首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   2篇
化学   22篇
数学   1篇
物理学   1篇
  2021年   4篇
  2020年   1篇
  2019年   1篇
  2017年   1篇
  2015年   1篇
  2014年   2篇
  2013年   1篇
  2010年   2篇
  2009年   2篇
  2006年   1篇
  2005年   1篇
  2004年   1篇
  2003年   1篇
  2001年   1篇
  1998年   1篇
  1996年   1篇
  1992年   1篇
  1991年   1篇
排序方式: 共有24条查询结果,搜索用时 15 毫秒
1.
Sample preparation procedures using octadecyl (C18) extraction disks were developed to obtain accurate and reproducible results for determinations of clenbuterol (20 μg per dose) and levothyroxine (100 μg per dose) in dissolution media of solid oral dosage forms. Preconcentration of samples allowed final concentrations of 1.1 μg/ml of clenbuterol and 4.0 μg/ml of levothyroxine to be reached prior to CE analysis. The results obtained by CE were in good agreement with those of HPLC. The precision of the migration time, peak area, peak height and accuracy were determined in both intea-day (n = 6) and inter-day (n =18) assays. Linearity was demonstrated over the ranges 0.5–80.0 μg/ml of clenbuterol and 1.0–30.0 μg/ml of levothyroxine. The mean recoveries were higher than 94.0%, ranging from 50 to 125% levels with respect to dose potencies. The proposed methodology may be generally applied to determine drugs at ng/ml concentrations.  相似文献   
2.
A capillary electrophoresis method using CDs for quality control of esomeprazole (ESO) in terms of enantiomeric purity and related substances in raw material and pellets was developed. ESO is the S‐enantiomer of omeprazole (OMZ). Several parameters were evaluated, including type and concentration of buffer and CD, concentration of additives and electrolyte pH. Resolution between the enantiomers of OMZ obtained for each parameter tested was calculated and the presence of the main related substance such as OMZ sulfone was carefully monitored. The optimized system consisted of 100 mM Tris‐phosphate buffer pH 2.5 with 20 mM 2‐hydroxypropyl‐β‐CD, 1 mM sodium dithionite, temperature at 15°C, voltage at 28 kV, and UV detection at 301 nm. Once optimized, the electrophoretic system was validated according to ICH guidelines. The limits of detection and quantification for R‐OMZ were 0.6 μg/mL (0.06% w/w of ESO) and 2.0 μg/mL (0.2% w/w of ESO), respectively. A mean concentration of R‐OMZ <0.2% limit established by the United States Pharmacopeia (USP) was found in the raw material and six‐pellet samples of ESO. No other impurities were found in the samples under these conditions. Therefore, the developed method was found to be appropriate not only for enantiomeric quality control of ESO but also for the analysis of ESO and the main related substance in raw material and pharmaceutical formulations as well as for stability indicating studies.  相似文献   
3.
Pristine and WO3 decorated TiO2 nanorods (NRs) were synthesised to investigate n-n-type heterojunction gas sensing properties. TiO2 NRs were fabricated via hydrothermal method on fluorine-doped tin oxide coated glass (FTO) substrates. Then, tungsten was sputtered on the TiO2 NRs and thermally oxidised to obtain WO3 nanoparticles. The heterostructure was characterised by X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive X-ray (EDX) spectroscopy. Fabricated sensor devices were exposed to VOCs such as toluene, xylene, acetone and ethanol, and humidity at different operation temperatures. Experimental results demonstrated that the heterostructure has better sensor response toward ethanol at 200 °C. Enhanced sensing properties are attributed to the heterojunction formation by decorating TiO2 NRs with WO3.  相似文献   
4.
A mixed‐polymeric electrokinetic chromatography system has been developed for the simultaneous determination of a contaminant like oversulfated condroitin sulfate (OSCS) and impurities expressed as dermatan (Der) in heparin (Hep) samples. The EKC system consisted of 0.5% w/v polymeric β‐CD, 0.4% w/v tetronic® 1107 and 400 mM tris‐phosphate buffer at pH 3.5. The optimized electrophoretic conditions included the use of an uncoated‐silica capillary of 50 cm of total length and 75 μm id, an applied voltage of ?7 kV, a temperature of 30°C and 200 nm UV‐detection. The highly sensitive method developed showed low values of LOD, 0.07% w/w (0.07 μg/mL) (OSCS) and 0.1% w/w (0.1 μg/mL) (Der), and values of LOQ 0.2% w/w (0.2 μg/mL) (OSCS) and 0.3% w/w (0.3 μg/mL) (Der) with a concentration level of Hep sample as low as 0.1 mg/mL. Additional parameters of validation such as specificity, linearity, accuracy, and robustness were evaluated according to international guidelines. Owing to its simplicity, high sensitivity, and reliability, the proposed method can be an advantageous alternative to the traditional methodologies for the analysis of Hep in raw material and specially in finished products because of the low amounts of Hep sample required.  相似文献   
5.
In this study, methanol extracts (MEs) and essential oil (EO) of Angelica purpurascens (Avé-Lall.) Gill obtained from different parts (root, stem, leaf, and seed) were evaluated in terms of antioxidant activity, total phenolics, compositions of phenolic compound, and essential oil with the methods of 2,2-azino-bis(3ethylbenzo-thiazoline-6-sulfonic acid (ABTS•+), 2,2-diphenyl-1-picrylhydrazil (DPPH•) radical scavenging activities, and ferric reducing/antioxidant power (FRAP), the Folin–Ciocalteu, liquid chromatography−tandem mass spectrometry (LC−MS/MS), and gas chromatography-mass spectrometry (GC−MS), respectively. The root extract of A. purpurascens exhibited the highest ABTS•+, DPPH•, and FRAP activities (IC50: 0.05 ± 0.0001 mg/mL, IC50: 0.06 ± 0.002 mg/mL, 821.04 ± 15.96 µM TEAC (Trolox equivalent antioxidant capacity), respectively). Moreover, EO of A. purpurascens root displayed DPPH• scavenging activity (IC50: 2.95 ± 0.084 mg/mL). The root extract had the highest total phenolic content (438.75 ± 16.39 GAE (gallic acid equivalent), µg/mL)). Twenty compounds were identified by LC−MS/MS. The most abundant phenolics were ferulic acid (244.39 ± 15.64 μg/g extract), benzoic acid (138.18 ± 8.84 μg/g extract), oleuropein (78.04 ± 4.99 μg/g extract), and rutin (31.21 ± 2.00 μg/g extract) in seed, stem, root, and leaf extracts, respectively. According to the GC−MS analysis, the major components were determined as α-bisabolol (22.93%), cubebol (14.39%), α-pinene (11.63%), and α-limonene (9.41%) among 29 compounds. Consequently, the MEs and EO of A. purpurascens can be used as a natural antioxidant source.  相似文献   
6.
Five electrokinetic chromatography systems were compared concerning retention behavior and lipophilicity. Comparison was based on capacity (retention) factors of some steroidal drugs, and on log P(OW) values derived by the aid of reference substances. In all systems the aqueous buffer consisted of phosphate (20 mM, pH 7.5). Two systems had micelles, three systems microdroplets as negatively charged pseudostationary phases. The micelles were formed by sodium dodecyl sulfate (SDS) and sodium cholate, respectively. One microemulsion consisted (as usual) from octane as oil, butanol as cosurfactant and SDS as charged tenside. Two microemulsions were made from biosurfactants (phosphatidylcholine, isopropylmyristate) to better simulate biopartitioning of the drugs. Even for noncharged analytes a change in migration sequence and thus in log P(OW) was observed for the systems consisting of the biosurfactants, compared to the others. For the former systems, log P(OW) derived from the capacity factors agree for all analytes with those obtained from calculation by computer software based on the structure of the drugs, and with experimental data directly obtained from octanol/water partitioning.  相似文献   
7.
8.
A simple and highly sensitive CE–UV method was applied in the determination of l ‐ctrulline, which was developed from an oral formulation for pediatric use. The novel method was based on the analysis of l ‐citrulline for direct ultraviolet detection at 198 nm. The BGE consisted of 10 mM sodium tetraborate and 50 mM SDS at pH 9, and the electrophoretic parameters were optimized. The method was validated in terms of specificity, linearity, LOD, LOQ, precision, accuracy, and robustness. The LOD and LOQ obtained were 1.36 and 4.54 μg/mL, respectively. In addition, the method offers higher sensitivity and specificity compared with the results obtained from HPLC method using UV‐detectors, in which l‐ citrulline needs to be derivatizated. Furthermore, low cost and simplicity of the system allowed the rapid and simple quantitation of l‐ citrulline in the oral formulation for quality control and stability indicated method.  相似文献   
9.
A novel microemulsion based on sodium bis(2-ethylhexyl) sulfosuccinate (AOT) was developed for the simultaneous determination of natural and synthetic estrogens by microemulsion EKC (MEEKC). The microemulsion system consisted of 1.4% w/w AOT, 1.0% w/w octane, 7.0% w/w 1-butanol and 90.6% w/w 20 mM sodium salt of 3-(cyclohexylamino)-2-hydroxy-1-propanesulfonic acid (CAPSO) and 10 mM phosphate buffer at pH 12.5. A baseline resolution in the separation of estrone, 17beta-estradiol, estriol, estradiol 17-hemisuccinate, etinilestradiol, estradiol 3-benzoate, and estradiol 17-valerate was achieved in comparison to the traditional MEEKC system with SDS in less than 15 min. The optimized electrophoretic conditions included the use of an uncoated-silica capillary of 60 cm of total length and 75 microm id, an applied voltage of 25 kV, a temperature of 25 degrees C and 214 UV-detection. Parameters of validation such as specificity, linearity, accuracy, LOD, LOQ and robustness were evaluated according to international guidelines. Due to its simplicity, accuracy, and reliability, the proposed method can be an advantageous alternative to the traditional methodologies for the analysis of natural and synthetic estrogens in different pharmaceutical forms.  相似文献   
10.
Apart from long-known and applied nanostructures like carbon black for tyres or pigments for coatings nanotechnology has created highly sophisticated structures used for nano/molecular electronics,diagnostics,drug delivery, UV-absorbers etc.Often the main question to be solved analytically is the local determination of tiny amounts of chemicals resulting in an ever increasing need for highly sensitive as well as locally resolved techniques.Applications of techniques like mass spectroscopy,transmission el...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号