1.
This paper describes a micromachined piezoelectric sensor, integrated into a cavity at the tip of a biopsy needle, and preliminary experiments to determine if such a device can be used for real-time tissue differentiation, which is needed for needle positioning guidance during fine needle aspiration (FNA) biopsy. The sensor is fabricated from bulk lead zirconate titanate (PZT), using a customized process in which micro electro-discharge machining is used to form a steel tool that is subsequently used for batch-mode ultrasonic micromachining of bulk PZT ceramic. The resulting sensor is 50 microm thick and 200 microm in diameter. It is placed in the biopsy needle cavity, against a steel diaphragm which is 300 microm diameter and has an average thickness of 23 microm. Devices were tested in materials that mimic the ultrasound characteristics of human tissue, used in the training of physicians, and with porcine fat and muscle tissue. In both schemes, the magnitude and frequency of an electrical impedance resonance peak showed tissue-specific characteristics as the needle was inserted. For example, in the porcine tissue, the impedance peak frequency changed approximately 13 MHz from the initial 163 MHz, and the magnitude changed approximately 1600 Omega from the initial 2100 Omega, as the needle moved from fat to muscle. Samples including oils and saline solution were tested for calibration, and an empirical tissue contrast model shows an approximately proportional relationship between measured frequency shift and sample acoustic impedance. These results suggest that the device can complement existing methods for guidance during biopsies.  相似文献   
2.
Liu J  Gupta NK  Wise KD  Gianchandani YB  Fan X 《Lab on a chip》2011,11(20):3487-3492
This paper reports the investigation of a micro-gas chromatography (μGC) system that utilizes an array of miniaturized motionless Knudsen pumps (KPs) as well as microfabricated separation columns and optical detectors. A prototype system was built to achieve a flow rate of 1 mL min(-1) and 0.26 mL min(-1) for helium and dry air, respectively, when they were used as carrier gas. This system was then employed to evaluate GC performance compromises and demonstrate the ability to separate and detect gas mixtures containing analytes of different volatilities and polarities. Furthermore, the use of pressure programming of the KP array was demonstrated to significantly shorten the analysis time while maintaining a high detection resolution. Using this method, we obtained a high resolution detection of 5 alkanes of different volatilities within 5 min. Finally, we successfully detected gas mixtures of various polarities using a tandem-column μGC configuration by installing two on-column optical detectors to obtain complementary chromatograms.  相似文献   
3.
This paper describes the use of microdischarges as transducing elements in sensors and detectors. Chemical and physical sensing of gases, chemical sensing of liquids, and radiation detection are described. These applications are explored from the perspective of their use in portable microsystems, with emphasis on compactness, power consumption, the ability to operate at or near atmospheric pressure (to reduce pumping challenges), and the ability to operate in an air ambient (to reduce the need for reservoirs of carrier gases). Manufacturing methods and performance results are described for selected examples.
Figure
Side-view photograph of an ultraviolet light source that uses microdischarges  相似文献   
4.
The direct preparation of thermoresponsive monolithic copolymers by photopatterning of a liquid phase consisting of an aqueous solution of N-isopropylacrylamide, N-ethylacrylamide, N,N'-methylenebisacrylamide, and 4,4'-azobis(4-cyanovaleric acid) has been studied and the products used as valves within the channels of microfluidic devices. The volume change associated with the polymer phase transition at its lower critical solution temperature (LCST) leads to the rapid swelling and the deswelling of the 2.5% cross-linked monolithic gel thus enabling the polymer to close or open the channel and to function as a nonmechanically actuated valve. The LCST at which the valve switches was easily adjusted within a range of 35 degrees C-74 degrees C by varying the proportions of the monovinyl monomers in the polymerization mixture. The closed valve holds pressures of up to 18 MPa without noticeable dislocation, structural damage, or leakage. In contrast, following deswelling by raising the temperature above LCST the valve offers no appreciable flow resistance since its large, micrometer-size pores are open. Laser-triggered photobleaching of a fluorescent dye contained in the liquid phase enabled monitoring of flow through the device and determination of the times required to open and close the valve. The valves are characterized by very fast actuation times in a range of 1-4 s depending on the type of device. No changes in performance were observed even after repeated open-close cycling of the valves.  相似文献   
5.
This paper reports a discharge-based optical source for fluorescence of biochemicals in microfluidic systems. Its efficacy is demonstrated using a stacked microchip that integrates a microfluidic wavelength-tunable optical source, a biochemical sample reservoir and optical filters. It is shown to excite fluorescence in l-tryptophan and DNA samples labeled by SYBR green dye. The discharge is struck in ambient air, between a metal anode and a cathode cavity that is filled with an aqueous solution, which is doped with a metal salt selected for its emission characteristics. The characteristic line spectra, which arise from energetic transitions of the metal ions that are sputtered into the glow region of the discharge, are optically filtered and guided to the biochemical sample that resides in a separate on-chip reservoir. For DNA fluorescence, a barium chloride solution is used to emit light at 454 and 493 nm. For tryptophan fluorescence, the cathode contains lead (ii) nitrate solution to provide a 280 nm emission. The resulting fluorescence from the DNA and tryptophan samples is compared to reference data. This technique can also be used to excite other fluorophores by using appropriately doped liquid cathodes having the desired emission characteristics.  相似文献   