首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   79篇
  免费   3篇
  国内免费   11篇
化学   90篇
力学   1篇
物理学   2篇
  2023年   1篇
  2022年   2篇
  2021年   2篇
  2020年   6篇
  2019年   4篇
  2018年   3篇
  2016年   6篇
  2015年   2篇
  2014年   6篇
  2013年   7篇
  2012年   12篇
  2011年   12篇
  2010年   3篇
  2009年   2篇
  2008年   3篇
  2007年   5篇
  2006年   5篇
  2005年   2篇
  2004年   2篇
  2003年   6篇
  2002年   1篇
  1986年   1篇
排序方式: 共有93条查询结果,搜索用时 15 毫秒
1.
A rapid DNA analysis has been developed based on a fluorescence intensity change of a molecular beacon in a PDMS microfluidic channel. Recently, we reported a new analytical method of DNA hybridization involving a PDMS microfluidic sensor using fluorescence energy transfer (FRET). However, there are some limitations in its application to real DNA samples because the target DNA must be labelled with a suitable fluorescent dye. To resolve this problem, we have developed a new DNA microfluidic sensor using a molecular beacon. By monitoring the change in the restored fluorescence intensity along the channel length, it is possible to rapidly detect any hybridization of the molecular beacon to the target DNA. In this case, the target DNA does not need to be labelled. Our experimental results demonstrate that this microfluidic sensor using a molecular beacon is a promising diagnostic tool for rapid DNA hybridization analysis.  相似文献   
2.
Yao B  Luo G  Wang L  Gao Y  Lei G  Ren K  Chen L  Wang Y  Hu Y  Qiu Y 《Lab on a chip》2005,5(10):1041-1047
A simply fabricated microfluidic device using a green organic light emitting diode (OLED) and thin film interference filter as integrated excitation source is presented and applied to fluorescence detection of proteins. A layer-by-layer compact system consisting of glass/PDMS microchip, pinhole, excitation filter and OLED is designed and equipped with a coaxial optical fiber and for fluorescence detection a 300 microm thick excitation filter is employed for eliminating nearly 80% of the unwanted light emitted by OLEDs which has overlaped with the fluorescence spectrum of the dyes. The distance between OLED illuminant and microchannels is limited to approximately 1 mm for sensitive detection. The achieved fluorescence signal of 300 microM Rhodamine 6G is about 13 times as high as that without the excitation filter and 3.5 times the result of a perpendicular detection structure. This system has been used for fluorescence detection of Rhodamine 6G, Alexa 532 and BSA conjugates in 4% linear polyacrymide (LPA) buffer (in 1 x TBE, pH 8.3) and 1.4 fmol and 35 fmol mass detection limits at 0.7 nl injection volume for Alexa and Rhodamine dye have been obtained, respectively.  相似文献   
3.
4.
This paper presents a novel paper‐based analytical device based on the colorimetric paper assays through its light reflectance. The device is portable, low cost (<20 dollars), and lightweight (only 176 g) that is available to assess the cost‐effectiveness and appropriateness of the original health care or on‐site detection information. Based on the light reflectance principle, the signal can be obtained directly, stably and user‐friendly in our device. We demonstrated the utility and broad applicability of this technique with measurements of different biological and pollution target samples (BSA, glucose, Fe, and nitrite). Moreover, the real samples of Fe (II) and nitrite in the local tap water were successfully analyzed, and compared with the standard UV absorption method, the quantitative results showed good performance, reproducibility, and reliability. This device could provide quantitative information very conveniently and show great potential to broad fields of resource‐limited analysis, medical diagnostics, and on‐site environmental detection.  相似文献   
5.
The residues and abuse of antibiotics have seriously endangered ecological balance and human health; meanwhile, antibiotics determination is very difficult because of their low levels and multiple categories in complicated matrices. Appropriate sample pretreatment is usually imperative to enrich (ultra)trace antibiotics and eliminate matrix interference prior to chromatographic analysis. Dispersive liquid-liquid microextraction (DLLME) has become an ideal pretreatment technique owing to its simplicity, effectiveness, low-consumption, etc. In this work, an ultrasonic-assisted DLLME (UA-DLLME) was developed for the simultaneous extraction of seven sulfonamides (SAs) antibiotics in environmental water and seafood samples coupled with HPLC-DAD determination. Several parameters affecting UA-DLLME efficiency were systematically optimized, and consequently the SAs were separated and detected within 14.5 min. The obtained limits of detection (LODs) and limits of quantification (LOQs) ranged from 0.7–7.8 μg/L and 2.4–26.0 μg/L for three water samples (seawater, aquaculture wastewater and lake water) and two seafood samples (pomfrets and shrimps). High recoveries (80.0–116.0%) with low relative standard deviations (0.1–8.1%) were achieved for all the tested samples at three spiked levels. Notably, sulfadimethoxine was found at 24.49 μg/L in one seawater sample. The facile, robust and benign DLLME-HPLC method demonstrated promising perspectives for multiresidue analysis of antibiotics.  相似文献   
6.
近年来,微流控纸芯片由于低成本、便携化、检测快等优点,在需要快速检测的环境分析领域中展现出了巨大的应用前景.该综述从微流控纸芯片在环境分析中的应用角度,总结归纳了微流控纸芯片在环境分析中的最新研究进展,并展望了其在未来的发展趋势与挑战.论文内容引用150余篇源于科学引文索引(SCI)与中文核心期刊中的相关论文.该综述包...  相似文献   
7.
微纳尺度的研究是微纳米技术的重要组成部分。本文重点对金纳米通道的制备及其在分离分析、传感器等方面的研究和应用作了评述。展望了金纳米通道的应用前景。  相似文献   
8.
Chen L  Xu S  Li J 《Chemical Society reviews》2011,40(5):2922-2942
Molecular imprinting technology (MIT) concerns formation of selective sites in a polymer matrix with the memory of a template. Recently, molecularly imprinted polymers (MIPs) have aroused extensive attention and been widely applied in many fields, such as solid-phase extraction, chemical sensors and artificial antibodies owing to their desired selectivity, physical robustness, thermal stability, as well as low cost and easy preparation. With the rapid development of MIT as a research hotspot, it faces a number of challenges, involving biological macromolecule imprinting, heterogeneous binding sites, template leakage, incompatibility with aqueous media, low binding capacity and slow mass transfer, which restricts its applications in various aspects. This critical review briefly reviews the current status of MIT, particular emphasis on significant progresses of novel imprinting methods, some challenges and effective strategies for MIT, and highlighted applications of MIPs. Finally, some significant attempts in further developing MIT are also proposed (236 references).  相似文献   
9.
A novel electrochemical biosensor based on functionalized polypyrrole (PPy) nanotube arrays modified with a tripeptide (Gly-Gly-His) proved to be highly effective for electrochemical analysis of copper ions (Cu2+). The vertically oriented PPy nanotube arrays were electropolymerized by using modified zinc oxide (ZnO) nanowire arrays as templates which were electrodeposited on indium–tin oxide (ITO) coated glass substrates. The electrodes were functionalized by appending pyrrole-α-carboxylic acid onto the surface of polypyrrole nanotube arrays by electrochemical polymerization. The carboxylic groups of the polymer were covalently coupled with the amine groups of the tripeptide, and its structural features were confirmed by attenuated total reflection infrared (ATR-IR) spectroscopy. The tripeptide modified PPy nanotube arrays electrode was used for the electrochemical analysis of various trace copper ions by square wave voltammetry. The electrode was found to be highly sensitive and selective to Cu2+ in the range of 0.1–30 μM. Furthermore, the developed biosensor exhibited a high stability and reproducibility, despite the repeated use of the biosensor electrode.  相似文献   
10.
压电晶体传感器的研究进展   总被引:16,自引:0,他引:16  
本文简要介绍了压电晶体传感器的基本原理,以及基于质量、粘度、电导率变化的溶液分析法。重点介绍了电化学石英晶体微天平(EQCM)、压电生物传感器;对具有很大发展潜力和重要应用价值的串联式压电传感器(SPQC)、串联式表面声波电导传感器(SAW)、液隔电极式压电传感器(ESPS)等也作了简要说明。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号