首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   0篇
化学   11篇
力学   1篇
数学   1篇
物理学   20篇
  2004年   1篇
  1999年   6篇
  1998年   1篇
  1997年   2篇
  1996年   3篇
  1995年   4篇
  1994年   2篇
  1993年   4篇
  1992年   2篇
  1991年   2篇
  1990年   1篇
  1988年   2篇
  1986年   2篇
  1981年   1篇
排序方式: 共有33条查询结果,搜索用时 174 毫秒
1.
An automated system for derivaatization was coupled on-line with solid-phase extraction-gas-chromatography (SPE-GC). The system was optimized for the determination of phenol and chlorinated phenols in aqueous samples. The test analytes were acetylated with acetic anhydride; proper buffering of the sample was a critical factor. Next, the phenol acetates were enriched on a SPE cartridge and transferred to a GC; two appraoaches were studied. In the first approach, the derivatives were enriched on disposable C18 cartridges (ASPEC type) and desorbed with methylacetate. Aan aliquot of the final eluate was injected on-line the GC by means of a loop-type interface. In the second approach, trace enrichment was performed on 10 × 2 mm i.d. LC-type precolumn packed with polystyrenedivinylbenzene copolymer (PLRP-S) this precolumn was dried with a mitrogen purge and the phenol acetates were desorbed with ethyl acetate which was injectedon-line into the retention gap of the GC under partially concurrent solvent evaporation (PCSE) conditions. The Derivatization-SPE-GC system which was based on the loop-type interface has the advantage of simplicity and easy operation, the main drawback is the impossibility to determine phenol acetates which elute prior to trichlorophenol acetates. With the derivatization-SPE-GC approach using PCSE-based desorption, even the most volatile analyte of the test series, phenol acetate, can be determined successfully. The entire procedure, including the derivatization step, was fully automated and integrated in one set-up. The precision data for the integrated on-line derivatization-SP-FID system were fully satisfactory, with RSD values of 1–12 % at the 1 μg/1 level. When a sample volume of 2.2 ml was analyzed, The detection limits for the chlorinated phenol acetates were in the 0.1–0.3 μg/1 range.  相似文献   
2.
3.
4.
5.
A method for the detection of oxidized, reduced and protein-bound glutathione in eye lenses has been developed. Homogenized lens samples are deproteinated with acetonitrile and perchloric acid. Protein-bound glutathione is reduced by 1,4-dithiothreitol. Separation of the different forms of glutathione and dithiothreitol is performed by ion-pair reversed-phase high-performance liquid chromatography with sodium octylsulphate as the ion-pairing agent. The compounds are detected amperometrically using on-line-generated bromine, which oxidizes thiols and disulphides. In this way two samples can be analysed in triplicate in a single day. The lower detection limits are 80 and 48 nmol per gram wet lens for reduced and oxidized glutathione, respectively. The amounts of free reduced and protein-bound glutathione in calf lenses, determined with this method, are 6.8 +/- 0.4 and 0.96 +/- 0.03 mumol per gram wet lens, respectively. That of oxidized glutathione is less than 0.048 mumol per gram wet lens.  相似文献   
6.
7.
Fast atom bombardment, combined with high-energy collision-induced tandem mass spectrometry, has been used to investigate gas-phase metal-ion interactions with captopril, enalaprilat and lisinopril, all angiotensin-converting enzyme inhibitors.Suggestions for the location of metal-binding sites are presented. For captopril, metal binding occurs most likely at both the sulphur and the nitrogen atom. For enalaprilat and lisinopril, binding preferably occurs at the amine nitrogen. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
8.
An overview is presented of methods currently in use to combine the preparation of aqueous samples on-line with capillary gas chromatography. Two approaches can be distinguished: heartcut-orientated reversed-phase liquid chromatography-gas chromatography (GC) and analyte-isolation-orientated analyte extraction-GC. These approaches either use techniques in which water is directly introduced onto the GC column, or an indirect approach in which water is eliminated, i.e., by solid-phase extraction, solid-phase microextraction or liquid-liquid extraction, prior to introduction of the analytes onto the GC column. The latter type of approach is much more successful and user friendly, and many applications have been reported.  相似文献   
9.
10.
Plant sterols (PS) are very stable molecules but may undergo oxidation due to the presence of a double bond in the ring structure. In order to assess whether this occurs during heating and storage, an analytical procedure was developed for the determination of concentration levels and identity of PS oxidation products in functional food ingredients and products. The method is based on cold saponification, solvent extraction of unsaponifiables, isolation of sterol oxidation products by means of liquid chromatography, and final analysis by gas chromatography (GC) with flame ionization detection. Identification of the key PS oxidation products was performed by means of GC-mass spectrometry (GC-MS). Isotope dilution MS was used to verify the absence of the formation of potential artifacts by the method. The method described is applicable to spreads (containing 20-65% water), oils, sterol esters, pure sterols, and fat extracts from food. The between-day reproducibility of the total content of sterol oxidation products in control samples sample was 8%, and of individual sterol oxidation products, 6-15%. The recovery of sterol oxidation products was 91%. The limit of detection was 0.1 mg/kg.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号