排序方式: 共有57条查询结果,搜索用时 15 毫秒
1.
Jia Tian-Cong Guo Jin-Tao Wang Zhen Zhu Xiao-Shan Zhang Qian-Xin Chen Ping Yao Kun Lv Wen-Ying Liu Guo-Guang 《Journal of Radioanalytical and Nuclear Chemistry》2019,321(3):823-829
Journal of Radioanalytical and Nuclear Chemistry - In the present work the final products of coumarin radiation chemical transformation are investigated by chromatography. During radiolysis of... 相似文献
2.
将磺化聚苯乙炔(SPPA)与多壁碳纳米管(MWCNTs)超声共混制备得到SPPA/MWCNTs复合材料. 用X光电子能谱仪、固体紫外-可见分光光度计、X射线衍射仪、四探针、场发射扫描电镜等对复合材料导电特性及机理进行研究. 结果表明: SPPA/MWCNTs 复合材料中SPPA与MWCNTs发生电荷转移而被掺杂, 并且由于SPPA与MWCNTs间的电荷转移, 彼此间存在一定的相互作用力; 复合材料电阻呈负温度系数效应; SPPA/MWCNTs复合材料电导率发生两次突跃. 可能的导电机理为, 复合材料中SPPA不仅被MWCNTs物理填充, 同时还被MWCNTs掺杂, 复合材料中存在两种导电通路, 一是SPPA与MWCNTs的碳原子发生电荷转移而被掺杂, 彼此之间存在一定的相互作用力, 导致SPPA包裹MWCNTs形成独立导体单元, 这种独立单元相互接触形成导电通路; 二是MWCNTs彼此之间相互接触形成导电通路, 并建立了该导电机理的理论模型. 相似文献
3.
4.
研究了浸提时间、液料比、溶剂酸碱度和浸提温度对提取效果的影响。在单因素试验的基础上对提取咖啡因的工艺条件进行了优化,优化结果显示,浸提温度在咖啡因的提取过程中影响最为显著,其次是提取时间、pH值和液料比,各因素较优的水平为浸提温度80℃,浸提时间90 min,液料比为30∶1,pH=7,并对正交实验数据分别作多元一次和二次回归,得到相应的回归方程。最后以正交实验为基础建立了人工神经网络优化模型,该模型的优化结果为浸提温度100℃,浸提时间115 min,液料比为41∶1,pH=4.5。实验证明,人工神经网络得出的结果优于正交实验,二者结果的差异在于多因素之间的交互作用。 相似文献
5.
Gallium Nitride (GaN) room temperature α particle detectors are fabricated and characterized, whose device structure is Schottky diode. The current-voltage (I- V) measurements reveal that the reverse breakdown voltage of the detectors is more than 200 V owing to the consummate fabrication processes, and that the Schottky barrier and ideal factor of the detectors are 0.64 eV and 1.02, respectively, calculated from the thermionic transmission model. ^241Am α particles pulse height spectra from the GaN detectors biased at -8 V is obviously one Gauss peak located at channel 44 with the full width at half maximum (FWHM) of 15.87 in channel. One of the main reasons for the relatively wider FWHM is that the air between the detectors and isotope could widen the spectrum. 相似文献
6.
An anatomically accurate eye model with a shell-structure lens 总被引:1,自引:0,他引:1
A human eye model based on anatomically accurate eye model previously proposed by Liou, has been transformed into a new eye model, in which laminated structure of the lens is considered. The crystalline lens is presented in the form of hundreds of shells with rotational symmetry, and with constant index within each shell. The refractive index increases from the cortical shell to the inner one, according to the equation proposed by Smith G. et al. The anterior surface of the lens is prolate, whereas the posterior surface of the lens is oblate which is consistent with the anatomical data. A ray tracing procedure has been applied to study the refractive structure of the eye. The optical characters of the model have been studied. The reason that the wings occur on the spherical aberration curve has been given. And we found that the lens with gradient refractive index and lens with shell structure can give same longitudinal spherical aberration results. 相似文献
7.
The excitation energies and term energies of the excited states 1s2ns (n=3,4,5) and 1s2nf (n=4,5) of lithium-like systems of Z=11-20 下载免费PDF全文
In this paper, the full-core plus correlation (FCPC) and the Ritz method is extended to calculate the non-relativistic energies of 1s^2ns (n=3,4,5) and 1s^2nf (n=4,5) states and the wavefunctions of the lithium-like systems from Z=11-20. The mass-polarization and the relativistic correction including the kinetic-energy correction, the Darwin term, the electron-electron contact term, and the orbit-orbit interaction are evaluated perturbatively as the first-order correction. The contribution from quantum electrodynamic is also included by using the effective nuclear charge formula. The excited energies, the term-energy and fine structure, are given and compared with the other theoretical calculation and experimental results. It is shown that the correlative wave in the FCPC method embodies well the strong correlation between the 1s^2 core and the valence electron. 相似文献
8.
9.
10.
Correlation between Post-LASIK Starburst Symptom and Ocular Wavefront Aberrations 总被引:2,自引:0,他引:2 下载免费PDF全文
Monochromatic aberrations in post laser in-situ keratomileusis (LASIK) eyes are measured. The data are categorized into reference group and starburst group according to the visual symptoms. Statistic analysis has been made to find the correlation between the ocular wavefront aberrations and the starburst symptom. The rms aberrations of the 3rd and 4th orders for the starburst group are significantly larger than those for the reference group. The starburst symptom shows a strong correlation with vertical coma, total coma, spherical aberrations. For 3-mm pupil size and 5.8-mm pupil size, the modulation transfer function (MTF) of the starburst group are lower than those of the reference group, but their visual acuities are close. MTF and PSF analyses are made for two groups, and the results are consistent with the statistical analysis, which means the difference between the two groups is mainly due to the third- and fourth-order Zernike aberrations. 相似文献