首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   9篇
  免费   0篇
化学   9篇
  2013年   2篇
  2007年   2篇
  2006年   1篇
  2004年   2篇
  1996年   1篇
  1988年   1篇
排序方式: 共有9条查询结果,搜索用时 15 毫秒
1
1.
Cadmium concentration in lake sediments is determined by suspending the solid samples in a solution containing 5% (v/v) concentrated nitric acid and 0.1% (v/v) Triton X-100. Three modifiers were tested for the direct determination. The furnace temperature programmes and appropriate amount for each modifier were optimised to get the highest signal and the best separation between the atomic and background signals. The drying stage is performed by programming a 400 °C temperature, a ramp time of 25 s and hold time of 10 s on the power supply of the atomiser. No ashing step is used and platform atomisation is carried out at 2200 °C. W–Rh permanent modifier combined with conventional modifier by delivering 10 μl of 0.50% (w/v) NH4H2PO4 solution was the best chemical modifier for cadmium determination. This modifier also acts as a liquid medium for the slurry, thus simplifying the procedure. Calibration is performed using aqueous standards in the 1–5 μg l−1 range. The optimised method gave a limit of detection of 0.56 ng ml−1, characteristic mass of 10.1±0.8 pg for aqueous standard, 9.6±0.7 pg for slurry samples containing different Cd concentrations and good precision (7.6–5.2%). The method was validated by analysing four certified reference lake sediment materials: LKSD-1, LKSD-2, LKSD-3 and LKSD-4; satisfactory recoveries were obtained (90.0–96.3%) and no statistical differences were observed between the experimental and the certified cadmium concentration. The developed methodology was used to determine cadmium in three ‘real’ sediment samples from lakes in the area of Wielkopolski National Park, Poland.  相似文献   
2.
In order to evaluate the slurry nebulisation method as an alternative method for analysis of sewage sludge, the metal content of sludge samples of different origins was determined. The concentrations of six elements: Cd, Cr, Cu, Ni, Pb, and Zn were determined by introducing the sludge as a slurry into an inductively coupled plasma optical emission spectrometer (ICP-OES). Calibration was performed by using aqueous standard solutions. For comparison, the sewage sludge was also digested by microwave digestion and introduced into the plasma as an aqueous solution. The accuracy of the method was checked by analysing a sewage sludge certified reference material (CRM 007-040 Sewage Sludge). The Student's t-test showed that values obtained using slurry nebulisation were close to the certified values at a 95% confidence level. The values of elements Cd 11.1?±?0.8; Cr 37.7?±?3.3; Cu 563.3?±?38.4; Pb 119.2?±?10.1; Zn 729?±?68.2?mg?kg?1 obtained using this method were comparable with those obtained using the conventional method. The slurry method can, therefore, be successfully applied to the determination of content of each element in sewage sludge with RSD less than 3%, without the need to predissolve them. This could avoid the use of hazardous chemicals, incomplete dissolution and loss of volatile analytes.  相似文献   
3.
Due to their restricted conformational flexibility, cyclic peptides are of great interest in connection with structure-activity relationships, especially the elucidation of bioactive conformations. For linear peptides that do not contain turn structure-inducing amino acid residues, the cyclization reaction may be an inherently improbable or slow process, and side reactions, such as cyclodimerization and epimerization at the C-terminal residue, may dominate. A number of 1-hydroxy-7-azabenzotriazole-based onium salts were examined for cyclization of thymopentin-derived pentapeptides and the results compared with data from more conventional coupling reagents. The azabenzotriazol-derived coupling reagents stood out as being the most effective by far. The cyclizations proceed extremely rapidly, and in contrast to other coupling reagents, C-terminal epimerization was generally less than 10%. C-terminal D-amino acid residues favor the formation of monocyclic pentapeptide rings. A similar effect was observed for cyclization of linear N-methylamino acid-containing peptides, suggesting that reversible amide bond alkylation such as Hmb-modification should be useful in promoting the cyclization of pepitdes devoid of turn-inducing amino acid residues.  相似文献   
4.
Pb, Mg and Ca were simultaneously determined in plant roots by slurry introduction into inductively coupled plasma optical emission spectrometry (SS-ICP-OES). Slurries were prepared in 0.5% or 5% (v/v) HNO3 with 0.5, or 5% (v/v) Triton X-100. Omission of the Triton X-100 improved results. Compared with wet ashing of the root sample followed by ICP-OES, ICP-MS and FAAS, the method offers: comparable results, simplification of sample preparation, less sample contamination, and reduction in the use of dangerous and corrosive reagents. The precisions varied: 1.7% for Mg, 2.8% for Ca and 4.3% for Pb, and were not significantly different (95% confidence level) from those of conventional analysis.   相似文献   
5.
ChemInform is a weekly Abstracting Service, delivering concise information at a glance that was extracted from about 200 leading journals. To access a ChemInform Abstract, please click on HTML or PDF.  相似文献   
6.
The comparative determination of lead in plant samples by two atomic spectrometric techniques is reported. At first, slurry sampling electrothermal atomisation atomic absorption spectrometry (ETAAS) was applied. The results obtained were compared with those found after a wet digestion procedure by flame atomic absorption spectrometry (FAAS) or ETAAS. The accuracy of the studied methods was checked using a certified reference material (CL???1 CRM, Cabbage Leaves). The recovery of lead was 90% for slurry sampling ETAAS, and 86.6% for liquid sampling ETAAS. The advantages of the slurry sampling ETAAS method are the simplicity of sample preparation and very good sensitivity.  相似文献   
7.
A direct and sensitive method for the determination of vanadium concentrations in soil is developed using ultrasonic slurry sampling electrothermal atomic absorption spectrometry (USSSETAAS). The surfactant, KO300G, is used as the stabilizing agent. The precision and accuracy of the method are investigated. The detection limits are 0.6 and 0.7 μg 1−1 for SRM Montana Soil 2711 and SRM Soil — S, respectively. The method is applied to determine the vanadium content in 10 soil samples from the Wielkopolska region.  相似文献   
8.
Refluxing of ethanol-acetic acid solutions of N-aroyl-N-methyl-benzoylacetamides3 causes elimination of acetophenone and generation of N(1)-substituted N(3)-methyl-1H,3H-quinazoline-2,4-diones5. In contrast, at room temperature in acetanhydride3 eliminate water yielding 2-benzoylmethylene-quinazolinones4, which at 60 °C cyclize to pyrrolo[1,2-a] quinazolin-5-ones6. The transformation4 6 may be explained in terms of a normalKnorr reaction. A anomalousKnorr reaction was observed in the case of the more rigid4 d leading to a mixture of diasteromere7 d cis and7 d trans in kinetically controlled reaction. Favoured by intramolecular hydrogen bonding7 d cis converts to the thermodynamically more stable6 d by warming of the ethanolic solution for 3 hours.
  相似文献   
9.
Slurry sampling electrothermal atomic absorption (SS ETAAS) was applied to the development of a sensitive and precise method for selenium determination in infant foods without sample pretreatment. Suspensions prepared in a medium containing 0.1% Triton X-100, 0.5 or 5% v/v concentrated HNO3 were directly introduced into the furnace. The accuracy of the procedure was confirmed by analysis of a standard reference material and comparison with hydride generation atomic absorption spectrometric (HGAAS) procedure. The characteristic mass is 44 pg and detection limit 0.43 μg·l−1.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号