首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   25篇
  免费   2篇
化学   22篇
物理学   5篇
  2023年   1篇
  2022年   5篇
  2021年   2篇
  2019年   1篇
  2018年   3篇
  2017年   3篇
  2016年   1篇
  2014年   3篇
  2011年   3篇
  2010年   1篇
  2007年   1篇
  2000年   1篇
  1998年   1篇
  1975年   1篇
排序方式: 共有27条查询结果,搜索用时 15 毫秒
1.
2.
Aspirin (ASP) and cilostazol (CST) are used as a combination in pharmaceutical formulations for treatment of strokes. Salicylic acid (SAL) is considered to be one of the main synthesis impurities and a degradation product of ASP. On the other hand, the main related impurities of CST are CST related A, B, and C (CST-RA, CST-RB, and CST-RC), respectively. Furthermore, as high efficiency and less elution are the basic requirements of high-speed chromatographic separation, so, a comparative study of two simple, precise, and accurate reversed-phase HPLC and UPLC methods was developed and validated for simultaneous estimation of ASP and CST in bulk and capsules in the presence of SAL, CST-RA, CST-RB, and CST-RC. A Eurospher II C18 (250?×?4.6?mm2, 5?µm) for HPLC method and an Agilent Zorbax Eclipse Plus C18 (50?×?2.1?mm2, 1.8?µm) for UPLC method were used. A gradient mobile phase of 20?mM anhydrous KH2PO4 buffer solution (containing 0.2% triethylamine (TEA), v/v) with pH adjusted to 2.9 using orthophosphoric acid (solution A) and acetonitrile (solution B) mixed in different proportions for HPLC and UPLC methods was prepared. Flow rate was set to 1.0 and 0.3?mL min?1 for HPLC and UPLC methods, respectively, and the detection was performed for both methods at 210?nm. It worth noting that the proposed UPLC-DAD assay exhibited relatively much more precision, sensitivity, specificity, and economic and chromatographic separation superiority than proposed HPLC-UV assay. Both developed methods were compared with reference methods to prove its applicability and are suitable for purity assessment of ASP and CST in bulk and capsules.  相似文献   
3.
A rapid and precise LC method was developed for the simultaneous determination of aliskiren hemifumarate (ALS), amlodipine besylate (AML) and hydrochlorothiazide (HCZ) using acetonitrile:25 mM octane sulfonic acid sodium salt monohydrate in water (60:40 v/v) as the mobile phase. The flow rate was maintained at 1.2 mL min?1 on a stationary phase composed of Supelco, Discovery® HS (C18) column (25 cm × 4.6 mm, 5 μm). Isocratic elution was applied throughout the analysis. Detection was carried out at λ max (232 nm) at ambient temperature. The method was validated according to ICH guidelines. Linearity, accuracy and precision were satisfactory over the concentration ranges of 32–320, 2–44 and 4–64 μg mL?1 for ALS, AML and HCZ, respectively. LOD and LOQ were estimated and found to be 0.855 and 2.951 μg mL?1, respectively, for ALS, 0.061 and 0.202 μg mL?1, respectively, for AML as well as 0.052 and 0.174 μg mL?1, respectively, for HCZ. The method was successfully applied for the determination of the three drugs in their co-formulated tablets. The results were compared statistically with reference methods and no significant difference was found. The developed method is specific and accurate for the quality control and routine analysis of the cited drugs in pharmaceutical preparations.  相似文献   
4.
A binary mixture of ciprofloxacin hydrochloride (CIP) and metronidazole (MET) was determined by five simple and accurate methods, without prior separation. In the first method, CIP was determined by second derivative spectrophotometric method ((2)D) by measuring the amplitude at 282 nm (zero ordinate value of MET). On the other hand, the determination of MET was based on isosbestic point technique, where the total content of the mixture was determined at 294.5 nm (isosbestic point), then the content of MET could be calculated by subtraction. The second method was first derivative ratio spectrophotometric method ((1)DD) where the total amplitude at 261 and 285 nm and the amplitude at 295.5 nm were selected to simultaneously determine CIP and MET in binary mixture, respectively. The third method was based on dual wavelength analysis, in which two wavelengths were selected, at which the absorbances of the other component were the same. The fourth method depends on using Q-analysis method (absorbance ratio) which involves the formation of Q-absorbance equation using the respective absorptivity values at 294.5 nm (isosbestic point) and 281.5 nm (λ(max) of CIP). The fifth method is partial least-squares (PLS) chemometric technique for determination of CIP and MET. The developed methods were successfully applied to the analysis of CIP and MET in laboratory prepared mixtures and tablets with good recoveries and their validation was carried out following the International Conference on Harmonization (ICH) guidelines. The results obtained were statistically compared with each other showing no significant difference with respect to accuracy and precision.  相似文献   
5.
Molecular Diversity - In view of the anticonvulsant activity reported for phthalazine derivatives as non-competitive AMPA receptor antagonists, a new series of phthalazine-1,4-diones (2–12)...  相似文献   
6.
A nicotinamide-based derivative was designed as an antiproliferative VEGFR-2 inhibitor with the key pharmacophoric features needed to interact with the VEGFR-2 catalytic pocket. The ability of the designed congener ((E)-N-(4-(1-(2-(4-benzamidobenzoyl)hydrazono)ethyl)phenyl)nicotinamide), compound 10, to bind with the VEGFR-2 enzyme was demonstrated by molecular docking studies. Furthermore, six various MD simulations studies established the excellent binding of compound 10 with VEGFR-2 over 100 ns, exhibiting optimum dynamics. MM-GBSA confirmed the proper binding with a total exact binding energy of −38.36 Kcal/Mol. MM-GBSA studies also revealed the crucial amino acids in the binding through the free binding energy decomposition and declared the interactions variation of compound 10 inside VEGFR-2 via the Protein–Ligand Interaction Profiler (PLIP). Being new, its molecular structure was optimized by DFT. The DFT studies also confirmed the binding mode of compound 10 with the VEGFR-2. ADMET (in silico) profiling indicated the examined compound’s acceptable range of drug-likeness. The designed compound was synthesized through the condensation of N-(4-(hydrazinecarbonyl)phenyl)benzamide with N-(4-acetylphenyl)nicotinamide, where the carbonyl group has been replaced by an imine group. The in-vitro studies were consonant with the obtained in silico results as compound 10 prohibited VEGFR-2 with an IC50 value of 51 nM. Compound 10 also showed antiproliferative effects against MCF-7 and HCT 116 cancer cell lines with IC50 values of 8.25 and 6.48 μM, revealing magnificent selectivity indexes of 12.89 and 16.41, respectively.  相似文献   
7.
JPC – Journal of Planar Chromatography – Modern TLC - New stability-indicating thin-layer chromatography (TLC)—densitometry and reversed-phase liquid chromatography (RP-LC)...  相似文献   
8.
Ehab F. Elkady 《Talanta》2010,82(4):1604-1607
New, simple, rapid and precise reversed phase liquid chromatographic (RP-LC) method has been developed for the simultaneous determination of diclofenac potassium (DP) and methocarbamol (MT) in ternary mixture with guaifenesin (GF), degradation product of methocarbamol. Chromatographic separation was achieved on a Symmetry® Waters C18 column (150 mm × 4.6 mm, 5 μm). Gradient elution based on phosphate buffer pH (8)-acetonitrile at a flow rate of 1 mL min−1 was applied. The UV detector was operated at 282 nm for DP and 274 nm for MT and GF. Linearity, accuracy and precision were found to be acceptable over the concentration ranges of 0.05-16, 0.5-160 and 0.5-160 μg mL−1 for DP, MT and GF, respectively. The optimized method proved to be specific, robust and accurate for the quality control of the cited drugs in pharmaceutical preparation.  相似文献   
9.
In this paper various cation substituted Z‐hexaferrites, prepared by the usual ceramic procedure and firing at a relatively low temperature (980C) in a 2 atm. oxygen pressure are discussed. On these materials extensive studies were undertaken, X‐ray diffraction, IR absorption, scanning electronmicroscopy and a Mössbauer spectroscopy. Data obtained are explained, and discussed in details, leading to new information about the interaction of variant doped cation with the Z‐hexaferrite Fe sites.  相似文献   
10.
Copper mill materials from Utah and Nevada and rock cores from a geothermal drill hole at the Valies Grande Caldera in New Mexico were irradiated at the Los Alamos Scientific Laboratory with neutrons from a californium-252 source (about 1010 n s-1), and the capture γ-rays were measured. The copper response, based on the 6.89-MeV double escape line, agreed sufficiently well with the known chemical composition of the materials to indicate usefulness of this technique for exploring copper deposits and for monitoring metallurgical extraction processes.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号