首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   46篇
  免费   4篇
化学   43篇
晶体学   1篇
物理学   6篇
  2016年   4篇
  2015年   2篇
  2014年   1篇
  2013年   6篇
  2012年   5篇
  2011年   3篇
  2010年   1篇
  2009年   4篇
  2008年   5篇
  2007年   5篇
  2006年   2篇
  2005年   2篇
  2004年   1篇
  2002年   4篇
  1999年   2篇
  1997年   1篇
  1990年   1篇
  1979年   1篇
排序方式: 共有50条查询结果,搜索用时 31 毫秒
1.
A sensitive, accurate and precise liquid chromatography/tandem mass spectrometry (LC/MS(2)) method was developed for the quantification of salmeterol in the urine of horses. The method consists of a liquid-liquid extraction with tert-butylmethyl ether and isopropanol at pH 12 after enzymatic hydrolysis. The extracts are analysed using an LC/MS system equipped with an electrospray ionisation (ESI) probe. Method validation showed excellent linearity, specificity, accuracy, precision and intra-laboratory repeatability and reproducibility. The limit of quantitative detection was 0.25 ng/mL and the limit of detection was 0.125 ng/mL. The excretion profile was determined after administration of 500 microg salmeterol (Serevent) to four standard-bred mares via a metered dose inhaler (MDI) with an Equinehaler adapter. Salmeterol was detected from 1 h until 12 h post-administration. Maximum urinary concentrations varied between 2.3 and 14.9 ng/mL.  相似文献   
2.
Due to their performance enhancing properties, use of anabolic steroids (e.g. testosterone, nandrolone, etc.) is banned in elite sports. Therefore, doping control laboratories accredited by the World Anti-Doping Agency (WADA) screen among others for these prohibited substances in urine. It is particularly challenging to detect misuse with naturally occurring anabolic steroids such as testosterone (T), which is a popular ergogenic agent in sports and society.  相似文献   
3.
Testosterone undecanoate (T‐C11) can be used by athletes in order to improve performance. After oral intake, T‐C11 is rapidly metabolized, hampering discrimination between exogenous and endogenous testosterone. A possible alternative is to detect the intact ester in hair. A method based on liquid chromatography–tandem mass spectrometry was developed for the determination of T‐C11 in hair. The sample procedure consisted of digestion of 200 mg of pulverized hair with tris(2‐carboxyethyl)phosphine hydrochloride and liquid–liquid extraction with n‐pentane. Several parameters such as the mobile phase, the ionization source and the washing step were optimized. The method was validated at different spiked levels obtaining satisfactory values for accuracy (between 92 and 102%) with relative standard deviations lower than 7% and a limit of detection of 0.2 ng/g. The applicability of the method was checked by the analysis of three samples from patients using T‐C11. A peak for the analyte was detected in all samples with concentrations between 0.4 and 8.4 ng/g. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
4.
The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, β2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min.  相似文献   
5.
Anti‐doping laboratories need to be aware of evolutions on the steroid market and elucidate steroid metabolism to identify markers of misuse. Owing to ethical considerations, in vivo and in vitro models are preferred to human excretion for nonpharmaceutical grade substances. In this study the chimeric mouse model and human liver microsomes (HLM) were used to elucidate the phase I metabolism of a new steroid product containing, according to the label, methylstenbolone. Analysis revealed the presence of both methylstenbolone and methasterone, a structurally closely related steroid. Via HPLC fraction collection, methylstenbolone was isolated and studied with both models. Using HLM, 10 mono‐hydroxylated derivatives (U1–U10) and a still unidentified derivative of methylstenbolone (U13) were detected. In chimeric mouse urine only di‐hydroxylated metabolites (U11–U12) were identified. Although closely related, neither methasterone nor its metabolites were detected after administration of isolated methylstenbolone. Administration of the steroid product resulted mainly in the detection of methasterone metabolites, which were similar to those already described in the literature. Methylstenbolone metabolites previously described were not detected. A GC‐MS/MS multiple reaction monitoring method was developed to detect methylstenbolone misuse. In one out of three samples, previously tested positive for methasterone, methylstenbolone and U13 were additionally detected, indicating the applicability of the method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   
6.
A comprehensive screening method for the detection of prohibited substances in doping control is described and validated. This method is capable of detecting over 150 components mentioned on the list of the World Anti-Doping Agency including anabolic androgenic steroids, stimulants and all narcotic agents that are currently analysed using different analytical methods. The analytes are extracted from urine by a combined extraction procedure using freshly distilled diethyl ether and tert-butyl methyl ether as extraction solvents at pH 9.5 and 14 respectively. Prior to GC-MS analysis the residues are combined and derivatised using a mixture of N-methyl-N-trimethylsilyltrifluoroacetamide, NH(4)I and ethanethiol. The mass spectrometer is simultaneously operated in the full scan mode (mass range varies along with GC-oven temperature program) and in the selected ion monitoring mode. The obtained limits of detection are in compliance with the requirements set by the World Anti-Doping Agency. Besides narcotics, stimulants and anabolic androgenic agents, this method is also capable of detecting several agents with anti-estrogenic activity and some beta-agonists. This comprehensive screening method reduces the amount of urine needed and increases the sample throughput without a loss in sensitivity and selectivity.  相似文献   
7.
The suitability of liquid chromatography tandem mass spectrometry (LC-MS/MS) and gas chromatography mass spectrometry (GC-MS) for the elucidation of fluoxymesterone metabolism has been evaluated. Electrospray ionization (ESI) and collision induced dissociation (CID) fragmentation in LC-MS/MS and electron impact spectra (EI) in GC-MS have been studied for fluoxymesterone and two commercially available metabolites. MS(n) experiments and accurate mass measurements performed by an ion-trap analyser and a QTOF instrument respectively have been used for the elucidation of the fragmentation pathway. The neutral loss scan of 20 Da (loss of HF) in LC-MS/MS has been applied for the selective detection of fluoxymesterone metabolites. In a positive fluoxymesterone doping control sample, 9 different analytes have been detected including the parent compound. Seven of these metabolites were also confirmed by GC-MS including 5 previously unreported metabolites. On the basis of the ionization, the CID fragmentation, the accurate mass of the product ions and the EI spectra of these analytes, a tentative elucidation as well as a proposal for the metabolic pathway of fluoxymesterone has been suggested. The presence of these compounds has also been confirmed by the analysis of five other positive fluoxymesterone urine samples.  相似文献   
8.
A screening method for the urinary detection of 34 exogenous anabolic steroids has been developed. The method involves an enzymatic hydrolysis, liquid-liquid extraction and detection by liquid chromatography-tandem mass spectrometry. The use of some adducts such as [M+NH4]+, [M+CH3COO] and [M+H+MeOH]+ was necessary in order to detect some analytes at the required level (lower than 10 ng/ml). Two transitions were selected for each analyte. Different concentration factors have been studied in order to increase the sensitivity. A concentration factor of 50 was selected for the screening method although the high ion suppression observed under these conditions can hamper its application as a quantitative method. The method was validated and limits of detection were obtained by spiking ten different blank urine samples at five different concentration levels. Up to 29 analytes were detected in all spiked urines at the required level. Limits of detection between 1 and 10 ng/ml were obtained for most analytes which fulfil current requirements. The applicability of the method was shown by analysing positive samples.  相似文献   
9.
The ionization of 46 anabolic steroids has been studied. The absence of basic or acidic moieties in most of these analytes makes their direct ionization as [M + H]+ by atmospheric pressure interfaces difficult. The formation of adducts with different components of the mobile phase has been found to be an efficient way to ionize anabolic steroids by electrospray. Different mobile phases using methanol (MeOH) or acetonitrile as organic solvent and HCOOH, Na+ or NH4+ as additives have been tested to favor the adduct formation. A direct correlation between the chemical structure of the anabolic steroid and the possibility to ionize it in a particular chromatographic condition has been found. According to their ionization, anabolic steroids can be divided into seven different groups depending on both the nature and the relative position of their functional groups. The formation of different adducts such as [M + Na + MeOH]+ or [M + H + CH3 CN - H2O]+ is required in order to ionize some of these groups and the optimal mobile phase composition for each group of anabolic steroids is proposed. Despite the ionization limitations due to their chemical structure, most of tested anabolic steroids could be ionized using the adduct formation approach.  相似文献   
10.
A new screening procedure for 18 narcotics in urine for anti-doping purposes has been developed using liquid chromatography/triple quadrupole mass spectrometry (LC/MS). Electrospray ionization (ESI) was used as interface. Infusion experiments were performed for all substances to investigate their mass spectrometric behaviour in terms of selecting product specific ions. These product ions were then used to develop a tandem mass spectrometric method using selected reaction monitoring (SRM). For the LC/MS analysis, chromatography was performed on an octadecylsilane column. The total run time of the chromatographic method was 5.5 min. For the sample preparation prior to LC/MS analysis, the urine samples were liquid-liquid extracted at pH 9.5 after overnight enzymatic hydrolysis. Two extraction solvents were evaluated: dichloromethane/methanol 9/1 (v/v), which is currently used for the extraction of narcotics, and diethyl ether, used for the extraction of steroids. With diethyl ether the detection limits for all compounds ranged between 0.5 and 20 ng/mL and with the mixture containing dichloromethane the detection limits ranged between 0.5 and 10 ng/mL. Taking into account the minimum required performance limits of the World Anti-Doping Agency of 200 ng/mL for narcotics, diethyl ether can also be considered as extraction solvent for narcotics. Finally, the described method was applied to the analysis of urine samples previously found to contain narcotics by our routine gas chromatography/mass spectrometry (GC/MS) method.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏