首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   43篇
  免费   0篇
化学   42篇
物理学   1篇
  2021年   2篇
  2013年   1篇
  2012年   1篇
  2011年   3篇
  2010年   4篇
  2009年   12篇
  2008年   4篇
  2007年   4篇
  2006年   4篇
  2005年   4篇
  2004年   3篇
  1997年   1篇
排序方式: 共有43条查询结果,搜索用时 15 毫秒
1.
In this paper a solid-phase microextraction–gas chromatography–mass spectrometry (SPME–GC–MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)—venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline—in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL–1 urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.  相似文献   
2.
An in situ derivatization solid-phase microextraction method has been developed for the determination of parabens, triclosan and related chlorophenols in water. Acetylated derivatives are selectively determined using gas chromatography with tandem mass spectrometry. Parameters affecting both derivatization and SPME procedures, such as fiber coating, extraction mode, temperature, volume of derivatizating reagent and ionic strength, are studied and optimized through a multifactorial experimental design. The performance of the method is studied in terms of accuracy, linearity, precision and limits of detection. Quantitative recoveries (≥82%) and satisfactory precision (RSD ≤ 12%) are obtained. Limits of detection at the low picogram per millilitre level are achieved for all target compounds. Linearity is studied in a wide range of concentrations and an analysis of variance with a lack-of-fit test is run to validate the calibration data. Extraction time profiles are also obtained. Finally, the applicability of the proposed method is demonstrated for several real samples including river water, wastewaters and swimming pool water. Since no matrix effects are observed, quantification can readily be carried out by external calibration with ultrapure water standards.  相似文献   
3.
A new method based on solid phase dispersion-pressurized liquid extraction (PLE) followed by gas chromatography-mass spectrometry (GC-MS) has been developed for the determination of 26 suspected fragrance allergens (all the regulated in the EU Cosmetics Directive amenable by GC, as well as pinene and methyleugenol) in cosmetic samples. The effects of the temperature, extraction time and solvent, and dispersing sorbent, affecting the whole proposed procedure, have been evaluated using a multifactor strategy. The optima conditions after the analysis of main and second order effects entailed the extraction at 120°C for 15 min, using hexane/acetone as solvent, and florisil as dispersing sorbent. The method performance has been studied, showing good linearity (R≥0.996) as well as good precision (RSD≤10%). Detection limits (S/N=3) ranged from 0.000001 to 0.0002% (w/w), values far below the established restrictions as regard labelling in the European Cosmetics Regulation. Reliability was demonstrated through the quantitative recoveries of all the studied compounds. The absence of matrix effects allowed quantification of the compounds by calibration with standard solutions. The analysis of 10 samples (several moisturizing and anti-wrinkle creams and lotions, hand creams, and sunscreen and after-sun creams), covering very different matrices, showed the presence of suspected allergens in all the analyzed samples; in fact, half of the samples contained an elevated number of them. Although the ubiquity of these compounds was demonstrated, labelling was in all cases in consonance with the European Cosmetics Regulation.  相似文献   
4.
Matrix solid-phase extraction has been successfully applied for the determination of multi-class preservatives in a wide variety of cosmetic samples including rinse-off and leave-on products. After extraction, derivatization with acetic anhydride, and gas chromatography–mass spectrometry analysis were performed. Optimization studies were done on real non-spiked and spiked leave-on and rinse-off cosmetic samples. The selection of the most suitable extraction conditions was made using statistical tools such as ANOVA, as well as factorial experimental designs. The final optimized conditions were common for both groups of cosmetics and included the dispersion of the sample with Florisil (1:4), and the elution of the MSPD column with 5 mL of hexane/acetone (1:1). After derivatization, the extract was analyzed without any further clean-up or concentration step. Accuracy, precision, linearity and detection limits were evaluated to assess the performance of the proposed method. The recovery studies on leave-on and rinse-off cosmetics gave satisfactory values (>78% for all analytes in all the samples) with an average relative standard deviation value of 4.2%. The quantification limits were well below those set by the international cosmetic regulations, making this multi-component analytical method suitable for routine control. The analysis of a broad range of cosmetics including body milk, moisturizing creams, anti-stretch marks creams, hand creams, deodorant, shampoos, liquid soaps, makeup, sun milk, hand soaps, among others, demonstrated the high use of most of the target preservatives, especially butylated hydroxytoluene, methylparaben, propylparaben, and butylparaben.  相似文献   
5.
The sonochemical degradation of 5 μg l−1 triclosan, a priority micro-pollutant, in various environmental samples (seawater, urban runoff and influent domestic wastewater) as well as in model solutions (pure and saline water) was investigated. Experiments were conducted with a horn-type sonicator operating at 80 kHz frequency and a nominal applied power of 135 W, while solid-phase microextraction coupled with gas chromatography–electron capture detector (SPME/GC–ECD) was employed to monitor triclosan degradation. The latter followed pseudo-first order kinetics with the rate constant being (min−1): 0.2284 for seawater > 0.1051 for 3.5% NaCl in deionised water > 0.0597 for centrifuged urban runoff  0.0523 for untreated urban runoff > 0.0272 for deionised water > 0.0063 for wastewater influent. SPME/GC–ECD and SPME coupled with gas chromatography–mass spectrometry (SPME/GC–MS) were also used to check for the formation of chlorinated and other toxic by-products; at the conditions in question, the presence of such compounds was not confirmed.  相似文献   
6.
Investigation of chemical exposure inside the homes and offices where people spend the majority of their lives has only recently begun. These chemicals are degraded much more slowly than outdoor because they are more protected from sunlight, severe environmental conditions and microbial activity. Hence, indoor dust has been recognized as an important exposure pathway for organic contaminants. Pyrethroids are synthetic insecticides widely used in domestic environment for numerous applications and also in agriculture. Chlorobenzenes are a family of compounds used as intermediates in the production of a wide range of household consumer products. Nitromusks are a kind of synthetic musks used in the production of cleaning agents, detergents, and personal care products. A high-throughput method for the determination of these compounds in indoor dust samples has been developed. Microwave-assisted solvent extraction was used as the extraction technique whereas quantification of compounds was carried out by gas chromatography with micro-electron-capture detection. Several cleanup procedures were tested and finally a non-classical "on batch" procedure was selected, which allows increasing the throughput of the analysis while decreasing sample manipulation. Extraction conditions were optimized using a multifactorial experimental design approach. Quantitative recovery (84-103%) was achieved for all compounds and method precision was satisfactory. Limits of detection ranged from 0.22 ng g(-1) for lindane to 40 ng g(-1) for 1,4-dichlorobenzene. Standard reference material SRM 2585 was analyzed and the obtained values were in good agreement with the reported reference values for organochlorinated compounds and nitromusks. Pyrethroids and polychlorobenzenes have been analyzed for the first time in this reference material and some of them have been found. In addition, real samples collected in houses of north-western Spain have been analyzed by the proposed method and 17 of the 22 target compounds have been detected in the samples.  相似文献   
7.
A method based on solid-phase enrichment followed by headspace (HS)-solid-phase microextraction (SPME) is optimized to determine pyrethroids in air. By active sampling, pyrethroids present in air are retained in 25 mg of activated florisil and then transferred from the solid sorbent to an SPME fiber in the HS mode. A small volume of solvent is added to the adsorbent to favor this process. The selection of the adsorbent, as well as the optimization of certain parameters affecting the SPME, is performed using an experimental design strategy. Linearity is studied by external calibration in a wide range of concentrations using gas chromatography coupled to three different detection systems: electron capture detection, micro-electron capture detection, and mass spectrometry. An analysis of variance with a lack-of-fit test is run to validate the calibration data. Breakthrough of the adsorbent was studied sampling from 0.5 to 10 m(3) air, demonstrating that 1 m(3) air could be sampled without losses of pyrethroids. Quantitative recoveries are obtained at three concentration levels, with adequate repeatability. Limits of detection of the method are estimated at the sub-ng/m(3) level in most cases, well below the regulatory limits. Finally, several real indoor samples are collected and analyzed by the proposed method. Identification and quantitation of all target analytes present in the room air are possible.  相似文献   
8.
A method based on solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) has been optimized for the determination of fragrance allergens in water samples. This is the first study devoted to this family of cosmetic ingredients performed by SPME. The influence of parameters such as fibre coating, extraction and desorption temperatures, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mixed-level factorial design, which allowed the study of the main effects as well as two-factor interactions. Excluding desorption temperature, the other parameters were, in general, very important for the achievement of high response. The final procedure was based on headspace sampling at 100 °C, using polydimethylsiloxane/divinylbenzene fibres. The method showed good linearity and precision for all compounds, with detection limits ranging from 0.001 to 0.3 ng mL−1. Reliability was demonstrated through the evaluation of the recoveries in different real water samples, including baby bathwater and swimming pool water. The absence of matrix effects allowed the use of external standard calibration to quantify the target compounds in the samples. The proposed procedure was applied to the determination of allergens in several real samples. All the target compounds were found in the samples, and, in some cases, at quite high concentrations. The presence and the levels of these chemicals in baby bathwater should be a matter of concern. Baby exposure to fragrance allergens and other cosmetic ingredients through the daily bath  相似文献   
9.
A solid-phase microextraction (SPME) method for the ultra-trace determination of brominated phenols in aqueous samples has been developed and is reported for the first time to the best of our knowledge. 3,5,3',5'-tetrabromobisphenol A (TBBPA), the most widely used brominated flame retardant, and other phenolic flame retardants in commercial use, such as 2,4-dibromophenol (2,4-DBP), 2,4,6-tribromophenol (TBP) and pentabromophenol (PBP) have been included as target analytes. The analytical procedure involves the in situ acetylation-SPME and gas chromatography-mass spectrometry (GC-MS) determination of the target analytes. A multi-factor categorical experimental design was created to study the main parameters affecting the extraction efficiency, allowing also the evaluation of interaction effects between factors. The factors studied were type of fiber, extraction mode, exposing the fiber directly into the sample (DSPME) or into the headspace over the sample (HSSPME), and extraction temperature. Carboxen-polydimethylsiloxane (CAR-PDMS) fiber appeared to be the most suitable of the five fibers tested for the extraction of most compounds, excluding PBP and TBBPA for which polydimethylsiloxane (PDMS) was the most efficient coating. The highest response was achieved for both fibers sampling in headspace mode at 100 degrees C. In order to test the linearity of the method, calibration studies were performed with both CAR-PDMS and PDMS coatings. For both fibers, the method was linear in a range of 2 orders of magnitude, giving relative standard deviation (RSD%) below 10% for most compounds and detection limits at the low pg/mL level. In addition, the feasibility of the method for simultaneous determination of chlorinated and brominated phenols was studied. Finally, the method was applied to several real samples including tap water and effluent and influent waste water samples from an urban treatment plant, in which several phenolic compounds, such as phenol, methylphenols and chlorophenols, could be detected and quantified.  相似文献   
10.
Fragrances are ubiquitous pollutants in the environment, present in the most of household products, air fresheners, insecticides and cosmetics. Commercial perfumes may contain hundreds of individual fragrance chemicals. In addition to the widespread use and exposure to fragranced products, many of the raw fragrance materials have limited available health and safety data. Because of their nature as artificial fragrances, inhalation should be considered as an important exposure pathway, especially in indoor environments. In this work, a very simple, fast, and sensitive methodology for the analysis of 24 fragrance allergens in indoor air is presented. Considered compounds include those regulated by the EU Directive, excluding limonene; methyl eugenol was also included due to its toxicity. The proposed methodology is based on the use of a very low amount of adsorbent to retain the target compounds, and the rapid ultrasound-assisted solvent extraction (UAE) using a very low volume of solvent which avoids further extract concentration. Quantification was performed by gas chromatography coupled to mass spectrometry (GC–MS). The influence of main factors involved in the UAE step (type of adsorbent and solvent, solvent volume and extraction time) was studied using an experimental design approach to account for possible factor interactions. Using the optimized procedure, 0.2 m−3 air are sampled, analytes are retained on 25 mg Florisil, from which they are extracted by UAE (5 min) with 2 mL ethyl acetate. Linearity was demonstrated in a wide concentration range. Efficiency of the total sampling-extraction process was studied at several concentration levels (1, 5 and 125 μg m−3), obtaining quantitative recoveries, and good precision (RSD < 10%). Method detection limits were ≤0.6 μg m−3. Finally, the proposed method was applied to real samples collected in indoor environments in which several of the target compounds were determined.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号