排序方式: 共有72条查询结果,搜索用时 437 毫秒
1.
Taylor MJ Hunter K Hunter KB Lindsay D Le Bouhellec S 《Journal of chromatography. A》2002,982(2):225-236
A LC-MS-MS method capable of the quantitative determination of a range of pesticide residues present in crude extracts from a variety of fruit and vegetables has been developed. Isocratic LC conditions have been used in conjunction with electrospray ionisation tandem mass spectrometry to detect and identify up to 38 pesticides presented as various mixtures in different matrices. The utility of the method is demonstrated by the analysis of crude extracts, with no sample clean up, from grape, kiwi fruit, strawberry, spinach, lemon, peach and nectarine. Mean recoveries ranging from 63 to 96% with relative standard deviations < 20% were obtained for 30 of the 38 pesticides following analysis of organic produce fortified at concentrations between 0.01 and 0.8 mg/kg. Detected residues were quantified from interpolation against calibration data generated using matrix-matched standards that covered analyte concentration ranges between 0.005 and 0.8 microg/ml. Conditions suitable for the qualitative and quantitative confirmation of residues detected in samples are specified. 相似文献
2.
Kirsty McKay Tara L. Salter Andrew Bowfield James L. Walsh Ian S. Gilmore James W. Bradley 《Journal of the American Society for Mass Spectrometry》2014,25(9):1528-1537
Plasma-based desorption/ionization sources are an important ionization technique for ambient surface analysis mass spectrometry. In this paper, we compare and contrast three competing plasma based desorption/ionization sources: a radio-frequency (rf) plasma needle, a dielectric barrier plasma jet, and a low-temperature plasma probe. The ambient composition of the three sources and their effectiveness at analyzing a range of pharmaceuticals and polymers were assessed. Results show that the background mass spectrum of each source was dominated by air species, with the rf needle producing a richer ion spectrum consisting mainly of ionized water clusters. It was also seen that each source produced different ion fragments of the analytes under investigation: this is thought to be due to different substrate heating, different ion transport mechanisms, and different electric field orientations. The rf needle was found to fragment the analytes least and as a result it was able to detect larger polymer ions than the other sources. Figure
? 相似文献
3.
D. W. Holt Kirsty Denny Terry Lee Atholl Johnston 《Accreditation and quality assurance》2001,6(9-10):405-408
Most medical laboratories measure the immunosuppressive drug cyclosporin using one of a number of commercial immunoassays, or high-performance liquid chromatography (HPLC). The calibration of these assays is based on material supplied by the kit manufacturers or prepared in-house. We have examined inaccuracy for the measurement of cyclosporin in samples spiked to known concentrations and the impact of any inaccuracy on the results for cyclosporin measurement in pooled samples from patients prescribed the drug. The data were from the International Cyclosporin Proficiency Testing Scheme, based on aliquots of cyclosporin-free blood to which known amounts of the drug had been added or aliquots of pooled samples collected from patients receiving cyclosporin. Compared with the results using HPLC, the immunoassays had a median bias which ranged from –4.5% to 8.2% for the spiked samples. When pooled samples from patients were analysed the percentage difference from the measured HPLC value, allowing for assay inaccuracy, was as high as 29.9%. It is concluded that inaccuracy is a factor in between-assay performance for this measurement and that proficiency testing schemes should attempt to put more emphasis on this aspect of assay performance. 相似文献
4.
Dr. M. Laura Soriano Dr. Joseph T. Lenthall Dr. Kirsty M. Anderson Dr. Stephen J. Smith Prof. Jonathan W. Steed 《Chemistry (Weinheim an der Bergstrasse, Germany)》2010,16(35):10818-10831
Treatment of a range of bis(thiourea) ligands with inert organometallic transition‐metal ions gives a number of novel complexes that exhibit unusual ligand binding modes and significantly enhanced anion binding ability. The ruthenium(II) complex [Ru(η6‐p‐cymene)(κS,S′,N‐ L3 ?H)]+ ( 2 b ) possesses juxtaposed four‐ and seven‐membered chelate rings and binds anions as both 1:1 and 2:1 host guest complexes. The pyridyl bis(thiourea) complex [Ru(η6‐p‐cymeme)(κS,S′,Npy‐ L4 )]2+ ( 4 ) binds anions in both 1:1 and 1:2 species, whereas the free ligand is ineffective because of intramolecular NH???N hydrogen bonding. Novel palladium(II) complexes with nine‐ and ten‐membered chelate rings are also reported. 相似文献
5.
6.
Banerji B Conejo-Garcia A McNeill LA McDonough MA Buck MR Hewitson KS Oldham NJ Schofield CJ 《Chemical communications (Cambridge, England)》2005,(43):5438-5440
Cyclic beta-oxocarboxylic acids inhibit factor inhibiting hypoxia-inducible factor via ligation to the active site iron. 相似文献
7.
Stanley CE Clarke N Anderson KM Elder JA Lenthall JT Steed JW 《Chemical communications (Cambridge, England)》2006,(30):3199-3201
A chiral tris(urea) organogelator gels dmso-water and methanol-water mixtures at low weight percent. The formation of the helical gel fibres is partially inhibited by addition of chloride, which is bound by the gelator, resulting in fully crystalline material characterised by X-ray crystallography. 相似文献
8.
Jozef Sochr Katarína Nem
ekov Monika ernicov Kirsty Campbell Viktor Milata Dana Farkaov Jn Labuda 《Electroanalysis》2019,31(10):1961-1968
The synthetic estrogen 17α‐ethinylestradiol (EE2) is an active component of oral contraceptives. It is considered as an endocrine disrupting compound that, once incorporated into an organism, affects the hormonal balance of animals and humans. In this study we characterized the DNA‐EE2 interaction using an electrochemical biosensor and biosensing in solution phase with the double stranded DNA from salmon sperm and deoxyguanosine monophosphate (dGMP). Differential pulse voltammetry method has been applied based on voltammetric anodic responses of the deoxyguanine (dGuo) and deoxyadenine (dAdo) as well as EE2 in the medium of phosphate buffer solution pH 7.0. Binding of EE2 to the nucleobases leads to a decrease of their anodic signals. Association constant for DNA‐EE2 interaction has been estimated to be about 1.1 ? 103 L mol?1 and 1.4 ? 103 L mol?1 for dGuo and dAdo responses, respectively. The association is reversible as indicated by decrease of the EE2 response in pure buffer solution due to leaching of EE2 from the surface attached DNA. The DNA‐EE2 association has been confirmed also by UV‐vis spectrometric experiments. 相似文献
9.
Dr. Safaa M. Kishk Dr. Kirsty J. McLean Dr. Sakshi Sood Darren Smith Jack W.D. Evans Prof. Mohamed A. Helal Prof. Mohamed S. Gomaa Prof. Ismail Salama Prof. Samia M. Mostafa Dr. Luiz Pedro S. de Carvalho Colin W. Levy Prof. Andrew W. Munro Dr. Claire Simons 《ChemistryOpen》2019,8(7):995-1011
The emergence of untreatable drug-resistant strains of Mycobacterium tuberculosis is a major public health problem worldwide, and the identification of new efficient treatments is urgently needed. Mycobacterium tuberculosis cytochrome P450 CYP121A1 is a promising drug target for the treatment of tuberculosis owing to its essential role in mycobacterial growth. Using a rational approach, which includes molecular modelling studies, three series of azole pyrazole derivatives were designed through two synthetic pathways. The synthesized compounds were biologically evaluated for their inhibitory activity towards M. tuberculosis and their protein binding affinity (KD). Series 3 biarylpyrazole imidazole derivatives were the most effective with the isobutyl ( 10 f ) and tert-butyl ( 10 g ) compounds displaying optimal activity (MIC 1.562 μg/mL, KD 0.22 μM ( 10 f ) and 4.81 μM ( 10 g )). The spectroscopic data showed that all the synthesised compounds produced a type II red shift of the heme Soret band indicating either direct binding to heme iron or (where less extensive Soret shifts are observed) putative indirect binding via an interstitial water molecule. Evaluation of biological and physicochemical properties identified the following as requirements for activity: LogP >4, H-bond acceptors/H-bond donors 4/0, number of rotatable bonds 5–6, molecular volume >340 Å3, topological polar surface area <40 Å2. 相似文献
10.
Dickson SJ Paterson MJ Willans CE Anderson KM Steed JW 《Chemistry (Weinheim an der Bergstrasse, Germany)》2008,14(24):7296-7305
The synthesis of a series of ruthenium(II) based anion sensors of the type [Ru(eta(6)-C(6)H(4)MeCHMe(2))Cl(L)(2)][BF(4)] (2) is reported in which ligand L represents a series of substituted pyridinylmethyl-amine derivatives. The carbazole based ligand L(3) exhibits a fluorescent intraligand charge-transfer (ILCT) state that is quenched by ligand-to-metal charge transfer (LMCT) upon coordination to ruthenium in the 1:1 complex [Ru(eta(6)-C(6)H(4)MeCHMe(2))Cl(2)(L(3))] (1 c). The 1:2 complex 2 c is fluorescent, however, and acts as a fluorescent anion sensor because of the mixing of an anion-dependent charge-transfer component into the excited state. The 1:2 complexes of type 2 all exhibit interesting low symmetry (1)H NMR spectra that also are a useful handle on anion complexation. The electronic structures of L(3), 1 c and 2 c have been probed by time-dependent DFT calculations. 相似文献