排序方式: 共有127条查询结果,搜索用时 31 毫秒
1.
A simple, precise and accurate method is proposed for rapid determination of trace amounts of hydroxylamine based on the reaction of hydroxylamine with iodate in acidic media. The reaction of neutral red by the produced nitrite ion was used to monitor the reaction spectrophotometrically at 525 nm by a fixed time method. Hydroxylamine in the range of 0.0400-1.200 microg mL(-1) could be determined. The relative standard deviation for 10 determinations of 0.500 microg mL(-1) hydroxylamine was 1.81% and the limit of detection was 0.010 microg mL(-1). The proposed method was applied to the determination of hydroxylamine in water samples with satisfactory results. 相似文献
2.
Saeed Balalaie Elahe Kowsari Mehri S. Hashtroudi 《Monatshefte für Chemie / Chemical Monthly》2003,134(3):453-456
Summary. Three component condensation of alkylacetoacetates, primary amines, and alkyl cyanoacetates catalyzed by solid supports under
microwave irradiation gave N-alkyl 3-cyano-6-hydroxy-2(1H)-pyridinones with high yields. Upon carrying out the reaction under the same condition on acidic alumina, zeolite HY, silica
gel, and montmorillonite K-10, the best yields were achieved by silica gel.
Corresponding author. E-mail: balalaie@yahoo.com
Received August 28, 2002; accepted September 3, 2002 相似文献
3.
A new micelle-mediated phase preconcentration method for preconcentration of ultra-trace quantities of beryllium as a prior step to its determination by spectrophotometry has been developed. Chrome Azurol S (CAS) and cetyltrimethylammonium bromide (CTAB) were used as chelating agent and cationic surfactant, respectively. The method evaluates and eliminates the blank bias error present in such procedures using mean centering of ratio spectra. This procedure gives more accurate results than the traditional approach using absorbance values against reagent blank. The optimal extraction and reaction conditions were studied and the analytical characteristics of the method (e.g., limit of detection, linear range, preconcentration and improvement factors) were obtained. Linearity was obeyed in the range of 0.9-18.0 ng mL−1 (1.00 × 10−7-2.00 × 10−6 mol L−1) of beryllium. The detection limit of the method is 0.51 ng mL−1 (5.66 × 10−8 mol L−1) of beryllium. The interference effect of some anions and cations was also tested. The method was applied to the determination of beryllium in spring water samples. 相似文献
4.
Tayyebeh Madrakian Akram Esmaeili Azizeh Abdolmaleki 《Journal of Analytical Chemistry》2004,59(1):28-32
A new method for the rapid and sensitive determination of trace quantities of thiocyanate based on its Landolt effect on the bromate-hydrochloric acid reaction was developed. The induction period of the reaction is proportional to the SCN– concentration. The decolorization of methyl orange by the reaction products was used to monitor the reaction spectrophotometrically at 525 nm. We were able to determine thiocyanate in the range 2 × 10–7–4 × 10–5 M by this method. The relative standard deviation for 10 determinations of 1.5 × 10–6 M thiocyanate ion is 0.19% and the detection limit of the method was 7.00 × 10–8 M. The method was applied to the determination of thiocyanate in human blood serum and of saliva samples with satisfactory results. 相似文献
5.
6.
Green and one‐pot surface coating of iron oxide magnetic nanoparticles with natural amino acids and biocompatibility investigation 下载免费PDF全文
Hamed Nosrati Marziyeh Salehiabar Elahe Attari Soodabeh Davaran Hossein Danafar Hamidreza Kheiri Manjili 《应用有机金属化学》2018,32(2)
We report the synthesis of iron oxide magnetic nanoparticles (IONPs) coated with various natural amino acids (AAs) using a one‐pot reaction in an aqueous medium. Several AAs, which contained hydrophilic and hydrophobic groups, were selected to study their effects on size, morphology and toxicity of IONPs. Functionalized IONPs were characterized using X‐ray diffraction, differential scanning calorimetry, thermogravimetric analysis, Fourier transform infrared spectroscopy, and scanning and transmission electron microscopies. Furthermore, vibrating sample magnetometry analysis shows these nanoparticles have excellent magnetic properties. Cellular toxicity of IONPs was also investigated on HFF2 cell lines. The AA‐coated IONPs are non‐toxic and biocompatible. Natural AA‐coated IONPs show a potential for their development in in vitro and in vivo biomedical fields due to their non‐toxicity, good ζ‐potential and related small size and narrow size distribution. 相似文献
7.
Zahra Taji Ali A. Ensafi Elahe Heydari-Soureshjani Behzad Rezaei 《Electroanalysis》2021,33(2):304-313
In this work, a modified 3D-rGO/MWCNT with nickel and copper oxide nanoparticles were synthesized. The structural properties of this nanocomposite were investigated by several techniques. The fabricated sensor at optimum condition potential of +0.60 V (vs. Ag/AgCl) and a rotational rate of 1800 rpm gave a detection limit of 0.04 μmol L−1 with two dynamic ranges of 0.10–300 and 300–900 μmol L−1 glucose with high stability. The good accuracy of the fabricated sensor was proved in the determination of glucose in a blood sample (with recoveries between 95 % to 105 % and RSDs of 1.2 to 2.5 %). 相似文献
8.
9.
Abbas Afkhami Farzaneh Soltani-Felehgari Tayyebeh Madrakian Hamed Ghaedi Majid Rezaeivala 《Analytica chimica acta》2013
A new chemically modified carbon paste electrode was constructed and used for rapid, simple, accurate, selective and highly sensitive simultaneous determination of cadmium, copper and mercury using square wave anodic stripping voltammetry (SWASV). The carbon paste electrode was modified by N,N′-bis(3-(2-thenylidenimino)propyl)piperazine coated silica nanoparticles. Compared with carbon paste electrode, the stripping peak currents had a significant increase at the modified electrode. Under the optimized conditions (deposition potential, −1.100 V vs. Ag/AgCl; deposition time, 60 s; resting time, 10 s; SW frequency, 25 Hz; pulse amplitude, 0.15 V; dc voltage step height, 4.4 mV), the detection limit was 0.3, 0.1 and 0.05 ng mL−1 for the determination of Cd2+, Cu2+ and Hg2+, respectively. The complexation reaction of the ligand with several metal cations in methanol was studied and the stability constants of the complexes were obtained. The effects of different cations and anions on the simultaneous determination of metal ions were studied and it was found that the electrode is highly selective for the simultaneous determination of Cd2+, Cu2+ and Hg2+. Furthermore, the present method was applied to the determination of Cd2+, Cu2+ and Hg2+ in water and some foodstuff samples. 相似文献
10.
Tayyebeh Madrakian Abbas Afkhami Nahid Rezvani-jalal Mazaher Ahmadi 《Journal of the Iranian Chemical Society》2014,11(2):489-498
The potential removal and preconcentration of lead(II), cadmium(II), and chromium(III) ions from wastewaters were investigated and explored. Magnetite nanoparticles were chemically modified with p-nitro aniline. The aniline-coated magnetite nanoparticles (ANMNPs) were fully characterized by FT-IR, XRD, SEM, and TEM measurements. Batch studies were performed to address various experimental parameters for the removal and determination of these ions. ANMNPs showed high tendency to investigated metal ions, in this order: Cr(III) > Cd(II) > Pb(II), owing to the strong contribution of surface loaded aniline. The potential applications of ANMNPs adsorbent for removal and preconcentration of Pb(II), Cr(III), and Cd(II) from wastewaters as well as drinking tap water samples were successfully accomplished giving recovery values of (98–101 %), without any noticeable interference of the wastewater or drinking tap water matrices. 相似文献