排序方式: 共有35条查询结果,搜索用时 15 毫秒
1.
A method for the selective detection and determination of hydrogen sulfide in the atmosphere is presented. This method utilizes the reversible adsorption of H2S on a piezoelectric quartz crystal coated with an acetone extract of soots resulting from the burning of organochlorine compounds. The extract of a soot prepared from chlorobenzoic acid provided the best substrate. The method is useful in the concentration range 1–60 ppm. 相似文献
2.
Karmarkar S Koberda M Momani J Kotecki D Garber R 《Journal of chromatography. A》2004,1039(1-2):147-153
In this paper we describe the development and validation of a solid-phase extraction procedure, followed by ion-exclusion chromatographic determination of citrate and acetate in medical fluids. The medical fluids contained trace levels of non-polar compounds, which were not of interest for the purposes of assay requirements, but due to their strong affinity towards the ion-exclusion chromatography column necessitated a 180-min long runtime to elute. The developed SPE procedure, based on trapping the hydrophobic compounds, on a reversed-phase material, while allowing analytes of interest elute off unretained, shortened the runtime to 35 min. The procedure is simple since it has only two steps, conditioning of the SPE cartridge with acetonitrile and treating the sample. The SPE procedure followed by ion-exclusion chromatographic determination was successfully validated per the International Conference on Harmonization (ICH) guidelines in terms of specificity, accuracy as recovery versus untreated sample, precision, range, linearity of response, ruggedness, stability of treated samples, and robustness. The validation data showed that the method is specific, accurate, precise, rugged, and robust. The validated method has been routinely used in the manufacturing environment. 相似文献
3.
V. K. Agrawal S. Karmarkar P. V. Khadikar 《SAR and QSAR in environmental research》2013,24(6):529-545
Abstract The binding of a series of PAT analogues (rodenticides) to the [3H]-mepyramine-labelled H1 receptor in rat and guinea pig brain was investigated topologically using negentropy (N), molecular redundancy (MRI), first-order molecular connectivity (1X v ), Wiener (W), and Szeged (Sz) indices. Multiple regression analyses showed that MRI provided excellent results upon introduction of indicator parameters. Predictive ability of the proposed models was discussed using cross-validation parameters. 相似文献
4.
5.
Sneha Karmarkar P. V. Khadikar Vijay K. Agrawal Keshav C. Mathur Manorama Mandloi Shobha Joshi 《Journal of Chemical Sciences》2000,112(1):43-49
Proton-ligand formation constants of salicylhydroxamic acids (SHA) and their nuclear substituted derivatives have been estimated
topologically using the normalized Wiener index, referred to as mean square Wiener index (Wms). Regression analysis of the
data indicates that Wms can be used successfully for estimating and monitoring proton-ligand formation constants. 相似文献
6.
We consider a competitive version of the traditional aggregate production planning model with capacity constraints. In the general case, multiple products are produced by a few competing producers (oligopoly) with limited capacities. Production quantities, prices and consequently profits depend on production and allocation decisions of each producer. In addition, there is competition for the raw material whose supplies are limited, and where prices reflect these limitations. Such situations have recently occurred in several process industry settings including petro-refining, petrochemicals, basic chemicals, cement, fertilizers, pharmaceuticals, rubber, paper, food processing and metals. We use a successive “Bertrand–Cournot” framework to address this problem and to determine optimal production quantities, prices and profits at the producers and at the raw material supplier. Our analysis allows a new way to understand and evaluate the marginal value of additional capacity when there is competition for the market and raw materials. 相似文献
7.
Inneke Van Nieuwenhuyse Nico Vandaele Kumar Rajaram Uday S. Karmarkar 《European Journal of Operational Research》2007
This paper studies the impact of management policies, such as product allocation and campaign sizing, on the required size of the finished goods inventories in a multi-product multi-reactor batch process. Demand, setup and batch processing times for these products are assumed to be stochastic, and the inventory buffer for every product type needs to be such that target customer service levels are met. To perform this analysis, we develop a queueing model that allows us to explicitly estimate service levels as a function of the buffer size, and the allocation/campaign sizing policies. This model can be used to evaluate the service level given an existing buffer configuration, as well as to determine the buffer sizes required across products to meet a pre-specified service level. It also allows us to formulate a number of insights into how product allocation decisions and campaign planning policies affect buffer sizing decisions in symmetric production systems. 相似文献
8.
Karmarkar S Garber R Genchanok Y George S Yang X Hammond R 《Journal of chromatographic science》2011,49(6):439-446
In this paper, an application of Quality by Design (QbD) concepts to the development of a stability indicating HPLC method for a complex pain management drug product containing drug substance, two preservatives, and their degradants is described. The QbD approach consisted of (i) developing a full understanding of the intended purpose, (ii) developing predictive solutions, (iii) designing a meaningful system suitability solution that helps to identify failure modes, and (iv) following design of experiments (DOE) approach. The starting method lacked any resolution among drug degradant and preservative oxidative degradant peaks, and peaks for preservative and another drug degradant. The method optimization was accomplished using Fusion AE? software (S-Matrix Corporation, Eureka, CA) that follows a DOE approach. Column temperature (50 ± 5°C), mobile phase buffer pH (2.9 ± 0.2), initial % acetonitrile (ACN, 2 ± 1%), and initial hold time (2.5, 5, or 10 min) of the HPLC method were simultaneously studied to optimize separation of the unresolved peaks. The optimized HPLC conditions (column temperature of 50°C, buffer pH of 3.1, 3% initial ACN with 2.5 min initial hold) resulted in fully resolved peaks in the two critical pairs. The QbD based method development helped in generating a design space and operating space with knowledge of all method performance characteristics and limitations and successful method robustness within the operating space. 相似文献
9.
10.
Shreekant V. Karmarkar 《Journal of chromatography. A》1999,850(1-2):303-309
To prevent nutrient enrichment and, hence the undesirable ecological impacts, the nutrients monitored in wastewater samples include two anionic species, i.e., nitrate and orthophosphate, and a cationic species, ammonium. Ion chromatography (IC) is one of the popularly used techniques for determinations of nitrate and phosphate in these samples, whereas determination of ammonium in wastewater samples is typically done using manual or automated wet chemistry, e.g., flow injection analysis (FIA). We have developed a sequential IC–FIA method, using Lachat’s QC8000 IC system, which allows determinations of nitrate, phosphate and ammonia in a single injection. In this system, a QuikChem Small Suppressor cartridge is regenerated in between the samples. A sample is injected while leaving the suppressor off-line. Ammonium, a cation, elutes in the void volume of an anion-exchange column. The unsuppressed column effluent, exiting the conductivity flow cell, up to this point is used for FIA determination of ammonia. When ammonia exits the conductivity flow cell, a fully regenerated suppressor is brought in-line for conductometric detection of the anions. Analog data are simultaneously acquired from colorimetric and conductometric detectors, for the cationic and anionic nutrients, respectively. The method is accurate with spike recoveries in wastewater samples ranging from 91% for nitrate to 114% for chloride. It is precise with RSD values, for replicate analyses (n=7) of a mid-range standard, ranging from 0.4% for phosphate to 1% for nitrate. 相似文献