首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   34篇
  免费   0篇
化学   9篇
数学   3篇
物理学   22篇
  2012年   1篇
  2008年   1篇
  2006年   1篇
  2005年   1篇
  2004年   1篇
  2002年   1篇
  2000年   5篇
  1999年   3篇
  1998年   2篇
  1996年   3篇
  1995年   2篇
  1993年   4篇
  1990年   1篇
  1987年   2篇
  1986年   1篇
  1979年   1篇
  1933年   1篇
  1932年   1篇
  1931年   2篇
排序方式: 共有34条查询结果,搜索用时 15 毫秒
1.
2.
3.
4.
5.
6.
7.
8.
For a monolayer of 2,3-di-phytanyl-sn-glycerol-1-tetraethylene glycol-D,L-a-lipoic acid ester lipid (DPTL) self-assembled (SAM) at a gold electrode surface we propose a new method to determine the charge number per adsorbed molecule and the packing density (area per molecule) in the monolayer. The method relies on chronocoulometry to measure the charge density at the SAM covered gold electrode surface. Two series of measurements have to be performed. In the first series, charge densities are measured for a monolayer transferred from the air-solution to the metal-solution interface using the Langmuir-Blodgett (LB) technique. This series of measurements allows one to determine charge numbers per adsorbed DPTL molecule. The second series is performed using a gold electrode covered with a self-assembled monolayer. The charge densities obtained in this series are then used to calculate the packing density with the help of charge numbers per adsorbed DPTL determined in the first series. The area per adsorbed molecule determined by the new method was compared to the area per molecule determined by the popular reductive desorption method. The molecular area determined with the new method is about 20% larger than the area calculated from the van der Waals model, which is a physically reasonable result. In contrast, the popular reductive desorption method gives an area per molecule 20% lower than the minimum estimated based on a van der Waals model. This is a physically unreasonable result. It is also shown that the charge numbers per adsorbed molecule depend on the electrode potential and may assume values smaller than the number of electrons participating in the reductive desorption step. An explanation of the origin of the "partial charge numbers" is provided. We recommend the new method be used in future studies of thiol adsorption at metal surfaces.  相似文献   
9.
Delvotest SP NT DA is designed to test milk for the presence of antibacterial substances, such as antibiotics. The test is made of an agar gel containing bacterial spores and a color indicator. The milk sample is added onto the agar gel, and the test is incubated at 64 degrees C. The principle of the test is based on the diffusion of possible inhibitory substances that may be present in the milk sample into agar. This reduces growth and acid production by the test organism, and delays or prevents the agar from changing color from purple to yellow. The Delvotest Accelerator is an automated system in which the plates containing the milk to be analyzed are placed for incubation. The Accelerator automatically detects the end of the incubation and reads the results. A sample containing antibiotic will be noted as "positive." A sample without antibiotics or with antibiotics at concentrations below detection level will be noted as "negative." The present report includes all technical details about the Delvotest SP NT DA, and the results of the validation study. The validation study demonstrates that the Delvotest SP NT DA conforms to the product performance claims and confirms the robustness of the test. The Delvotest SP NT DA is, therefore, granted Performance Tested Method certification.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号