首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   92篇
  免费   0篇
化学   58篇
力学   4篇
数学   4篇
物理学   26篇
  2023年   1篇
  2022年   3篇
  2021年   2篇
  2019年   2篇
  2018年   3篇
  2017年   2篇
  2015年   1篇
  2014年   2篇
  2013年   17篇
  2012年   8篇
  2011年   3篇
  2010年   5篇
  2009年   2篇
  2008年   3篇
  2007年   1篇
  2006年   5篇
  2005年   3篇
  2004年   1篇
  2003年   2篇
  2002年   7篇
  2001年   4篇
  2000年   4篇
  1999年   2篇
  1996年   1篇
  1995年   1篇
  1993年   1篇
  1992年   1篇
  1990年   2篇
  1986年   2篇
  1985年   1篇
排序方式: 共有92条查询结果,搜索用时 109 毫秒
1.
The angular variations of the five-fold differential cross section obtained by using different wave functions of helium are compared with experimental data. It is found that in the coplanar geometry two kinematical arrangements, (i) equal energy sharing between the two ejected electrons with one of them ejected along the momentum transfer direction and the other along varying direction and (ii) the Bethe ridge condition with fixed sum of ejected electron energies and varying angle between them, are very sensitive to e-e correlations contained in the target wave function. This comparison has been used to show that open-shell class of wave functions better incorporate e-e correlations than the closed-shell class.  相似文献   
2.
Polymeric integrated-optical waveguides are prepared in a planar polymer chip by UV-laser lithographic methods. The waveguide samples are irradiated by an excimer laser at a wavelength Λ=248 nm with various irradiation parameters (different fluencies and irradiation doses). Mach-Zehnder interferometer is employed and the refractive index depth profiles of the waveguide samples are obtained. This profile covers two regions having exponential and Gaussian shapes. The model field distributions strongly depend on the refractive index of each region. The mode field distribution and the effective mode indices for each region have been calculated on the basis of a theoretical model and the experimentally measured data.  相似文献   
3.
The present work succeeded to develop new optional procedures to enhance the separation process of thorium and REEs. Selective precipitation of thorium with pyrophosphate was successfully attained for the upscale level in which, complete and efficient thorium separation (99%) was achieved with relatively low co-precipitation of REEs (average 15%) and Fe(III) (2.6%). On the other hand, promising and costless method has been developed to optimize the selective precipitation of REEs by adjusting the ratio of the free acids H2SO4 to H3PO4 at 5:1. It could be obviously demonstrated that about 65.3% of LREEs could be precipitated with a minor amount of thorium 11.9%. Finally, this proposed method could be successfully applied for production of Th and REEs with relatively high yield and purity in addition to low-cost–benefit.  相似文献   
4.
We apply the time-dependent theory to the collinear exchange reaction F + CH4 → FCH3 + H. We have performed detailed calculations on two-dimensional potential surfaces representing the ground electronic potentials of the collinear F + CH4 → FCH3 + H reaction, at incident energies. Transmission coefficients range from zero to unity, depending upon the incident energy. Normal modes of vibrations are displayed along the reaction path.  相似文献   
5.
Six oil soluble nonionic surfactants with different HLBs have been prepared. Their HLBs situate between 3.9 and 6.7. Transesterification was carried out for glycerol and triethanol amine with oleic acid at different moles to obtain six emusilifiers. They named glycerol momooleate (I), glycerol diooleate (II), glycerol trioleate (III), triethanol amine mono-, di- and tri-oleate (IV), (V,) and (VI). The chemical structure was confirmed using; the elemental analysis, FTIR and 1HNMR. They were evaluated as a primary emulsifiers (PE) for thdrilling fluids (oil base mud) comparing with a currently used primary emulsifier (Fc). The water in oil base mud (w/o emulsions) was prepared. The concentration of emulsifiers and their HLB exhibited interesting rheology properties including shear-thinning behavior, yield value, viscoelastic effects, thixtropy, gel strength, and filtration loss. The rheology properties of such emulsions strongly depended on the average size distribution of the dispersed droplets that could be varied both with the bulk concentration and HLB value of the emulsifiers. The interfacial and surface properties of these emulsifiers suggest that the droplet size of the dispersed phase and bulk concentration are strongly related to the HLB value of emulsifiers. The w/o emulsion (mud formulation) stability is sensitive to the droplet size of the dispersed phase and HLB value of the used emulsifier. The results were discussed on the light the chemical structure of the primary emulsifiers and the emulsion ingredients.  相似文献   
6.
An analytical method is described for the analysis of antazoline [2-(N-benzylanilinomethyl) imidazoline] using pmr. The procedure provides good quantitative results together with a very specific mean for identification of antazoline  相似文献   
7.
Two accurate, reliable, and highly sensitive spectrofluorimetric methods were developed for simultaneous determination of binary mixture gemfibrozil and rosiglitazone in human plasma without prior separation steps. The first method is based on synchronous fluorescence spectrometry using double scans. At Δλ = 27 nm, gemfibrozil yields detectable signal that is independent of the presence of rosiglitazone. Similarly, at Δλ = 120 nm the signal of rosiglitazone is not influenced by the presence of gemfibrozil. Signals at two wavelengths, 301 (Δλ = 27 nm) and 368 nm (Δλ = 120 nm) vary linearly with gemfibrozil and rosiglitazone concentrations over the range 100-700 ng mL−1 (for gemfibrozil) and 20-140 ng mL−1 (for rosiglitazone), respectively. The limits of detection (LOD) were 2.3 and 2.72 ng mL−1 for gemfibrozil and rosiglitazone, respectively. The second method is based on the technique of simultaneous equations (Vierodt's method), in which 258 nm was selected as the excitation wavelength. Two equations are constructed based on the fact that at (λEm2=302 nm of gemfibrozil) and (λEm2=369 nm of rosiglitazone) the fluorescence of the mixture is the sum of the individual fluorescence of gemfibrozil and rosiglitazone. The limits of detection (LOD) were 28.1 and 23.63 ng mL−1 for gemfibrozil and rosiglitazone, respectively. The proposed methods were successfully applied for the determination of the two compounds in synthetic mixtures and in human plasma with a good recovery.  相似文献   
8.
MHD mixed free-forced heat and mass convective steady incompressible laminar boundary layer flow of a gray optically thick electrically conducting viscous fluid past a semi-infinite inclined plate for high temperature and concentration differences is studied. A uniform magnetic field is applied perpendicular to the plate. The density of the fluid is assumed to reduce exponentially with temperature and concentration. The usual Boussinesq approximation is neglected due to the high temperature and concentration differences between the plate and the ambient fluid. The Rosseland approximation is used to describe the radiative heat flux in the energy equation. The boundary layer equations governing the flow are reduced to ordinary differential equations, which are numerically solved by applying an efficient technique. The effects of the density/temperature parameter n, the density/concentration parameter m, the local magnetic parameter Mx and the radiation parameter R are examined on the velocity, temperature and concentration distributions as well as the coefficients of skin-friction, heat flux and mass flux.  相似文献   
9.
A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of Terbinafine HCl (TRH) and linezolid (LNZ) in their pharmaceutical formulations. The proposed method is based on measuring the native fluorescence of the studied drugs in water at 336 nm after excitation at 275 nm for TRH and 375 nm after excitation at 254 nm for LNZ. The fluorescence–concentration plots were rectilinear over the range of 0.02–0.15 μg/mL for TRH and 0.5–5.0 μg/mL for LNZ. With lower detection limits of 3.0 and 110.0 ng/mL and a lower quantification limit of 9.0 and 320.0 ng/mL for TRH and LNZ, respectively. The method was successfully applied to the analysis of TRH in its commercial tablets, cream, gel and spray formulations and the results were in good agreement with those obtained with the official method. In addition the method was also applied to the analysis of LNZ in its capsule and I.V solution and the results were in good agreement with those obtained with the comparison method. The effect of sensitizers was studied. The method was extended to the determination of the studied drugs in spiked human plasma and the results were satisfactory.  相似文献   
10.
Two simple, accurate, and reliable spectrophotometric methods have been developed for the determination of 2 antiviral drugs, acyclovir (ACV) and ribavirin (RBV), in their pharmaceutical formulations. These methods are based on oxidation of the 2 drugs with either cerium (IV) ammonium sulfate (Method A) or potassium persulfate (Method B). The products of oxidation in both methods are coupled with 3-methylbenzothiazolin 2-one hydrazone, producing a deep blue color with a maximum absorption wavelength at 630 nm. In Method A, the absorbance-concentration plots were linear over the ranges of 5-50 and 10-60 microg/mL with detection limits of 0.18 microg/mL (8 x 10(-7) M) and 0.63 microg/mL (2.58 x 10(-6) M) for ACV and RBV, respectively. In Method B, the ranges were 5-45 and 20-50 microg/mL with detection limits of 0.11 microg/mL (4.88 x 10(-7) M) and 1.40 microg/mL (5.73 x 10(-6) M) for the 2 drugs, respectively. The molar absorptivities were 4.1 x 10(3) and 3.65 x 10(3) L/mol/cm in Method A and 5.03 x 10(3) and 3.97 x 10(3) L/mol/cm in Method B for the 2 drugs, respectively. The proposed methods were applied successfully for the determination of the 2 drugs in their pharmaceutical formulations. The percentage recoveries +/- standard deviation were 99.57 +/- 0.86 and 100.82 +/- 0.46 for ACV; 99.41 +/- 1.08 and 100.35 +/- 1.03 for RBV. The results obtained were compared statistically with those given by official methods and showed no significant differences regarding accuracy and precision.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号