首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
化学   11篇
物理学   2篇
  2012年   1篇
  2011年   1篇
  2008年   1篇
  2000年   1篇
  1989年   1篇
  1988年   2篇
  1987年   1篇
  1983年   1篇
  1981年   1篇
  1978年   1篇
  1975年   1篇
  1967年   1篇
排序方式: 共有13条查询结果,搜索用时 0 毫秒
1.
The extraction of Al(III) and Zn(II) from an aqueous solution with two water-in-oil microemulsions, one containing di(2-ethylhexyl)phosphoric acid (DEHPA), was investigated to aid the understanding of the role of the extractant and the metal specific characteristics in the mechanism of microemulsion extraction. The extraction of Al with the DEHPA microemulsion increased by a factor of about 10 with respect to that in the conventional DEHPA system, whereas the extraction of Zn was lower than that in the single DEHPA system. Extraction with the DEHPA-free microemulsion was very low, showing that metal ion solubilization was not important in the mechanism of microemulsion extraction. It is proposed that the effect of the mixed microemulsion on the metal distribution coefficient is the result of the balance between a decrease in the complexation reaction yield due to the interaction between butanol and DEHPA, and the adsorption of the metal complex at the macro- and microinterfaces. The former leads to a decrease in Zn(II) extraction and the latter to Al(III) extraction synergism. Copyright 2000 Academic Press.  相似文献   
2.
The application of adsorption, precipitation and extraction thin-layer chromatography to the identification of block copolymers, determination of their homogeneity (mixtures of homopolymers), and evaluation of their compositional homogeneity by one- and two-dimensional, multistage and gradient methods, is described. To detect the polymers on the thin-layer plate, various methods of detection are used, including those specific for each component of the block copolymer. Examples of analysis of the following block copolymers by thin-layer chromatography are reported: PS-PMMA, PS-PB, PS-PAN, PS-PBG, PI-PMS-PI, PMMA-PBMA, PMMA-PBG, PS-PEO.  相似文献   
3.
Institute of High-Molecular-Mass Compounds, Academy of Sciences of the USSR, Leningrad. Translated from Khimiya Prirodynkh Soedinenii, No. 6, pp. 869–870, November–December, 1988.  相似文献   
4.
5.
A combination of gel permeation chromatography (GPC), thin-layer chromatography (TLC) and pyrolysis gas chromatography (PGC) has been used for investigations of a polymethyl methacrylate-polystyrene-polymethyl methacrylate block copolymer. Continuous distribution of the polymer (40-mg sample) was attained according to the content of the styrene and methyl methacrylate units and of the block copolymer and according to the composition of the copolymer as functions of the hydrodynamic radius of the macromolecules. The polymer was subjected to a preliminary fractionation with an analytical gel chromatograph. The fractions were investigated by TLC, which permitted the separation of the block copolymer and the homopolymers. The composition of the fractions obtained by GPC and TLC was determined by PGC. As a result, it was possible to establish the composition of the block copolymer and its ratio to polymethyl methacrylate in each fraction. This investigation was based on a combination of highly effective fractionation by chromatographic methods with precise quantitative ratios obtained from Benoit's universal calibration graph and from determinations of the composition of the polymer fractions by PGC. The mechanism of the TLC of polymers, including the appearance of artefacts that distort the results of analysis, is also discussed.  相似文献   
6.
在航空航天领域,为了加速系统设计及测试进度,通常需要进行半实物实时仿真,即控制器用实物,受控对象采用数学模型。本文开发出了基于Matlab/Simulink的两相传热模块,并用其搭建了某机械泵驱动两相回路的实时动态模型。通过与实验的对比,验证了模型的可靠性,表明该模型满足实时要求,可以在下一步用于半实物仿真。  相似文献   
7.
8.
A new method for the determination of the molecular weight of proteins and peptides has been developed. It is based on microcolumn exclusion chromatography in trifluoroacetic acid on silica gel sorbents of different porosities with a linear molecular-weight calibration dependence in the range of 5 × 102 - 7 × 104 Da. It was shown that in this eluent proteins and peptides adopt the random-coil conformation and do not undergo hydrolysis for 2–3 days at room temperature.  相似文献   
9.
The algebraic structure of chiral anomalies ismade globally valid on non-trivial bundles by the introduction of a fixed background connection. Some of the techniques used in the study of the anomaly are improved or generalized, including a systematic way of generating towers of ??descent equations??.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号