全文获取类型
收费全文 | 86篇 |
免费 | 3篇 |
国内免费 | 1篇 |
专业分类
化学 | 58篇 |
力学 | 2篇 |
数学 | 24篇 |
物理学 | 6篇 |
出版年
2022年 | 1篇 |
2021年 | 1篇 |
2019年 | 3篇 |
2018年 | 1篇 |
2016年 | 3篇 |
2015年 | 2篇 |
2014年 | 3篇 |
2013年 | 5篇 |
2012年 | 8篇 |
2011年 | 8篇 |
2010年 | 7篇 |
2009年 | 2篇 |
2008年 | 4篇 |
2007年 | 3篇 |
2006年 | 4篇 |
2005年 | 5篇 |
2004年 | 4篇 |
2003年 | 5篇 |
2002年 | 5篇 |
2001年 | 3篇 |
2000年 | 2篇 |
1998年 | 2篇 |
1997年 | 2篇 |
1996年 | 2篇 |
1995年 | 2篇 |
1994年 | 1篇 |
1991年 | 2篇 |
排序方式: 共有90条查询结果,搜索用时 15 毫秒
1.
Strategically designed sample composition (SSC) is a new technique that decreases the number of analytical determinations needed in routine screening to as few as the number of original sample specimens while providing information that is specific to them. Although this new technique has been applied to environmental studies, this paper describes its first application to food safety studies. Contamination of milk samples with polychlorinated biphenyls (PCBs) was chosen as a case study to show the usefulness and potential of the SSC technique with a fast analytical procedure that involves saponification of the samples and solid-phase microextraction of the PCBs. A total of 20 sample specimens can be analyzed in 11 determinations with excellent predictions of the positive samples and the concentration levels of the contaminants. The robustness of the strategy was investigated and demonstrated. 相似文献
2.
An effective multiresidual method for the trace analysis of fifteen compounds from a diverse group of pesticides, polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyl (PCBs) and polybrominated biphenyl (PBBs) in aquaculture feed is described. The analytical procedure is based on the matrix solid-phase dispersion (MSPD) of feed sample and subsequent elution with hexane. The MSPD process was evaluated using an asymmetrical experimental design 2(3)3(2)//9. Factors such as C18 sorbent amount, kind of adsorbents, solvent volume and elution mode were considered. The results suggest that the operational MSPD conditions are elution with pressure, 1 g of C18, basic alumina as adsorbent and 30 mL of hexane. The overall method including MSPD procedure and GC coupled to mass spectrometry (MS/MS) has been applied to several samples of aquaculture feed and marine species. Precision and accuracy of the analytical method were determined using the reference material from the International Atomic Energy Agency (IAEA-406), showing a good agreement to the referenced values. 相似文献
3.
Carro María J. Ortiz-Caraballo Carmen 《Journal of Fourier Analysis and Applications》2019,25(1):145-166
Journal of Fourier Analysis and Applications - We prove a weighted estimate for the disc multiplier, acting on radial functions, at the extreme points $$p_{-}=\frac{2n}{n+1}$$ , extending the... 相似文献
4.
D. García-Rodríguez A. M. Carro R. Cela R. A. Lorenzo 《Analytical and bioanalytical chemistry》2010,398(2):1005-1016
A microwave-assisted extraction method followed by clean-up with solid-phase extraction (SPE) combined with large-volume injection
gas chromatography–tandem mass spectrometry (LVI-GC-MS/MS) for the analysis of 17 pesticides in wild and aquaculture edible
seaweeds has been developed. An experimental central composite design was employed to evaluate the effects of the main variables
potentially affecting the extraction (temperature, time, and solvent volume) and to optimize the process. The most effective
microwave extraction conditions were achieved at 125 °C and 12 min with 24 mL of hexane/ethyl acetate (80:20). SPE clean-up
of the extracts with graphitized carbon and Florisil, optimized by means of the experimental design, proved to be efficient
in the removal of matrix interferences. The analytical recoveries were close to 100% for all the analytes, with relative standard
deviations lower than 13%. The limits of detection ranged from 0.3 to 23.1 pg g−1 and the limits of quantification were between 2.3 and 76.9 pg g−1, far below the maximum residue levels established by the European Union for pesticides in seaweed. The results obtained prove
the suitability of the microwave-assisted extraction for the routine analysis of pesticides in aquaculture and wild seaweed
samples. 相似文献
5.
We develop an extension of the Transference methods introduced by R. Coifman and G. Weiss and apply it to study the problem
of the restriction of Fourier multipliers between rearrangement invariant spaces, obtaining natural extensions of the classical
de Leeuw’s result and its further extension to maximal Fourier multipliers due to C. Kenig and P. Tomas. 相似文献
6.
Experimental design for optimization of microwave-assisted extraction of benzodiazepines in human plasma 总被引:1,自引:0,他引:1
P. Fernández C. Vázquez R. A. Lorenzo A. M. Carro I. Álvarez P. Cabarcos 《Analytical and bioanalytical chemistry》2010,397(2):677-685
A simple and fast microwave-assisted-extraction (MAE) method has been evaluated as an alternative to solid-phase extraction
(SPE) for the determination of six benzodiazepines widely prescribed in European countries (alprazolam, bromazepam, diazepam,
lorazepam, lormetazepam and tetrazepam) in human plasma. For MAE optimization a Doehlert experimental design was used with
extraction time, temperature and solvent volume as influential parameters. A desirability function was employed in addition
to the simultaneous optimization of the MAE conditions. The analysis of variance showed that the solvent volume had a positive
influence on the extraction of all the analytes tested, achieving a statistically significant effect. Also, the extraction
time had a statistically significant effect on the extraction of four benzodiazepines. The selected MAE conditions—89 °C,
13 min and 8 mL of chloroform/2-propanol (4:1, v/v)—led to recoveries between 89.8 ± 0.3 and 102.1 ± 5.2% for benzodiazepines
using a high performance liquid chromatography method coupled with diode-array detection. The comparison of MAE and SPE shows
better results for MAE, with a lower number of steps in handling the sample and greater efficiency. The applicability of MAE
was successfully tested in 27 plasma samples from benzodiazepine users. 相似文献
7.
8.
In this article we obtain the boundedness of the periodic, discrete and ergodic
bilinear Hilbert transform, from
,
where
1$, and $p_3\ge 1$" align="middle" border="0">
. The main techniques are a bilinear version of the transference method of Coifman and Weiss and certain discretization of bilinear operators. In the periodic case, we also obtain the boundedness for
相似文献
9.
Validation and quality control of methylmercury determinations by means of capillary electrophoresis 总被引:1,自引:0,他引:1
Antonia Maria Carro Diaz R. A. Lorenzo-Ferreira R. Cela-Torrijos 《Mikrochimica acta》1996,123(1-4):73-86
Methyl-Hg is one of the most dangerous pollutants in the environment. It is highly toxic and accumulates through the food chain. Tuna fish especially tends to concentrate Hg in the form of methyl-Hg. Quality assurance is a well established routine in analytical laboratories to control the variability of analytical results and to maintain adequate stability, detection power and reproducibility. Capillary electrophoresis (CE) has shown in recent years powerful capabilities for the resolution and analysis of very complex samples. The high resolution and peak capacity characteristics of this technique could be used favourably in speciation studies of organo-Hg compounds. Since the time needed for separation is usually very short in this technique, it lends itself to routine analysis. The application of quality control approaches in the analysis of methyl-Hg in tuna freeze-dried materials using CE is reported. 相似文献
10.
Barbara Benedetti Emanuele Magi Marina Di Carro 《Journal of separation science》2019,42(20):3225-3233
The present paper deals with the multivariate optimization of an extraction‐purification strategy for the determination of phytoestrogens (daidzein, genistein, coumestrol, formononetin, and biochanin A) in soy‐based meat substitutes by high performance liquid chromatography with tandem mass spectrometry. For a reliable quantitation of these new concerning compounds in such a complex matrix, recovery and matrix effect must be carefully evaluated. Therefore, two sequential experimental designs were used to optimize the sample‐pretreatment of soy‐based burgers: the chosen technique was the quick, easy, cheap, effective, rugged and safe methodology, which does not require any particular facility or instrumentation. Thanks to the first screening design (Plackett‐Burman), the significant factors influencing the studied responses were identified and further investigated through a response surface design (Box‐Behnken). The optimal values of the variables (volume of extraction solvent mix/sample mass ratio and two clean‐up sorbents) led to quantitative recoveries (97–104%) and low ion suppression (matrix effect 60–93%) for all analytes. This optimized method was characterized by low detection limits (0.2–1.5 ng/g) and excellent intraday precision (RSD 2–4%). It was applied to the determination of the considered compounds in several soy‐burgers from the Italian market, detecting low ng/g levels (up to 40 ng/g) of coumestrol, formononetin, and biochanin A, and high concentrations (7.9–78 µg/g) of genistein and daidzein. 相似文献