首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   2篇
数学   2篇
  2009年   2篇
  2007年   2篇
排序方式: 共有4条查询结果,搜索用时 0 毫秒
1
1.
We examine the long-run average availability and cost rate of a maintained system which deteriorates according to a random-shock process. Shocks arrive according to a Poisson process. The system fails whenever the cumulative damage exceeds a given threshold. The system's failures are not self-announcing, hence, failures must be detected via inspections. The system is inspected at periodic or exponentially distributed intervals. Systems are replaced by preventive maintenance or after failure (corrective maintenance), whichever occurs first. When the distribution function of the shock magnitudes belongs to the class of subexponential distributions, we obtain simple approximations for the availability and the cost rate. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   
2.
We examine the limiting average availability of a maintained system that deteriorates due to random shock process and as a response to its usage (wear out). System’s failures are not self-announcing, hence, failures must be detected via inspection. We consider randomly occurring shocks that arrive according to a Poisson process and cumulatively damage the system. Two models are considered: in Model 1 the shock and wear out processes are independent of the external environment and in Model 2, the shocks arrival rate, the shock magnitudes and the wear out rate are governed by a random environment which evolves as a Markov process. We obtain the system’s availability for both models.  相似文献   
3.
Russian Journal of Applied Chemistry - Process of single-stage hydrogenation of phenol to cyclohexanone with industrial (domestic and imported) palladium catalysts, and also with nanocatalysts...  相似文献   
4.
Effective values of reaction order with respect to ligand P, transfer coefficient α, and exchange current i 0 at constant silver surface coverages θ by sulfide ions are measured. The employed solutions contained from 0.4 to 0.05 M thiocarbamide, 0.5 M HClO4, 10?4 M AgNO3, and from 10?5 to 10?4 M Na2S. It is shown that the exchange current grows approximately linearly from 10?5 to 1.5 × 10?4 A/cm2 at θ increase in the range from zero to 0.8, while α and P values grow negligibly in the ranges of 0.4–0.45 and 0.9–1.1, accordingly. The obtained results are compared with the data of similar studies of the gold behavior in acidic thiocarbamide solutions. The possible reasons for the different effects of sulfide ion chemisorption on the anodic dissolution of gold and silver in the studied solutions are discussed.  相似文献   