排序方式: 共有121条查询结果,搜索用时 0 毫秒
1.
A sensitive and efficient method for trace analysis of some phenolic compounds using simultaneous derivatization and air‐assisted liquid–liquid microextraction from human urine and plasma samples followed by gas chromatography–nitrogen phosphorous detection 下载免费PDF全文
Mir Ali Farajzadeh Mohammad Reza Afshar Mogaddam Ali Akbar Alizadeh Nabil 《Biomedical chromatography : BMC》2015,29(12):1921-1931
In present study, a simultaneous derivatization and air‐assisted liquid–liquid microextraction method combined with gas chromatography–nitrogen phosphorous detection has been developed for the determination of some phenolic compounds in biological samples. The analytes are derivatized and extracted simultaneously by a fast reaction with 1‐flouro‐2,4‐dinitrobenzene under mild conditions. Under optimal conditions low limits of detection in the range of 0.05–0.34 ng mL?1 are achievable. The obtained extraction recoveries are between 84 and 97% and the relative standard deviations are less than 7.2% for intraday (n = 6) and interday (n = 4) precisions. The proposed method was demonstrated to be a simple and efficient method for the analysis of phenols in biological samples. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
2.
Summary In this study, a rapid and efficient semi-micro extraction procedure is presented for the extraction of some higher n-alkanes
from water and soil samples. In the case of water samples n-hexane was used as the organic phase in a phase volume ratio (volume
of aqueous phase/volume of organic phase) higher than 285, while in the case of soil samples, extraction with n-hexane was
carried out in the presence of an excess of 2 M NaCl solution. The extraction rate from soil samples is very high and is better
than Soxhlet extraction, comparable with supercritical fluid extraction. High preconcentration factor in water samples allows
the limits of detection to be in the ng.mL−1 level with the use of gas chromatographic analysis. Flame ionization detector was used for monitoring the analytes. The obtained
recoveries of all studied compounds from both water and soil samples are higher than 90%. This method was successfully used
to determine some n-alkanes in municipal wastewater and contaminated soil. 相似文献
3.
Mir Ali Farajzadeh Mortaza Ebrahimi Ali Ranji Elham Feyz Vali Bejani Amir Abbas Matin 《Mikrochimica acta》2006,153(1-2):73-78
High performance liquid chromatography (HPLC) and gas chromatography (GC) are introduced for analysis of polymer lubricants
(stearamide, oleamide and erucamide). In the HPLC method, a reverse phase octadecylsilane (ODS) column along with acetonitrile/methanol
(60:40) as a mobile phase were used. Detection of analytes was performed by a UV detector at 202 nm. The analysis time was
less than 8 min. In the GC method, polar capillary column and flame ionization detector (FID) were used for separations and
detection, respectively. The analysis time by GC was longer than HPLC and was about 30 min. Limits of detection, linear range
and repeatability of both methods are similar, but determination of oleamide in real samples by HPLC method is difficult due
to complexity of the initial part of HPLC chromatogram in polyethylene samples. That problem is not observed in the GC method.
Detection limits in both methods for all analytes are lower than 0.003% which are much lower than the amount of lubricants
in commercial polymers (0.05–0.2%). 相似文献
4.
Ali Akbar Fathi Mohammad Reza Afshar Mogaddam Saeed Mohammad Sorouraddin Mir Ali Farajzadeh Ali Mohebbi 《Journal of separation science》2023,46(17):2201055
This research aims to synthesize a specific and efficient sorbent to use in the extraction of apixaban from human plasma samples and its determination by high-performance liquid chromatography-tandem mass spectrometry. High specific surface area of metal-organic framework, magnetic property of iron oxide nanoparticles, selectively of molecular imprinted polymer toward the analyte, and the combination of dispersive solid-phase extraction method with a sensitive analysis system provided an efficient analytical method. In this study, first, a molecularly imprinted polymer combined with magnetic metal organic framework nanocomposite was prepared and then characterized using different techniques. Then the sorbent particles were used for selective extraction of the analyte from plasma samples. The efficiency of the method was improved by optimizing effective parameters. According to the validation results, wide linear range (1.02–200 ng mL−1), acceptable coefficient of determination (0.9938), low limit of detection (0.32 ng mL−1) and limit of quantification (1.02 ng mL−1), high extraction recovery (78%), and good precision (relative standard deviations ≤ 2.9% for intra- (n = 6) and interday (n = 6) precisions) were obtainable using the proposed method. These outcomes showed the high potential of the proposed method for screening apixaban in the human plasma samples. 相似文献
5.
6.
In this study, an extraction and preconcentration technique using solid-phase extraction (SPE) along with hollow fiber (HF) has been developed as an ultra-preconcentration technique for some triazole pesticides in aqueous samples. Triazole pesticides were employed as model compounds to assess the method and were monitored by gas chromatography-flame ionization detection (GC-FID). Initially, an aqueous solution of target analytes was passed through an RP-8 SPE cartridge and then the adsorbed analytes were eluted with μL amounts of toluene. The collected elute was slowly introduced into an HF that had one end blocked. This allowed precipitation inside the lumen and pores of the HF. Finally, the obtained HF was mounted on a home-made solid-phase microextraction syringe and entered into the GC injection port for thermal desorption-GC analysis. The effect of various experimental parameters including injection port temperature, desorption time, state of HF, washing solvent, elution solvent and its volume, sample volume, etc. were investigated for finding the optimum conditions. The calibration graphs were linear in the ranges of 2-1000 ng/mL (penconazole and hexaconazole), 5-1000 ng/mL (tebuconazole), 15-1000 ng/mL (triticonazole) and the detection limits (LODs) ranged from 0.6 to 4.5 ng/mL. The enhancement factors were in the range of 870-950. The relative standard deviations (RSD%) for five repeated experiments (C=250 ng/mL of each pesticide) varied from 4.5 to 8.7%. The relative recoveries obtained for analytes in grape juice samples, spiked with different levels of each pesticide, were in the range of 87-119%. 相似文献
7.
Mir Ali Farajzadeh Hessamaddin Sohrabi Ali Mohebbi Mohammad Reza Afshar Mogaddam 《Journal of separation science》2019,42(6):1273-1280
In this study, a new two–step extraction procedure based on the combination of a modified quick, easy, cheap, effective, rugged, and safe extraction method with a deep eutectic solvent based microwave‐assisted dispersive liquid–liquid microextraction has been developed for the extraction of multiclass pesticides in tomato samples before their analysis by gas chromatography with flame ionization detection. In this method, initially, an aliquot of tomato is crushed and diluted with deionized water. The mixture is then passed through a filter paper and its residue and aqueous phase are separated. Afterwards, acetonitrile as an extraction/disperser solvent is passed through the filter paper containing the refuse. The analytes remained in the refuse are extracted into the acetonitrile and then the obtained extract is mixed with a deep eutectic solvent. The obtained mixture is injected into the tomato juice and placed in a microwave oven for 15 s. Consequently, a cloudy state is formed and the extractant containing the analytes are sedimented at the bottom of the tube after centrifugation. Finally, 1 μL of the sedimented phase is removed and injected into the separation system. Under the optimum conditions, limits of detection and quantification were in the ranges of 0.42–0.74 and 1.4–2.5 ng/g, respectively. 相似文献
8.
Asghar Mardani Mohammad Reza Afshar Mogaddam Mir Ali Farajzadeh Ali Mohebbi Mahboob Nemati Mohammadali Torbati 《Journal of separation science》2020,43(18):3674-3682
A sample pretreatment method based on the combination of a three‐phase solvent extraction system and deep eutectic solvent‐based dispersive liquid–liquid microextraction has been introduced for the extraction of four organochlorine pesticides in cocoa samples before their determination by gas chromatography‐electron capture detection. A mixture of sodium chloride, acetonitrile, and potassium hydroxide solution is added to cocoa bean or powder. After vortexing and centrifugation of the mixture, the collected upper phase (acetonitrile) is removed and mixed with a few microliters of N,N‐diethanol ammonium chloride: pivalic acid deep eutectic solvent. Then it is rapidly injected into deionized water and a cloudy solution is obtained. Under optimum conditions, the limits of detection and quantification were found to be 0.011‐0.031 and 0.036‐0.104 ng/g, respectively. The obtained extraction recoveries varied between 74 and 92%. Also, intra‐ (n = 6) and interday (n = 4) precisions were less than or equal to 7.1% for the studied pesticides at a concentration of 0.3 ng/g of each analyte. The suggested method was applied to determine the studied organochlorine pesticide residues in various cocoa powders and beans gathered from groceries in Tabriz city (Iran) and aldrin and dichlobenil were found in some of them. 相似文献
9.
Solid-Phase Microextraction Gas Chromatography for Determination of Some Organophosphorus Pesticides 总被引:1,自引:0,他引:1
A simple and rapid solid-phase microextraction (SPME) method is presented based on activated charcoal–PVC fiber for determination of some organophosphorus pesticides from aqueous samples in direct mode SPME. After optimization of the experimental variables affecting SPME of the target compounds from aqueous solutions, the proposed method was applied to determine pesticides in fruit juice. The analytes in this procedure were preconcentrated for 15 min on the SPME fiber and subsequently desorbed by heating the fiber at 200 °C for 5 min in the GC injection port. Separation was on a capillary column GC followed by flame ionization detection. Recoveries of the pesticides studied in aqueous samples ranged 42%–63% and repeatability for all analytes was < 9% for a single fiber. Fiber-to-fiber reproducibility was < 18%. 相似文献
10.
Gas chromatographic determination of some phenolic compounds in fuels and engine oil after simultaneous derivatization and microextraction 下载免费PDF全文
Mir Ali Farajzadeh Adeleh Yadeghari Leila Khoshmaram Houshang Ghorbanpour 《Journal of separation science》2014,37(20):2966-2973
In this study, a simultaneous derivatization/air‐assisted liquid–liquid microextraction method has been developed for sample preparation of some phenolic compounds in fuels and engine oil. Analytes are transferred by back liquid–liquid extraction into NaOH solution and then are derivatized with butyl chloroformate and extracted simultaneously into carbon tetrachloride. The extracted derivatized analytes are analyzed using gas chromatography with flame ionization detection. The effect of extracting solvent type, derivatization agent and extraction solvent volumes, ionic strength of the aqueous solution, number of extraction cycles, etc., on the extraction efficiency is investigated. The calibration graphs are linear in the range of 3–10 000 μg/L. Enhancement factors, enrichment factors, and extraction recoveries are in the ranges of 497 to 1471, 571 to 991, and 60 to 109%, respectively. Detection limits are obtained in the range of 0.8 to 2.0 μg/L. Relative standard deviations for the extraction of each selected phenols are in the ranges of 2–4% for intraday (n = 6) and 3–6% (n = 5) for interday precisions for 200 μg/L. This technique is successfully applied for the extraction, preconcentration, and determination of the selected phenols in gasoline, kerosene, gas oil, and engine oil. 相似文献