排序方式: 共有110条查询结果,搜索用时 15 毫秒
1.
Ksenia Pumpor Elisabeth Windeisen Klaus Burger 《Journal of heterocyclic chemistry》2003,40(3):435-442
The synthesis of heterocyclic α‐mercapto acids starting from (RS)‐thiomalic acid using hexafluoroacetone as protecting and activating agent is described. The new compounds are useful building blocks for peptide and depsipeptide modification as well as for drug design. 相似文献
2.
Ksenia Shilyaeva Nils Elander Evgeny Yarevsky 《International journal of quantum chemistry》2007,107(6):1301-1315
Peaks in collision cross sections are often interpreted as resonances. The complex dilation method, as well as other methods relying on analytic continuation of the scattering formalism, can be used to clarify whether these structures are true resonances in the sense that they are poles of the S‐matrix and the associated Green function. The performance of the Mittag–Leffler expansion and T‐matrix Green function expansion methods are formally and computationally compared. The two methods are applied to two model potentials. Eigenenergies, s‐wave residues, and cross sections are computed with both methods. The resonance contributions to the cross sections are further analyzed by removing the residue contributions from the Mittag–Leffler and Green function expansion sums, respectively. It is suggested that the contribution of a resonance to a cross section should be defined through its S‐matrix residue. © 2006 Wiley Periodicals, Inc. Int J Quantum Chem, 2007 相似文献
3.
Electron ionization (EI) mass spectra of 46 compounds from several different compound classes were measured. Their molecular ion abundances were compared as obtained with 70‐eV EI, with low eV EI (such as 14 eV), and with EI mass spectra of vibrationally cold molecules in supersonic molecular beams (Cold EI). We further compared these mass spectra in their National Institute of Standards and Technology (NIST) library identification probabilities. We found that
- Low eV EI is not a soft ionization method, and it has little or no influence on the molecular ion relative abundances for large molecules and those with weak or no molecular ions.
- Low eV EI for compounds with abundant or dominant molecular ions in their 70 eV mass spectra results in the reduction of low mass fragment ions abundances thereby reducing their NIST library identification probabilities thus rarely justifies its use in real‐world applications.
- Cold EI significantly enhances the relative abundance of the molecular ions particularly for large compounds; yet, it retains the low mass fragment ions; hence, Cold EI mass spectra can be effectively identified by the NIST library.
- Different standard EI ion sources provide different 70 eV EI mass spectra. Among the Agilent technologies ion sources, the “Extractor” exhibits relatively abundant molecular ions compared with the “Inert” ion source, while the “High efficiency source” (HES) provides mass spectra with depleted molecular ions compared with the “Inert” ion source or NIST library mass spectra.
4.
5.
6.
Eremina Julia A. Smirnova Ksenia S. Lider Elizaveta V. Klyushova Lyubov’ S. Sheven’ Dmitriy G. Potkin Vladimir I. 《Transition Metal Chemistry》2022,47(1):19-30
Transition Metal Chemistry - In this study, Ni(II) and Co(II) complexes [Co(H2O)2L2] (1), [Ni(H2O)2L2] (2), [Co(phen)L2] (3), [Ni(phen)L2]·2H2O·EtOH (4·2H2O), and... 相似文献
7.
We demonstrate the controlled preparation of Er‐ and Eu‐doped GaP‐oxide porous composites. The fabrication procedure entails the use of porous semiconductor templates and the impregnation of rare earth ions from a rare earth salt solution in alcohol and thermal treatment. The composites exhibit strong green and red emission that comes from finely dispersed ErPO4 and EuPO4 oxide submicron phases in the composite. These materials may prove useful in future generations of optoelectronic and photonic devices. (© 2007 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim) 相似文献
8.
Denis A. Knyazkov Artëm M. Dmitriev Oleg P. Korobeinichev Ksenia N. Osipova Gianmaria Pio Andrey G. Shmakov Ernesto Salzano 《Proceedings of the Combustion Institute》2021,38(2):2467-2475
The knowledge of the combustion chemistry of oxygenated fuels is essential for the development of detailed kinetic mechanisms suitable for the combustion processes involving biofuels. Moreover, epoxidized olefins, are increasingly used as chemical intermediates or as bulk chemicals. Nevertheless, a dearth of data for their reactivity in the oxidative environment can be observed in the current literature. This study reports the experimental and the model characterization of the flame structure of propylene oxide at stoichiometric and fuel-rich conditions at atmospheric pressure. To this aim, the species mole fractions in three premixed flames stabilized on a flat-flame burner have been quantitatively measured by using the flame sampling molecular beam mass spectrometry. Three chemical kinetic mechanisms retrieved from the current literature involving propylene oxide chemistry have been validated against the novel experimental data. In general, the predictions appeared to be in satisfactory agreement with measurements except for acetaldehyde and ketene. The rate of production analysis in the flame has shown that the discrepancies observed for these species are related basically to the incorrect ratio between the rates of primary reaction pathways of propylene oxide destruction. 相似文献
9.
Wong SY Moskowitz JS Veselinovic J Rosario RA Timachova K Blaisse MR Fuller RC Klibanov AM Hammond PT 《Journal of the American Chemical Society》2010,132(50):17840-17848
Here we present a new bifunctional layer-by-layer (LbL) construct made by combining a permanent microbicidal polyelectrolyte multilayered (PEM) base film with a hydrolytically degradable PEM top film that offers controlled and localized delivery of therapeutics. Two degradable film architectures are presented: (1) bolus release of an antibiotic (gentamicin) to eradicate initial infection at the implant site, or (2) sustained delivery of an anti-inflammatory drug (diclofenac) to cope with inflammation at the site of implantation due to tissue injury. Each degradable film was built on top of a permanent base film that imparts the implantable device surface with microbicidal functionality that prevents the formation of biofilms. Controlled-delivery of gentamicin was demonstrated over hours and that of diclofenac over days. Both drugs retained their efficacy upon release. The permanent microbicidal base film was biocompatible with A549 epithelial cancer cells and MC3T3-E1 osteoprogenitor cells, while also preventing bacteria attachment from turbid media for the entire duration of the two weeks studied. The microbicidal base film retains its functionality after the biodegradable films have completely degraded. The versatility of these PEM films and their ability to prevent biofilm formation make them attractive as coatings for implantable devices. 相似文献
10.
Dolgaleva K Malacarne A Tannouri P Fernandes LA Grenier JR Aitchison JS Azaña J Morandotti R Herman PR Marques PV 《Optics letters》2011,36(22):4416-4418
We experimentally demonstrate the first integrated temporal Fourier transformer based on a linearly chirped Bragg grating waveguide written in silica glass with a femtosecond laser. The operation is based on mapping the energy spectrum of the input optical signal to the output temporal waveform by making use of first-order chromatic dispersion. The device operates in reflection, has a bandwidth of 10 nm, and can be used for incident temporal waveforms as long as 20 ps. Experimental results, obtained through both temporal oscilloscope traces and Fourier transform spectral interferometry, display a successful Fourier transformation of in-phase and out-of-phase pairs of input optical pulses, and demonstrate the correct functionality of the device for both amplitude and phase of the temporal output. 相似文献