首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
化学   5篇
数学   1篇
物理学   14篇
  2006年   1篇
  2002年   1篇
  2001年   1篇
  2000年   2篇
  1999年   3篇
  1996年   2篇
  1994年   1篇
  1993年   2篇
  1992年   1篇
  1988年   1篇
  1987年   3篇
  1986年   1篇
  1984年   1篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
A polarization variant of an intracavity laser spectrometer based on the competition of beams in an argon ion laser, radiating a number of narrow lines in the 275 to 529 nm spectral range, is proposed and described for the spectral analysis of liquid samples, having broad absorption bands, mainly biomolecules in solutions. By careful optimization of the operating conditions, a procedure has been established that results in a minimal measurable absorbance decreased up to 10(-5) units of optical density. The examined spectrometer provides a wide dynamic range of analysis. A determination of trace contents of amino acids in methanol were carried out.  相似文献   
2.
3.
The fast isocratic narrow-bore reversed-phase high-performance liquid chromatographic method employing fluorescence detection is described for the precise reproducible simultaneous measurement of total homocysteine, cysteine and glutathione in human blood. Sample preparation involves conversion of disulfides to free thiols with triphenylphosphine, precipitation of proteins with sulfosalicylic acid, and conjugation of thiols with monobromobimane. Optimized sample preparation conditions as well as chromatographic conditions allowed to obtain reliable quantitative results within the concentration range corresponding to the levels of these thiols in human blood in norm and pathology. The detection limit was approximately 70 amol for all labeled aminothiols. The proposed method for these compounds analysis includes simple sample preparation, high selectivity, good linearity (r2>0.998), high reproducibility (within-run precision for derivatized aminothiol peaks area RSD<1.8% for three times consequently injected sample); high reliability and the small sample volume (1 microl) required for analysis make it suitable for clinical studies.  相似文献   
4.
This is an initial report to propose a novel approach in high-performance capillary electrophoresis (HPCE) for the direct detection of compounds without natural absorbance in the UV and visible spectral range, such as amino acids and carbohydrates. A refractometry detector with the 2 nl cell (Applied Systems, Minsk, Belarus) was employed to identify amino acids and carbohydrates without derivatization. The first results are provided on separation of seven free amino acids in the phosphate running buffer and three free carbohydrates in the borate-sodium dodecyl sulfate running buffer and detection by refractometer. Fused capillaries of 50 or 75 microm internal diameter and separation voltage (10-23 kV) were applied. Detection limits ranged typically from 10 to 100 fmol and the response was linear over two orders of magnitude for most of the amino acids and carbohydrates. The HPCE system demonstrated good long-term stability and reproducibility with a relative standard deviation, less than 5% for the migration time (n=10).  相似文献   
5.
A polarization variant of an intracavity laser spectrometer based on the competition of beams in an argon ion laser, radiating a number of narrow lines in the 275 to 529 nm spectral range, is proposed and described for the spectral analysis of liquid samples, having broad absorption bands, mainly biomolecules in solutions. By careful optimization of the operating conditions, a procedure has been established that results in a minimal measurable absorbance decreased up to 10–5 units of optical density. The examined spectrometer provides a wide dynamic range of analysis. A determination of trace contents of amino acids in methanol were carried out.  相似文献   
6.
Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) has been used to determine the mass of a double-stranded 500 base-pair (bp) polymerase chain reaction (PCR) product with an average theoretical mass of the blunt-ended (i.e. unadenylated) species of 308 859.35 Da. The PCR product was generated from the linearized bacteriophage Lambda genome which is a double-stranded template. Utilization of ethanol precipitation in tandem with a rapid microdialysis step to purify and desalt the PCR product was crucial to obtain a precise mass measurement. The PCR product (0.8 pmol/μL) was electrosprayed from a solution containing 75% acetonitrile, 25 mM piperidine, and 25 mM imidazole and was infused at a rate of 200 nL/min. The average molecular mass and the corresponding precision were determined using the charge-states ranging from 172 to 235 net negative charges. The experimental mass and corresponding precision (reported as the 95% confidence interval of the mean) was 309 406 +/- 27 Da (87 ppm). The mass accuracy was compromised due to the fact that the PCR generates multiple products when using Taq polymerase due to the non-template directed 3'-adenylation. This results in a mixture of three PCR products with nearly identical mass (i.e. blunt-ended, mono-adenylated and di-adenylated) with unknown relative abundances that were not resolved in the spectrum. Thus, the experimental mass will be a weighted average of the three species which, under our experimental conditions, reflects a nearly equal concentration of the mono- and di-adenylated species. This report demonstrates that precise mass measurements of PCR products up to 309 kDa (500 bp) can be routinely obtained by ESI-FTICR requiring low femtomole amounts. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
7.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
8.
9.
This is the report of Heavy Ion Physics and Quark-Gluon Plasma at WHEPP-09 which was part of Working Group-4. Discussion and work on some aspects of quark-gluon plasma believed to have created in heavy-ion collisions and in early Universe are reported.  相似文献   
10.
AP Balachandran 《Pramana》2002,59(2):359-368
We review certain emergent notions on the nature of space-time from noncommutative geometry and their radical implications. These ideas of space-time are suggested from developments in fuzzy physics, string theory, and deformation quantization. The review focuses on the ideas coming from fuzzy physics. We find models of quantum space-time like fuzzy S 4 on which states cannot be localized, but which fluctuate into other manifolds like CP3. New uncertainty principles concerning such lack of localizability on quantum space-times are formulated. Such investigations show the possibility of formulating and answering questions like the probability of finding a point of a quantum manifold in a state localized on another one. Additional striking possibilities indicated by these developments is the (generic) failure of CPT theorem and the conventional spin-statistics connection. They even suggest that Planck’s ‘constant’ may not be a constant, but an operator which does not commute with all observables. All these novel possibilities arise within the rules of conventional quantum physics, and with no serious input from gravity physics.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号