首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   18篇
  免费   0篇
化学   17篇
物理学   1篇
  2021年   1篇
  2014年   1篇
  2013年   1篇
  2012年   3篇
  2010年   4篇
  2009年   2篇
  2008年   3篇
  2005年   2篇
  1990年   1篇
排序方式: 共有18条查询结果,搜索用时 15 毫秒
1.
A fast and simple chromatographic method to determine biotin in foods is presented. Biotin is extracted using papain (60 degrees C, 1 h). After pH adjustment and filtration, biotin is determined by LC with fluorescence detection using postcolumn reagent avidin-FITC (avidin labeled with fluorescein isothiocyanate). The method has been validated in a large range of products: milk- and soy-based infant formulas, cereals, cocoa-malt beverages, and clinical nutrition products. The method showed recovery rates of 98.1 +/- 5.7% (average +/- SD) in a large range of concentrations. Biotin concentrations determined in infant formula standard reference materials 1846 and 1849 were in agreement with reference values. RSD of repeatability (RSDr) varied from 2.0 to 4.5%, and intermediate reproducibility (RSD(iR)) from 5.8 to 9.4%. LOD and LOQ were 3.0 and 5.0 microg/100 g, respectively. The proposed method is suitable for routine analysis of biotin in fortified foods (infant formulas, infant cereals, cocoa-malt beverages, and clinical nutrition products). It can be used as a faster, more selective, and precise alternative to the classical microbiological determination, and is easily transferable among laboratories.  相似文献   
2.
A selective dopamine determination using a nafion-coated clinoptilolite-modified carbon paste electrode in the presence of ascorbic acid was studied. Both cyclic voltammetry (CV) and differential pulse anodic stripping voltammetry (DPASV) were used for measurements of dopamine. To improve the selectivity of the clinoptilolite-modified carbon paste electrode in presence of a high concentration of ascorbic acid, the electrode surface was coated with nafion membrane. Experimental parameters affecting the determination of dopamine, including the clinoptilolite ratio, nafion membrane thickness, preconcentration time, preconcentration solution pH, stripping solution pH and interferences are discussed. The developed sensor has a wide linear range, a low detection limit, and good stability and reproducibility. The sensor offers a good alternative to existing analytical methods for dopamine, permits a relatively short analysis time, and is simple, selective and inexpensive.  相似文献   
3.
Kilinc E 《Talanta》2005,65(4):876-881
An HPLC-ECD method is described for the indirect determination of the hydroxyl (OH) radical. Fenton's reaction is used to produce OH, which simultaneously attacks phenols (phenol or pyrocatechol) to form the adducts, pyrocatechol or pyrogallic acid. Thus, [OH] quantification is based on the separation and detection of pyrogallic acid and/or pyrocatechol by an isocratic HPLC-ECD method. The quantification of OH is also performed alternatively by a chronoamperometric detection in an electrochemical cell, where simultaneously formed FeIII (Fenton's reaction) combines [FeII(CN)6]4− to produce the Prussian blue (PB) molecules (Fe4III[FeII(CN)6]3). Newly formed PB molecules are then immediately converted to colorless Everitts salt (K4Fe4II[FeII(CN)6]3) with the reduction of the high-spin FeIII to FeII at the surface of a glassy carbon electrode at +0.150 V (versus Ag/AgCl). The calculated concentration of OH during incubation (0.626 ppm) can be detected with negative errors by the HPLC-ECD (0.595 and 0.615 ppm with the errors −5.2 and −1.8%, respectively) and by the chronoamperometric method (0.552 and 0.607 ppm with the errors −11.8 and −3.0%, respectively). For the comparison of the two sets of data, HPLC-ECD method is much more promising.  相似文献   
4.
ABSTRACT

In this study, preconcentration and separation of Cu(II) and Pb(II) ions by using Fe3O4@SiO2@Bacillus pumilis before their determinations by flame atomic absorption spectrometry (FAAS) were investigated. The thermophilic Bacillus pumilis were isolated from Meyremderesi spring, ??rnak, Turkey. Effects of important parameters such as pH, adsorbent amount, eluent type, concentration and volume of eluent and sample volume on magnetic solid phase extraction (MSPE) were examined in details. The preconcentration factors for Cu(II) and Pb(II) ions were calculated as 30 and 40, respectively. The accuracy of the proposed extraction procedure was validated analysing certificated reference materials and addition – recovery tests. The concentration of copper and lead were determined in water samples from Turkey by Flame AAS after application developed preconcentration-separation method.  相似文献   
5.
Cadmium and nickel ions have been preconcentrated on Geobacillus thermoleovorans subsp. stromboliensis, immobilized on Amberlite XAD-4, and were determined by flame atomic absorption spectrometry (FAAS). Parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of solution and the matrix interference effect on retention have been studied, and extraction conditions were optimized. Elution of Cd(II) and Ni(II) from minicolumns was carried out with 1.0 M hydrochloric acid or nitric acid with recoveries from 97 to 100%. The sorption capacity is 0.0373 and 0.0557 mmol g?1 for Cd(II) and Ni(II), respectively. The detection limits were 0.24 μg L?1 for cadmium and 0.3 μg L?1 for nickel. The relative standard deviations of the procedure were below 10%. The procedure was validated by analyzing certified reference materials and applied to the determination of Cd(II) and Ni(II) in natural water and food samples.  相似文献   
6.
A single-laboratory validation study was conducted for a liquid chromatographic/mass spectrometric (LCIMS) method for the simultaneous determination of the free carnitine and total choline in milk-based infant formula and health-care products. The sample preparation used for both carnitine and choline was adapted from AOAC Official Method 999.14, with an acidic and enzymatic hydrolysis of esterified forms of choline. Carnitine and choline were quantified by ion-pair chromatography with single-quadrupole MS detection, using their respective deuterated internal standards. The repeatability relative standard deviation was < or =2.5 and 2.1%, respectively, for carnitine and choline. The intermediate reproducibility relative standard deviation was <4.7 and 2.4%, respectively, for carnitine and choline. The ranges of the average product-specific recoveries were 92-98 and 94-103%, respectively, for carnitine and choline. Choline concentration determined in infant formula reference material SRM 1846 was in agreement with the reference value. The proposed method was compared with the enzymatic methods for a range of products; good correlation (r = 0.99) was obtained, although a significant bias was observed for both analytes. The method, with a short chromatographic run time (7 min), is convenient for routine analysis to enhance analytical throughput and is a good alternative to enzymatic assays.  相似文献   
7.
JPC – Journal of Planar Chromatography – Modern TLC - Simultaneous High-Performance Thin-Layer Chromatographic Determination of Indole Acetic Acid, Indole Butyric Acid, and Absisic Acid...  相似文献   
8.
A fast and simple method to determine vitamin B12 in foods is presented. The method allows, in addition to the determination of added cyanocobalamin, the determination of natural vitamin B12 forms, making it also applicable to nonfortified products, especially those that are milk-based. Vitamin B12 is extracted in sodium acetate buffer in the presence of sodium cyanide (100 degrees C, 30 min). After purification and concentration with an immunoaffinity column, vitamin B12 is determined by liquid chromatography with UV detection (361 nm). The method has been validated in analyses of a large range of products: milk- and soy-based infant formulas, cereals, cocoa beverages, health care products, and polyvitamin premixes. The method showed appropriate performance characteristics: linear response over a large range of concentrations, recovery rates of 100.8 +/- 7.5% (average +/- standard deviation), relative standard deviation of repeatability, RSDr, of 2.1%, and intermediate reproducibility, RSDiR, of 4.3%. Limits of detection and quantitation were 0.10 and 0.30 microg/100 g, respectively, and correlation with the reference microbiological assay was good (R2 = 0.9442). The proposed method is suitable for the routine determination of vitamin B12 in fortified foods, as well as in nonfortified dairy products. It can be used as a faster, more selective, and more precise alternative to the classical microbiological determination.  相似文献   
9.
C(2)-Symmetric two bis(amino alcohol)oxalamides (diamidediols) were synthesized and fully characterized. A new method was developed and successfully applied for the simultaneous preconcentration of both trace and toxic metals in water, by using C(2)-symmetric compounds. Under the optimum experimental conditions (i.e. pH = 10.0 +/- 0.2, 2.75 x 10(-3) mol L(-1) N,N'-bis[(1R)-1-ethyl-2-hydroxyethyl]ethanediamide (DAD1), 1.75 x 10(-3) mol L(-1) N,N'-bis[(1S)-1-benzyl-2-hydroxyethyl]-ethanediamide (DAD2), 0.10% w/v octylphenoxy-polyethoxyethanol (Triton X-114)), calibration graphs were linear in the range of 2.5 - 25.0 ng mL(-1) for Cu and Cd, 5.0 - 25.0 ng mL(-1) for Co and Ni. The enrichment factors were 18, 23, 18 and 20 for Cd, Cu, Co and Ni in the case of DAD1, respectively; 20, 22, 17 and 20 for Cd, Cu, Co and Ni in the case of DAD2. The limits of detection for DAD1 were found to be 0.45, 0.50, 1.25 and 0.60 ng mL(-1) for Cd, Cu, Co and Ni, respectively, and for DAD2 were found to be 0.44, 0.25, 0.60 and 1.55 ng mL(-1) for Cd, Cu, Co and Ni, respectively. The developed method was applied to the determination of Cu, Cd, Co and Ni in water samples and certified reference materials with satisfactory results.  相似文献   
10.
A simple, sensitive, selective, precise and stability-indicating high-performance thin-layer chromatographic (HPTLC) method was developed and applied to human urine for the densitometric determination of sulfanilamide. A mixture of chloroform-ethyl acetate-xylene (2.5: 4.0: 1.0, v/v/v) was used as a mobile phase. The system was found to give compact spots for sulfanilamide (retardation factor, R f = 0.21±0.02). The linear regression analysis data for the calibration plots showed good linear relationship with r 2 = 0.9970 ± 0.0003 and r 2 = 0.9947 ± 0.020 within the concentration range of 50–250 ng per spot and 100–1000 ng per spot with respect to peak area, respectively. The limit of detection (LOD) and quantification (LOQ) were 8 and 25 ng per spot, respectively. Sulfanilamide was subjected to acid and alkali hydrolysis, oxidation, dry heat and wet heat treatment. According to the International Conference on Harmonization (ICH) guidelines the method was validated for precision, recovery and robustness. The ultraviolet (UV) spectra of the degradation products which had different spectra from sulfanilamide were also recorded. The article is published in the original.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号