首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   1篇
化学   12篇
数学   2篇
物理学   2篇
  2021年   1篇
  2019年   1篇
  2017年   1篇
  2014年   1篇
  2013年   1篇
  2012年   1篇
  2011年   2篇
  2010年   2篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2002年   2篇
  1996年   1篇
排序方式: 共有16条查询结果,搜索用时 62 毫秒
1.
In this study, we describe for the first time the application of an internal standard method to compensate for random errors associated with the injection procedure in batch injection analysis (BIA) systems with multiple pulse amperometric detection. A sequence of potential pulses was selected in such a way that the internal standard (IS) compound was detected individually at one potential pulse and both the IS and analyte, were detected at another potential pulse. The current ratio (IIS+analyte/IIS) was used in the construction of the calibration curve and then to compensate for random errors. The use of disposable syringes or manual pipettes in BIA systems increases the robustness of the method and dispenses with skilled operators.  相似文献   
2.
Dimenhydrinate (DIM) is a salt composed by the combination of two active pharmaceutical ingredients: diphenhydramine (DIP) and 8‐chlorotheophylline (CTP). In this work, the use of batch injection analysis with multiple pulse amperometric detection (BIA‐MPA) was proposed for the first time for fast stoichiometric determination of DIM. DIP (cation) and CTP (anion) were determined simultaneously in pharmaceutical samples with a simple and fast injection procedure (70 injections h?1). Additional strategies were also proposed for rapid screening of samples containing the DIM salt. By a simple injection of a sample into the BIA system (without using of calibration curve), reliable information about stoichiometry of the DIM salt (1 : 1; DIP:CTP) and presence or absence of interfering species (electroactive) can be achieved.  相似文献   
3.
In this work, we describe for the first time the use of the internal standard method in flow injection analysis (FIA) with amperometric detection. The method is based on the application of sequential potential pulses to the working electrode in an electrochemical flow cell. The sequence of potential pulses is selected in such a way that the analyte and internal standard compound are detected and monitored individually and independently at the same working electrode. This approach compensates for random errors associated with variations of flow rate, injection volume, ionic strength difference between standards and samples, and accidental insertion or formation of air bubbles in the carrier stream. In addition, this method can overcome the major drawback of amperometric detection using solid electrodes, which is gradual electrode passivation. To illustrate the potential of this method, the flow-injection amperometric detection of uric acid using [Fe(CN)6]3? as an internal standard (IS) is presented as an example.  相似文献   
4.
The present work reports a simple and quick strategy for simultaneous determination of paracetamol (PC) and ascorbic acid (AA) in pharmaceutical formulations using flow injection method with multiple pulse amperometric detection. The method allows the resolution of the mixture without chemical pretreatment of the sample or electrode modification or the use of chemometric techniques for data analysis. The compounds are detected by applying four sequential pulses (waveform) in function of time to a three‐electrode amperometric system that uses a wall‐jet cell with gold as working electrode. AA is direct detected at +0.40 V and PC is indirectly detected at 0.0 V by the reduction (desorption) of the oxidation product (N‐acetyl‐p‐benzoquinoneimine) electrochemically generated at +0.65 V. The fourth potential pulse (?0.05 V) is applied for the complete regeneration (cleaning) of the gold electrode surface. The linear response range was optimized between 5 and 24 mg L?1 for AA and 50 and 240 mg L?1 for PC. The difference between the two responses ranges (10‐fold) present correlation with the concentration of these compounds in two different pharmaceutical formulations available in the Brazilian market. The analytical frequency was calculated in 60 injections per hour. The use of the proposed methodology for PC quantification in the presence of higher AA concentrations was also carried out. Using the standard addition method, it was possible to detect PC in trace levels (LD=0.2 mg L?1) in the presence of 880‐fold more of AA (176 mg L?1).  相似文献   
5.
We consider a certain type of second-order neutral delay differential systems and we establish two results concerning the oscillation of solutions after the system undergoes controlled abrupt perturbations (called impulses). As a matter of fact, some particular non-impulsive cases of the system are oscillatory already. Thus, we are interested in finding adequate impulse controls under which our system remains oscillatory.  相似文献   
6.
A systematic approach is proposed to evaluate microwave-assisted digestion in a single reaction chamber for the simultaneous determination of elements in the mineral fertilizer and raw material by inductively coupled plasma optical emission spectrometry. A reference material was digested using 12 acid mixtures containing nitric, hydrochloric, orthophosphoric, hydrofluoric or boric acid. Principal components analysis was applied for data treatment. Three digestion procedures based on diluted acids exhibited the most accurate results, with relative errors for reference values ranging from ?15% to +?9%. Limits of quantification were in the range of 0.2?mg cadmium kg?1 up to 1000?mg aluminum kg?1.  相似文献   
7.
Oxygen availability is the most important environmental parameter in the production of xylitol by yeasts, directly affecting yields and volumetric productivity. This work evaluated the cell behavior in fermentations carried out with different dissolved oxygen concentrations (0.5–30.0% of saturation), as well as a limited oxygen restriction (0% of saturation), at several oxygen volumetric transfer coefficients (12 ≤ k L a ≤ 70 h−1). These experiments allowed us to establish the specific oxygen uptake rate limits to ensure high yields and volumetric productivity. When oxygen availability was limited, the specific oxygen uptake rate values were between 12 and 26 mg of O2/of g cell·h, resulting in a yield of 0.71 g of xylitol/xylose consumed, and 0.85 g/[L·h] for the volumetric productivity. According to the results, the effective control of the specific oxygen uptake rate makes it possible to establish complete control over this fermentative process, for both cell growth and xylitol production.  相似文献   
8.
This paper presents a method for fast and simultaneous determination of diclofenac (DCF) and its common counter‐ions (potassium, sodium, and diethylammonium) using CE with capacitively coupled contactless conductivity detection (CE‐C4D). On the basis of a single electropherogram (about 50 s), the proposed method allows the determination of the stoichiometry, absolute quantification and evaluation of the degradation degree of the active pharmaceutical ingredient (DCF). A linear working range from 100 to 500 μmol/L was obtained for all analytes in an equimolar TRIS/TAPS (10 mmol/L) solution as the background electrolyte as well as adequate LOD (7, 6, 7, and 10 μmol/L for K+, Na+, diethylammonium, and DCF, respectively). The proposed method was applied to the analysis of pharmaceutical formulations (tablets and spray form) with similar results to those achieved by HPLC (DCF) or flame photometry (K and Na) at a 95% confidence level.  相似文献   
9.
The coupling of the Einstein-Hilbert Lagrangian with a conformal field in an arbitrary even dimension leads, after reduction to four dimensions, to the ordinary gravity coupled non-trivially to two scalar fields. The vacuum solutions display an initial singularity, but with an infinite proper distance between any two points of the space-time. There is an initial contraction phase followed by an expansion phase. This is a kind of anti-Big Bang scenario. The coupling to a radiative fluid preserves this feature; however, the temperature of the radiative fluid is initially zero, increasing afterwards: its maximum value is related to the moment where the horizon crosses the radius of the Universe. The entropy in the three-dimensional space is inversely proportional to the volume of the internal space, and it can be very high today. We perform also a perturbative study of this model during the contraction phase. There is no explosive growth of the scalar perturbations.  相似文献   
10.
In this work, we report a simple and novel strategy for simultaneous analysis using flow injection analysis with multiple pulse amperometric (FIA‐MPA) detection. The proposed strategy was successfully used for simultaneous determination of paracetamol and caffeine (model analytes) in pharmaceutical formulations. A sequence of potential pulses (waveform) was selected in such a way that PA is selectively oxidized at E1 (+1.20 V/50 ms) and both compounds (PA+CA) are simultaneously oxidized at E2 (+1.55 V/50 ms); hence, current subtraction (using a correction factor) can be used for the selective determination of CA. The proposed FIA method is simple, cheap, fast (140 injections h?1), and present selectivity for the determination of both compounds in pharmaceutical samples, with results similar to those obtained by HPLC at a 95 % confidence level.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号