排序方式: 共有19条查询结果,搜索用时 15 毫秒
1.
2.
3.
The Feynman path integral Monte Carlo approach has been coupled to the gauge including atomic orbital formalism in order to analyse the absolute magnetic shieldings of the benzene nuclei under the conditions of thermal equilibrium. The Hamiltonian employed in the derivation of ensemble averaged NMR quantities is of the Hartree-Fock type. The basis set used is of 6–31G quality. The spatial delocalization of the atoms leads to a deshielding of both types of benzene nuclei relative to the shieldings experienced at the minimum of the potential energy surface. This deshielding has to be traced back to bond length elongations in thermal equilibrium. The influence of the nuclear fluctuations on the NMR parameters of benzene is quantum driven up to temperatures of 400 K; classical fluctuations are of minor importance in this low-temperature window. 相似文献
4.
5.
6.
Zayed MA Khalil SM El-Qudaby HM 《Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy》2005,62(1-3):461-465
Two simple and accurate spectrophotometric methods are presented for the determination of anti-malarial drugs, chloroquine phosphate (CQP) and pyrimethamine (PYM), in pure and in different pharmaceutical preparations. The charge transphere (CT) reactions between CQP and PYM as electron donors and 2,3-dichloro-5,6-dicyano-p-benzoquinone (DDQ) pi-acceptor and iodine sigma-acceptor reagents to give highly coloured complex species have been spectrophotometrically studied. The optimum experimental conditions have been studied carefully. Beer' law is obeyed over the concentration range of 1.0-15 microg ml(-1) for CQP and 1.0-40 microg ml(-1) for PYM using I(2) and at 5.0-53 microg ml(-1) for CQP and 1.0-46 microg ml(-1) for PYM using DDQ reagents, respectively. For more accurate results, Ringbom optimum concentration range is calculated and found to be 10-53 and 8-46 microg ml(-1) for CQP and PYM using DDQ, respectively and 5-15 and 8-40 microg ml(-1) for CQP and PYM using iodine, respectively. The Sandell sensitivity is found to be 0.038 and 0.046 g cm(-2) for DDQ method and 0.0078 and 0.056 g cm(-2) for I(2) method for CQP and PYM, respectively which indicates the high sensitivity of both methods. Standard deviation (S.D.=0.012-0.014 and 0.013-0.015) and relative standard deviation (R.S.D.=0.09-1.4 and 1.3-1.5%) (n=5) for DDQ and I(2) methods respectively, refer to the high accuracy and precision of the proposed methods. These results are also confirmed by between day precision of percent recovery of 99-100.6%, and 98-101% for CQP and PYM by DDQ method and 99-102% and 99.2-101.4% for CQP and PYM by I(2) method respectively. These data are comparable to those obtained by British and American pharmacopoeias assay for the determination of CQP and PYM in raw materials and in pharmaceutical preparations. 相似文献
7.
8.
9.
10.