排序方式: 共有5条查询结果,搜索用时 0 毫秒
1
1.
Two laboratories extensively investigated the use of HPTLC to perform assays on lamivudine-zidovudine, metronidazole, nevirapine, and quinine composite samples. To minimize the effects of differences in analysts' technique, the laboratories conducted the study with automatic sample application devices in conjunction with variable-wavelength scanning densitometers to evaluate the plates. The HPTLC procedures used relatively innocuous, inexpensive, and readily available chromatography solvents used in the Kenyon or the Global Pharma Health Fund Minilabs TLC methods. The use of automatic sample applications in conjunction with variable- wavelength scanning densitometry demonstrated an average repeatability or within-laboratory RSD of 1.90%, with 73% less than 2% and 97% at 2.60% or less, and an average reproducibility or among-laboratory RSD of 2.74%. 相似文献
2.
Nyamweru Bugusu C. Sempombe Joseph Kaale Eliangiringa Layloff Thomas 《平面色谱法杂志一现代薄层色谱法》2014,27(1):47-51
JPC – Journal of Planar Chromatography – Modern TLC - A thin-layer chromatography (TLC) method for the analysis of clotrimazole was developed and validated according to the... 相似文献
3.
This review article discusses the sustainability and robust advantages of planar chromatography that are critical to the successful performance of product quality assessments in resource limited areas including field applications. Because of the robustness and ease of use, the training required for successful performance of the high performance thin layer chromatography (HPTLC) assessments is much lower than that of other technologies with comparable reproducibility such as high performance liquid chromatography (HPLC). Some of the successful applications of planar chromatography in resource limited countries are presented. It should be noted that these planar chromatographic technologies have much lower plate counts and therefore separation power than column technologies such as HPLC and gas liquid chromatography (GLC). However in finished pharmaceutical products there are generally few active ingredients which are assessed making the HPTLC adequate for these analyses. In addition at this time there is a much wider array of detection technologies available for HPLC and GLC. 相似文献
4.
5.
The use of rapid and inexpensive nonlaboratory-based screening tests for drug quality assessments is recommended as a component of a drug quality assurance program in poor resource settings. We have established routine Minilab test procedures to screen product quality and a proficiency testing program to determine the competency of the inspectors and reliability of results. Samples for the proficiency testing were prepared by pulverizing a standard reference tablet of the appropriate drug and making serial dilutions with starch to obtain concentrations of 0, 40, and 100%. The samples, which were labeled only with the drug name and an identifying letter, were given to inspectors for quality screening using Minilab procedures. In round 1 of the proficiency test, only 3 of 28 substandard samples were correctly identified. Round 2 of the proficiency test, which was administered after a performance qualification test for the analytical method, showed much improvement: 19 of 27 substandard drugs were correctly identified, while 5 out of 9 inspectors made the correct inference on the quality of 45 samples. However, in both rounds, 2 inspectors failed to identify substandard samples, indicating that their technical competencies need to be improved for the reliability of the results. Although the thin-layer chromatography screening methods provide a rapid means for drug quality assessment, they need to be put in the hands of competent users. The inclusion of a proficiency test in the screening program provides a measure of determining competency of the personnel and reliability of the results. 相似文献
1