排序方式: 共有17条查询结果,搜索用时 15 毫秒
1.
2.
Yan Zhou Jing-Zheng Song Franky Fung-Kei Choi Hai-Feng Wu Chun-Feng Qiao Li-Sheng Ding Suo-Lang Gesang Hong-Xi Xu 《Journal of chromatography. A》2009,1216(42):7013-7023
A statistic approach using response surface methodology (RSM) for optimization of the ultra-high performance liquid chromatography (UHPLC) gradient and ionization response of electrospray ionization mass spectrometry (ESI-MS) to analyze the main alkaloids from the plant matrices of six Meconopsi species is presented. The optimization was performed with Box–Behnken designs (BBD) and the multicriteria response variables were described using global Derringer's desirability. Four parameters of UHPLC and six major parameters of ESI-MS were investigated for their contribution to analytes separation and response, leading to a total of 27 and 54 experiments being performed for each instrument, respectively. Quantitative analysis of four main alkaloids in nine samples from six Meconopsis species was employed to evaluate the statistical significance of the parameters on UHPLC–QTOF/ESI-MS analytes response. The results indicated that the optimized UHPLC–QTOF-MS method is very sensitive with the limit of detections (LODs) ranging from 0.5 to 0.1 ng/ml. The overall intra-day and the inter-day variations were less than 2.45%. The recovery of the method was in the range of 94.3–104.8% with RSD less than 4.0%. This approach has important implication in sensitivity enhancement of the ultra-trace determination of alkaloids from complex matrixes in the fields of natural products, metabolomics and pharmacokinetics. 相似文献
3.
Andy Shun-Hoi CHEUNG Sammual Yu-Lut LEUNG Franky Ka-Wah HAU Vivian Wing-Wah YAM 《高等学校化学研究》2021,37(5):1079-1084
Alkynylplatinum(II) bzimpy complexes of trimethylammonium-benzylethynyl ligand have been synthesized and characterized. Complexes with long alkyl chains have been found to exhibit interesting self-assembly properties in the acetonitrile solution. The amphiphilic nature of the complexes has led to the formation of nanorods, as revealed by electron microscopy experiments. Further increasing the polarity of the solvent media has given rise to the enhancement of low-energy emission. 相似文献
4.
乙二醇中的钛加入浓硫酸后,在酸性介质中与过氧化氢(H2O2)发生配合显色反应,配合物的最大吸收峰位于410 nm处.对影响配合显色光度法测定钛含量的因素进行了考察,建立了乙二醇中的钛含量的测定方法,获得了满意的结果.该方法是一种简便、迅速、可靠的钛含量分析方法. 相似文献
5.
Identification of a specifically expressed modified form of novel PSP-94 protein in the secretion of benign prostatic hyperplasia. 总被引:1,自引:0,他引:1
6.
Madder A Li L De Muynck H Farcy N Van Haver D Fant F Vanhoenacker G Sandra P Davis AP De Clercq PJ 《Journal of combinatorial chemistry》2002,4(6):552-562
A series of peptidosteroid derivatives containing two independent peptide chains in which Ser and His are incorporated were synthesized by solid-phase peptide synthesis. The activity of the different compounds in the hydrolysis of the activated substrate NF31 was assessed in a stepwise fashion. First, the different resin-bound derivatives 6a-l and 6x-z were individually assayed for serine esterification in the absence of water. The use of a colored substrate allowed for a visual identification of the most active compounds. Through the inclusion of control substances, the involvement of histidine in the mechanism for serine acylation was shown. Second, the hydrolysis and methanolysis of the different acylated derivatives 8a-l and 8x were evaluated using UV spectroscopy, again indicating the involvement of histidine. The feasibility of applying the above procedures in a combinatorial context was proven via the screening of artificial libraries, created by mixing the different resin-bound peptidosteroid compounds. In this respect, the use of a photocleavable linker allowed for the unambiguous structural characterization of the selected members via application of single-bead electrospray tandem mass spectrometry. 相似文献
7.
Beaujuge PM Tsao HN Hansen MR Amb CM Risko C Subbiah J Choudhury KR Mavrinskiy A Pisula W Brédas JL So F Müllen K Reynolds JR 《Journal of the American Chemical Society》2012,134(21):8944-8957
Given the fundamental differences in carrier generation and device operation in organic thin-film transistors (OTFTs) and organic photovoltaic (OPV) devices, the material design principles to apply may be expected to differ. In this respect, designing organic semiconductors that perform effectively in multiple device configurations remains a challenge. Following "donor-acceptor" principles, we designed and synthesized an analogous series of solution-processable π-conjugated polymers that combine the electron-rich dithienosilole (DTS) moiety, unsubstituted thiophene spacers, and the electron-deficient core 2,1,3-benzothiadiazole (BTD). Insights into backbone geometry and wave function delocalization as a function of molecular structure are provided by density functional theory (DFT) calculations at the B3LYP/6-31G(d,p) level. Using a combination of X-ray techniques (2D-WAXS and XRD) supported by solid-state NMR (SS-NMR) and atomic force microscopy (AFM), we demonstrate fundamental correlations between the polymer repeat-unit structure, molecular weight distribution, nature of the solubilizing side-chains appended to the backbones, and extent of structural order attainable in p-channel OTFTs. In particular, it is shown that the degree of microstructural order achievable in the self-assembled organic semiconductors increases largely with (i) increasing molecular weight and (ii) appropriate solubilizing-group substitution. The corresponding field-effect hole mobilities are enhanced by several orders of magnitude, reaching up to 0.1 cm(2) V(-1) s(-1) with the highest molecular weight fraction of the branched alkyl-substituted polymer derivative in this series. This trend is reflected in conventional bulk-heterojunction OPV devices using PC(71)BM, whereby the active layers exhibit space-charge-limited (SCL) hole mobilities approaching 10(-3) cm(2) V(-1) s(-1), and yield improved power conversion efficiencies on the order of 4.6% under AM1.5G solar illumination. Beyond structure-performance correlations, we observe a large dependence of the ionization potentials of the polymers estimated by electrochemical methods on polymer packing, and expect that these empirical results may have important consequences on future material study and device applications. 相似文献
8.
Zhou Y Fung-Kei Choi F He ZZ Song JZ Qiao CF Liu X Ding LS Gesang SL Xu HX 《Journal of separation science》2010,33(23-24):3675-3682
A method that couples rapid, sensitive, reproducible and accurate ultra-performance LC (UPLC) with quadrupole-TOF-MS was established for the first simultaneous qualitative and quantitative analysis of phenolic compounds in Artemisia minor. Box-Behnken designs (BBDs) were applied as an effective tool to optimise major parameters that influence the resolution of UPLC, including three gradient steps and column temperature. Under optimal UPLC conditions, a total of 23 phenolic compounds in the crude methanol extracts of A. minor were well separated on a Waters Acquity UPLC BEH C(18) column (100×2.1?mm, 1.7?μm particle size) within 16.5?min, and the compounds were unequivocally or tentatively identified via comparisons with authentic standards and literature. In this study, a total of six major phenolic compounds were quantified in A. minor and the method was validated to be sensitive, precise and accurate within the LOD from 1.24 to 5.27?μg/mL, and the overall intra- and inter-day variations in detection were less than 3.76%. The recovery of the method ranged from 97.9 to 103.8% with RSDs that were less than 5.8%. These results demonstrate that this approach has the potential for quality control of A. minor and other Tibetan herbal medicines. 相似文献
9.
Zhou Y Li N Choi FF Qiao CF Song JZ Li SL Liu X Cai ZW Fu PP Lin G Xu HX 《Analytica chimica acta》2010,681(1-2):33-40
A rapid, but sensitive and selective method for simultaneous screening and quantification of toxic pyrrolizidine alkaloids (PAs) by ultra performance liquid-chromatography (UPLC) coupled with tandem mass spectrometry (MS/MS) on a tandem quadrupole mass spectrometer (TQ-MS) is described. This was accomplished by incorporating the precursor ion scan (PIS) acquisition and multiple reaction monitoring (MRM) acquisition in the same UPLC-MS/MS run. Notably, the developed PIS approach for detecting two pairs of characteristic product ions at m/z 120/138 or 168/150, allowed specific identification of toxic retronecine and otonecine types PAs. This PIS method is highly sensitive with over 10-fold sensitivity improvement upon previously published LC-MS method. Moreover, this new approach is suitable for high sample throughput and was applied to the screening and quantifying toxic PAs in 22 samples collected from seven Parasenecio species and four Senecio species. In addition, coupling the MRM with PIS approach generated quantitative results equivalent to those obtained by conventional MRM-only approach. This coupled MRM with PIS approach could provide both qualitative and quantitative results without the need of repetitive analyses. 相似文献
10.
Zhou Y He MF Choi FF He ZH Song JZ Qiao CF Li SL Xu HX 《Biomedical chromatography : BMC》2011,25(8):851-857
A high‐sensitivity ultra‐performance liquid‐chromatography (UPLC) coupled with tandem mass spectrometric method was developed for simultaneous quantification and confirmation of triptolide in both zebrafish embryos and the aqueous‐exposure solution on a tandem quadrupole mass spectrometer (TQ‐MS). This was achieved by performing quantification using the multiple reaction monitoring (MRM) acquisition with simultaneous characterization of the MRM peak using product ion confirmation (PIC) acquisition as it elutes from the chromatographic system. Separation was achieved on a 1.7 µm C18 UPLC column using 0.1% formic acid water–acetonitrile mobile phase with a cycle time of 6 min. The linear range of 0.115–360 ng/mL, and lower limits of detection of 0.02 ng/mL and quantification of 0.064 ng/mL were established. This method was successfully applied to determine the time course of triptolide absorption by zebrafish embryos and the amount of triptolide remaining in the culture medium after administration of two triptolide dosages at three time points. This coupled MRM with PIC approach could provide both qualitative and quantitative results without the need for repetitive analyses. This resulted in the reduction of further confirmative experiments and analytical time, and ultimately increased laboratory productivity. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献