排序方式: 共有10条查询结果,搜索用时 19 毫秒
1
1.
2.
John Gormally 《Trends in analytical chemistry : TRAC》1992,11(10):384-388
Over about the last twenty years, the use of laser techniques has become increasingly common in the field of mass spectrometry. Here, we give a brief overview of the varied applications of lasers in this area. These developments are far from complete and they are expected to continue. However, laser methods have already made valuable contributions to problems of mass analysis and it seems likely that they are here to stay. 相似文献
3.
EP Sheretov VS Gurov MV Dubkov OV Korneeva 《Rapid communications in mass spectrometry : RCM》1999,13(16):1699-1702
In this article we compare the classical monopole mass filter of von Zahn and the monopole mass filter with a hyperbolic V-shaped electrode. The experimental results and those of computer simulation for both mass spectrometers are presented. We show that the replacement of a conventional 90 degrees V-shaped electrode by an electrode with a hyperbolic profile substantially improves the peak shape of any given mass, and increases the mass resolution by a factor of 3-4 and the abundance sensitivity by a factor of 100. The potential of high analytical performance combined with electroforming techniques for electrode manufacture indicate future practical uses of such instruments. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
4.
5.
6.
DC magnetization, neutron depolarization and neutron diffraction (with both polarized and unpolarized neutrons) measurements
have been reported for the Co1.1−x
Zn
x
Ge0.1Fe1.2O1 spinels with x=0.5, 0.6 and 0.7. Neutron depolarization and neutron diffraction measurements confirm the presence of a long range ferrimagnetic
ordering of the local canted spins in these ferrite samples. The observed features of low field magnetization have been explained
under the framework of thermally activated domain wall movement of ferrimagnetic arrangement of local canted spins. An important
role of magnetic anisotropy (due to the presence of Co2+ ions) in establishing the magnetic ordering and domain kinetics in these ferrites has been observed. 相似文献
7.
Lane TJ Fletcher WR Gormally MV Johal MS 《Langmuir : the ACS journal of surfaces and colloids》2008,24(19):10633-10636
The electrostatically driven binding dynamics of a polyelectrolyte multilayer (PEMU) film was investigated in real-time using dual-beam polarization interferometry (DPI) and independently supported by quartz crystal microbalance with dissipation monitoring (QCM-D) studies. Multilayer assemblies of the polyanions poly[1-[4[(3-carboxy-4-hydroxyphenylazo)benzenesulfonamido]-1,2-ethanediyl sodium salt] (PAZO) and poly(styrene sulfonate) (PSS) were respectively constructed with the polycation poly(ethylenimine) (PEI) on anionic functionalized substrates using the layer-by-layer electrostatic self-assembly method. DPI measurements indicate that polyelectrolyte adsorption occurs in three distinct stages. In the first stage, for approximately 5 s, coil-like segments of polyanion partially tether to the surface of the oppositely charged PEI. In the second stage, these coils unfurl over a period of approximately 10 s to cover the surface resulting in an increase in average density of the film. During the final adsorption step, the surface-bound polyelectrolyte diffuses into the multilayer assembly, exposing the surface to further deposition. This last step occurs over a much longer time period and results in a highly interpenetrated film containing a charge-overcompensated region at the film surface. 相似文献
8.
MV Muftakhov YV Vasil'ev VA Mazunov 《Rapid communications in mass spectrometry : RCM》1999,13(12):1104-1108
Appearance energies of [M-H](-) ions from carbonyl compounds R-CO-R' (R,R' = H, CH(3), NH(2), OH) have been measured by means of negative ion mass spectrometry in resonant electron capture mode. Values of electron affinity of the corresponding radicals, CH(2)&dbond;C(X)O, NH&dbond;C(X)O and O&dbond;C(X)O, have been determined. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
9.
10.
A method of determining the free dye concentration in a dye/polyelectrolyte solution is described. The method utilizes the tendency of cationic dyes to adsorb to a cellulose dialysis membrane, and the nature of the membrane binding is studied by spectrophotometric methods. The binding of the cationic dye toluidine blue to the polyanion sodium carboxymethylcellulose in solution is used as an example. The proposed technique gives reliable estimates of free dye concentration over a wide range of polyanion and dye concentrations, both in the presence and absence of added simple electrolyte. The method possesses inherent advantages over estimates of free dye concentration obtained by absorption spectrophotometry and is more versatile than fluorimetry. 相似文献
1