排序方式: 共有125条查询结果,搜索用时 15 毫秒
1.
2.
Anees A. Al-Hamzawi M. S. Jaafar Nada F. Tawfiq 《Journal of Radioanalytical and Nuclear Chemistry》2014,299(3):1267-1272
The simple and effective technique of fission track etch has been applied to determine trace concentration of uranium in human blood samples taken from two groups of male and female participants: leukemia patients and healthy subjects group. The blood samples of leukemia patients and healthy subjects were collected from three key southern governorates namely, Basrah, Muthanna and Dhi-Qar. These governorates were the centers of intensive military activities during the 1991 and 2003 Gulf wars, and the discarded weapons are still lying around in these regions. CR-39 track detector was used for registration of induced fission tracks. The results show that the highest recorded uranium concentration in the blood samples of leukemia patients was 4.71 ppb (female, 45 years old, from Basrah) and the minimum concentration was 1.91 ppb (male, 3 years old, from Muthanna). For healthy group, the maximum uranium concentration was 2.15 ppb (female, 55 years old, from Basrah) and the minimum concentration was 0.86 ppb (male, 5 years old, from Dhi-Qar). It has been found that the uranium concentrations in human blood samples of leukemia patients are higher than those of the healthy group. These uranium concentrations in the leukemia patients group were significantly different (P < 0.001) from those in the healthy group. 相似文献
3.
4.
Alawainati F. A. Manaa H. Henari F. Z. Biyiklioglu Z. Arslan T. Jaafar A. 《Journal of Applied Spectroscopy》2021,88(5):951-957
Journal of Applied Spectroscopy - Detailed measurements of nonlinear optical properties and optical limiting for four phthalocyanine (Pc) derivatives (PcCo, PcCu, PcMn, and PcSi) are reported. The... 相似文献
5.
Storage area networks (SANs) are an essential part of enterprise computing today. There is no comprehensive business continuity plan without SANs in the picture. This paper proposes and evaluates network survivability of optical paths in wavelength division multiplexing (WDM) based storage area networks in a metro ring network. The paper begins with a background on network survivability in metro WDM ring network. Subsequently, the network and node architectures along with their medium access control (MAC) protocols are described. In this work, one link failure (a single cable cut) in metro WDM based SANs in a ring network architecture is considered. Performance evaluation for network survivability in metro WDM SAN is carried out by means of discrete-event computer simulation. Network throughput and packet delay are investigated. The network performance is evaluated for asymmetric (unbalanced) traffic scenarios under Poisson and self-similar traffic. 相似文献
6.
Martínez-Martín D Jaafar M Pérez R Gómez-Herrero J Asenjo A 《Physical review letters》2010,105(25):257203
In this work we investigate possible ferromagnetic order on the graphite surface by using magnetic force microscopy (MFM). Our data show that the tip-sample interaction along the steps is independent of an external magnetic field. Moreover, by combining kelvin probe force microscopy and MFM, we are able to separate the electrostatic and magnetic interactions along the steps obtaining an upper bound for the magnetic force gradient of 16 μN/m. Our experiments suggest the absence of ferromagnetic signal in graphite at room temperature. 相似文献
7.
P. L. Teh M. Jaafar H. M. Akil K. N. Seetharamu A. N. R. Wagiman K. S. Beh 《先进技术聚合物》2008,19(4):308-315
Epoxy composites containing particulate fillers‐fused silica, glass powder, and mineral silica were investigated to be used as substrate materials in electronic packaging application. The content of fillers were varied between 0 and 40 vol%. The effects of the fillers on the thermal properties—thermal stability, thermal expansion and dynamic mechanical properties of the epoxy composites were studied, and it was found that fused silica, glass powder, and mineral silica increase the thermal stability and dynamic thermal mechanical properties and reduce the coefficient of thermal expansion (CTE). The lowest CTE value was observed at a fused silica content of 40 vol% for the epoxy composites, which was traced to the effect of its nature of low intrinsic CTE value of the fillers. The mechanical properties of the epoxy composites were determined in both flexural and single‐edge notch (SEN‐T) fracture toughness properties. Highest flexural strength, stiffness, and toughness values were observed at fillers content of 40 vol% for all the filled epoxy composites. Scanning electron microscopy (SEM) micrograph showed poor filler–matrix interaction in glass powder filled epoxy composites at 40 vol%. Copyright © 2007 John Wiley & Sons, Ltd. 相似文献
8.
Identification,control strategies,and analytical approaches for the determination of potential genotoxic impurities in pharmaceuticals: A comprehensive review 下载免费PDF全文
Ambavaram Vijaya Bhaskar Reddy Jafariah Jaafar Khalid Umar Zaiton Abdul Majid Azmi Bin Aris Juhaizah Talib Gajulapalle Madhavi 《Journal of separation science》2015,38(5):764-779
Potential genotoxic impurities in pharmaceuticals at trace levels are of increasing concern to both pharmaceutical industries and regulatory agencies due to their possibility for human carcinogenesis. Molecular functional groups that render starting materials and synthetic intermediates as reactive building blocks for small molecules may also be responsible for their genotoxicity. Determination of these genotoxic impurities at trace levels requires highly sensitive and selective analytical methodologies, which poses tremendous challenges on analytical communities in pharmaceutical research and development. Experimental guidance for the analytical determination of some important classes of genotoxic impurities is still unavailable in the literature. Therefore, the present review explores the structural alerts of commonly encountered potential genotoxic impurities, draft guidance of various regulatory authorities in order to control the level of impurities in drug substances and to assess their toxicity. This review also describes the analytical considerations for the determination of potential genotoxic impurities at trace levels and finally few case studies are also discussed for the determination of some important classes of potential genotoxic impurities. It is the authors’ intention to provide a complete strategy that helps analytical scientists for the analysis of such potential genotoxic impurities in pharmaceuticals. 相似文献
9.
Awatef Ayadi Amani Jaafar Adeline Fix-Tailler Ghassan Ibrahim Gérald Larcher Abdelkrim El-Ghayoury 《Tetrahedron》2017,73(25):3554-3563
The synthesis of two tetrathiafulvalene-appended pyridinehydrazone pyrimidine ligands, namely (Z)-4-(2-((5-([2,2′-bi(1,3-dithiolylidene)]-4-yl)pyridin-2-yl)methylene) hydrazinyl)-6-chloropyrimidine L1 and (Z)-4-(2-((6-([2,2′-bi(1,3-dithiolylidene)]-4-yl)pyridin-2-yl)methylene) hydrazinyl)-6-chloropyrimidine L2 is described. Ligand L1 was reacted with cobalt(II) to yield a cationic metal complex [Co(L1)2] while ligand L2 was reacted with zinc(II) to afford a neutral metal complex [ZnL2Cl2]. The crystal structure analysis of [Co(L1)2] indicate that Co(II) ion is coordinated by six nitrogen atoms from two perpendicular ligands while in [ZnL2Cl2], Zn(II) is coordinated by two chlorine atoms and three nitrogen atoms. The electrochemical behavior indicate that ligands L1 and L2 and the zinc(II) complex are suitable fort the preparation of crystalline radical cation salts. Finally the determination of MIC80 values against C. albicans, C. glabrata, C. parapsilosis, C. krusei and E. dermatitidis revealed that the cobalt(II) metal complex [Co(L1)2] is active against all the studied fungi. 相似文献
10.
A dual mode multi-section gain-coupled distributed feedback laser with tunable mode spacing is subharmonically injection locked at 0.315 THz. The injected signal consists of an optical comb with harmonics 35 GHz apart and a bandwidth of approximately 1.9 THz. The optical comb is a result of strong four-wave mixing in a highly-nonlinear dispersion-shifted fiber. In order to observe locking of the multi-section laser, the output is optically downconverted to RF frequencies using the same optical comb. The locked multi-section DFB laser is a coherent and tunable optical source suitable for continuous-wave terahertz generation systems. 相似文献