首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   6篇
  2022年   2篇
  2012年   1篇
  2007年   2篇
  2006年   1篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
An international project team (including members from US, Canada and UK) has been formed from a number of interested biopharmaceutical companies and regulatory authorities to conduct a cross-organisation collaboration exercise. The results from this exercise demonstrate the robustness of CE-SDS across eight different organisations that used instruments of the same equipment model, the same reagents, and the same methodology. Data generated from the analysis of a series of molecular weight markers showed very good precision with regards to relative migration time (RMT) both within and between organisations. The apparent molecular weight of bovine serum albumin (BSA) was measured with good precision to within approximately 2% RSD across the participants. A representative IgG sample showed similar results with regards to relative migration time of its 3 main components, IgG Light Chain, IgG Non-glycosylated Heavy Chain, and IgG Heavy Chain. Fractional peak area for each peak also showed good agreement, with less than 9% RSD for all peaks. This exercise will facilitate both increased regulatory and industrial opinion of CE for biopharmaceutical analysis.CE in the Biotechnology & Pharmaceutical Industries: 7th Symposium on the Practical Applications for the Analysis of Proteins, Nucleotides and Small Molecules, Montreal, Canada, August 12–16, 2005  相似文献   
2.
An international project team (including members from US, Canada and UK) was formed from a number of interested biopharmaceutical companies and regulatory authorities to conduct a cross-organisation collaboration exercise. The results of the first comparison with eight different organisations that used instruments of the same equipment model, the same reagents, and the same methodology has been reported previously [1]. This report represents the addition of other instruments using a different run buffer. The relative migration times were different, as expected, prohibiting a direct comparison between companies. The within-organisation variability was low for both relative migration time (<0.34% RSD% for all companies save one) and the peak area (<5% RSD% for all companies save one) when measuring the purity of a representative IgG sample. The apparent molecular weight of bovine serum albumin was measured with good precision (less than 10% RSD% across all companies) to the theoretical value when all data is utilized (67.5 kDa compared to 66.4 kDa). For a representative IgG sample, the three main components, IgG Light Chain, IgG Non-glycosylated Heavy Chain, and IgG Heavy Chain, could not be separated, specifically the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain. When the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain were combined for all organisations, the fractional peak area for the IgG Light Chain and IgG Non-glycosylated Heavy Chain + IgG Heavy Chain peak also showed excellent agreement, with less than 7.5 and 3.5% RSD%, respectively. The value of this exercise is in demonstrating the reliability of CE for the determination of apparent size of biopharmaceutical proteins. This underpins the appropriate use of such CE data in support of regulatory submissions.  相似文献   
3.
A mild method for the cleavage of an acetal to afford a rearrangement sensitive diol using B-chlorocatecholborane was developed for the synthesis of the endogenous cannabinoid neurochemical messenger 2-arachidonoylglycerol. The tendency for rearrangement of 2-arachidonoylglycerol to the corresponding 1-arachidonoylglycerol was precluded with this reagent. Features of the partial recyclization to an isomeric acetal provide mechanistic detail.  相似文献   
4.
An international team spanning 19 sites across 18 biopharmaceutical and in vitro diagnostics companies in the United States, Europe, and China, along with one regulatory agency, was formed to compare the precision and robustness of imaged CIEF (ICIEF) for the charge heterogeneity analysis of the National Institute of Standards and Technology (NIST) mAb and a rhPD-L1-Fc fusion protein on the iCE3 and the Maurice instruments. This information has been requested to help companies better understand how these instruments compare and how to transition ICIEF methods from iCE3 to the Maurice instrument. The different laboratories performed ICIEF on the NIST mAb and rhPD-L1-Fc with both the iCE3 and Maurice using analytical methods specifically developed for each of the molecules. After processing the electropherograms, statistical evaluation of the data was performed to determine consistencies within and between laboratory and outlying information. The apparent isoelectric point (pI) data generated, based on two-point calibration, for the main isoform of the NIST mAb showed high precision between laboratories, with RSD values of less than 0.3% on both instruments. The SDs for the NIST mAb and the rhPD-L1-Fc charged variants percent peak area values for both instruments are less than 1.02% across different laboratories. These results validate the appropriate use of both the iCE3 and Maurice for ICIEF in the biopharmaceutical industry in support of process development and regulatory submissions of biotherapeutic molecules. Further, the data comparability between the iCE3 and Maurice illustrates that the Maurice platform is a next-generation replacement for the iCE3 that provides comparable data.  相似文献   
5.
Seth Madren  Linda Yi 《Electrophoresis》2022,43(23-24):2453-2465
Therapeutic monoclonal antibodies (mAbs) are highly heterogeneous as a result of posttranslational modifications (PTMs) during bioprocessing and storage. The modifications that impact mAb product quality are regarded as critical quality attributes and require monitoring. The conventional LC–mass spectrometer (MS) method used for product quality monitoring may require protein A purification prior to analysis. In this paper, we present a high-throughput microchip electrophoresis (<4 min) in-line with MS (MCE–MS) that enables baseline separation and characterization of Fc, Fd′, and light chain (LC) domains of IdeS-treated mAb sample directly from bioreactor. The NISTmAb was used to optimize the MCE separation and to assess its capability of multiple attribute monitoring. The MCE–MS can uniquely separate and characterize deamidated species at domain level compared to LC–MS method. Two case studies were followed to demonstrate the method capability of monitoring product quality of mAb samples from stability studies or directly from bioreactors.  相似文献   
6.

An international project team (including members from US, Canada and UK) was formed from a number of interested biopharmaceutical companies and regulatory authorities to conduct a cross-organisation collaboration exercise. The results of the first comparison with eight different organisations that used instruments of the same equipment model, the same reagents, and the same methodology has been reported previously [1]. This report represents the addition of other instruments using a different run buffer. The relative migration times were different, as expected, prohibiting a direct comparison between companies. The within-organisation variability was low for both relative migration time (<0.34% RSD% for all companies save one) and the peak area (<5% RSD% for all companies save one) when measuring the purity of a representative IgG sample. The apparent molecular weight of bovine serum albumin was measured with good precision (less than 10% RSD% across all companies) to the theoretical value when all data is utilized (67.5 kDa compared to 66.4 kDa). For a representative IgG sample, the three main components, IgG Light Chain, IgG Non-glycosylated Heavy Chain, and IgG Heavy Chain, could not be separated, specifically the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain. When the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain were combined for all organisations, the fractional peak area for the IgG Light Chain and IgG Non-glycosylated Heavy Chain + IgG Heavy Chain peak also showed excellent agreement, with less than 7.5 and 3.5% RSD%, respectively. The value of this exercise is in demonstrating the reliability of CE for the determination of apparent size of biopharmaceutical proteins. This underpins the appropriate use of such CE data in support of regulatory submissions.

  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号