the trends of compound class removal for each sample preparation strategy. The collective data set of analyte recovery, matrix removal and matrix compound profile was used to assess the effectiveness of each sample preparation method. The best performance in matrix clean-up and practical handling of small sample volumes was showed by the SPE techniques, particularly HLB SPE. CAD proved to be an effective tool for revealing the considerable differences between the sample preparation methods. This detector can be used to follow matrix compound elution during chromatographic separations, and the facile monitoring of matrix signal can assist in avoiding unfavourable matrix effects on analyte quantification.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号