首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   34篇
  免费   0篇
化学   23篇
数学   2篇
物理学   9篇
  2022年   1篇
  2020年   1篇
  2019年   1篇
  2018年   2篇
  2017年   2篇
  2016年   2篇
  2015年   1篇
  2012年   1篇
  2011年   1篇
  2010年   2篇
  2009年   2篇
  2008年   2篇
  2006年   1篇
  2004年   2篇
  2002年   3篇
  2001年   1篇
  2000年   2篇
  1999年   1篇
  1998年   2篇
  1993年   1篇
  1991年   2篇
  1989年   1篇
排序方式: 共有34条查询结果,搜索用时 810 毫秒
1.
2.
3.
Ventilator-associated pneumonia (VAP) is an infection that arises after endotracheal intubation affecting patients under intensive care. The presence of the endotracheal tube (ETT) is a risk factor since it is colonized by multispecies biofilm. Antimicrobial photodynamic therapy (aPDT) could be a strategy to decontaminate ETTs. We verify if methylene blue (MB) associated with external illumination of the ETT could be an alternative to destroy biofilm. We performed an in vitro and ex vivo study. In vitro study was performed with P. aeruginosa biofilm grew over ETT for 7 days. After treatment, the surviving cells were cultured for 3 days and the biofilm was analyzed by crystal violet absorbance. Ex vivo study employed ETT obtained from extubated patients. aPDT was performed with MB (100 µm ) and red LED (λ = 640±20 nm). We quantified the biofilm thickness and used scanning electron microscopy and fluorescence technique to verify morphological and functional changes after aPDT. Our results showed that bacteria remain susceptible to aPDT after sequential treatments. We also attested that aPDT can reduce biofilm thickness, disrupt biofilm attachment from ETT surface and kill microbial cells. These data suggest that aPDT should be investigated to decrease VAP incidence via ETT decontamination.  相似文献   
4.
This work presents a comparative study of calibration transfer among three near infrared spectrometers for determination of naphthenes and RON (Research Octane Number) in gasoline. Seven transfer methods are compared: direct standardization (DS), piecewise direct standardization (PDS), orthogonal signal correction (OSC), reverse standardization (RS), piecewise reverse standardization (PRS), slope and bias correction (SBC) and model updating (MU). Two pre-treatment procedures, namely standard normal variate (SNV) and multiplicative scatter correction (MSC), are also investigated. The choice of an appropriate number of transfer samples for each technique, as well as the effect of window size in PDS/PRS and OSC components, are discussed. A broad set of gasoline samples representative of the Northeastern states of Brazil is employed in the investigation. The results show that the use of calibration transfer yields prediction errors comparable to those obtained with complete recalibration of the secondary instrument. Overall, the results point to RS as the best method for the analytical problem under consideration. When storage and/or physical transportation of transfer samples are impractical, MU is more appropriate. The comprehensive investigation carried out in the present work will be of value for practitioners involved in networks of fuel monitoring.  相似文献   
5.
A flow-batch system allowing in-line individual sample matrix matching is proposed for analysis of sample lots with high variability in acidity. The feasibility of the approach is demonstrated in the spectrophotometric determination of total nitrogen in Kjeldahl digests, using a column with a slightly soluble reagent (AgCl). The solutions are sequentially injected by means of an 8-port selecting valve and processed in a mixing chamber that is also used as a monitoring unit. The system yields reproducible results (r.s.d. usually < 2.5%) and the sampling rate is 14 samples/h. The analytical curve is linear within 1.00 and 6.00% N (dry basis), and the regression coefficient is > 0.999 (n = 6). Results are in agreement with certified values of standard reference materials and with results obtained by conductometry.  相似文献   
6.
A flow-batch system allowing in-line individual sample matrix matching is proposed for analysis of sample lots with high variability in acidity. The feasibility of the approach is demonstrated in the spectrophotometric determination of total nitrogen in Kjeldahl digests, using a column with a slightly soluble reagent (AgCl). The solutions are sequentially injected by means of an 8-port selecting valve and processed in a mixing chamber that is also used as a monitoring unit. The system yields reproducible results (r.s.d. usually < 2.5%) and the sampling rate is 14 samples/h. The analytical curve is linear within 1.00 and 6.00% N (dry basis), and the regression coefficient is > 0.999 (n = 6). Results are in agreement with certified values of standard reference materials and with results obtained by conductometry. Received: 5 April 2000 / Revised: 6 June 2000 / Accepted: 13 June 2000  相似文献   
7.
PK Srivastava  DK Rai  SB Rai 《Pramana》2001,56(6):823-830
Overtone spectrum of o, m and p-nitrobenzaldehydes and p-chlorobenzaldehyde has been studied in 2000–12000 cm−1 region. Vibrational frequencies and anharmonicity constants for aryl as well as alkyl CH stretch vibrations have been determined. We have also determined the internuclear distances for the aryl CH bond in the different molecules. The small variation observed in these distances is an indication of the substitution effect. It is observed that in the case of p-disubstituted benzens, the shift in aryl CH bond is proportional to sum of the Hammet σ of the substituents. However in the case of o-disubstituted benzenes it is only 80% of the para-substituted shift.  相似文献   
8.
Isomorphously substituted (MeDM) and impregnated metal-containing MCM-41 (MeOx/IM) catalysts, in which Me = Co, Cu, Cr, Fe or Ni, have been prepared. Structural and textural characterizations of the catalysts were performed by means of X-ray diffraction (XRD), chemical analysis, Raman spectroscopy, electron paramagnetic resonance (EPR), N2 adsorption isotherms and temperature programmed reduction (TPR). Cu2+, Co2+, and Cr4+/Cr3+ species were found over the catalysts as cations incorporated in the MCM-41 structure (MeDM) or highly dispersed oxides on the surface (MeOx/IM). The MeDM catalysts exhibited a good performance in the dehydrogenation of ethylbenzene with CO2. However, MeOx/IM catalysts had a low performance in styrene production (activity less than 15 × 10?3 mmol h?1 and selectivity for styrene less than 80%) due to the high reducibility of the metals species. However, Ni2+ or Fe3+ coordinated with the MCM-41 framework, as well as NiOx and Fe2O3 extra-framework species, is continuously oxidized by the CO2 to maintain the active sites for dehydrogenating ethylbenzene. Deactivation studies on the FeDM sample showed that Fe3+ species produced active sp2 carbon compounds, which are removed by CO2; the referred sample is catalytically selective for styrene and stable over 24 h of reaction. In contrast, highly active Ni2+ and Ni0 species produced a large amount of polyaromatic carbonaceous deposits from styrene, as identified by TPO, TG and Raman spectroscopy. An acid–base mechanism is proposed to operate to adsorb ethylbenzene and abstract the β-hydrogen. CO2 plays a role in furnishing the lattice oxygen to maintain the Fe3+ active sites in the dehydrogenation of ethylbenzene to form styrene.  相似文献   
9.
10.
Epidemiological studies have demonstrated an association between the risk of cardiovascular events and increasing C-reactive protein (CRP) concentration. This paper reports the development of an immunosensor for the assessment of the cardiovascular process using anti-C-reactive protein antibody immobilized onto a gold-printed screen electrode. Positive and negative human sera were successfully evaluated using electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV), and atomic force microscopy (AFM). EIS results show that, after the incubation with positive serum for myocardial infarction, the resistance increased about two times in relation to the negative serum. A linear range from 6.25 to 50 μg mL?1 and detection limit of 0.78 μg mL?1 using DPV were obtained. The immunosensor developed for the CRP detection using gold electrode revealed efficacy and a potential use for the diagnosis and monitoring of the progression of cardiovascular diseases.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号