排序方式: 共有27条查询结果,搜索用时 31 毫秒
1.
Alexopoulos T Allen C Anderson EW Areti H Banerjee S Beery PD Biswas NN Bujak A Carmony DD Carter T Cole P Choi Y De Bonte RJ Erwin AR Findeisen C Goshaw AT Gutay LJ Hirsch AS Hojvat C Kenney VP Lindsey CS LoSecco JM McMahon T McManus AP Morgan N Nelson KS Oh SH Piekarz J Porile NT Reeves D Scharenberg RP Stampke SR Stringfellow BC Thompson MA Turkot F Walker WD Wang CH Wesson DK 《Physical review letters》1990,64(9):991-994
2.
Lazarus EA Navratil GA Greenfield CM Strait EJ Austin ME Burrell KH Casper TA Baker DR DeBoo JC Doyle EJ Durst R Ferron JR Forest CB Gohil P Groebner RJ Heidbrink WW Hong R Houlberg WA Howald AW Hsieh C Hyatt AW Jackson GL Kim J Lao LL Lasnier CJ Leonard AW Lohr J La Haye RJ Maingi R Miller RL Murakami M Osborne TH Perkins LJ Petty CC Rettig CL Rhodes TL Rice BW Sabbagh SA Schissel DP Scoville JT Snider RT Staebler GM Stallard BW Stambaugh RD St John HE Stockdale RE Taylor PL Thomas DM 《Physical review letters》1996,77(13):2714-2717
3.
4.
5.
6.
7.
Gouveia CA Oliveira A Pinho S Vasconcelos C Carvalho F Moreira RF Dinis-Oliveira RJ 《Biomedical chromatography : BMC》2012,26(8):1041-1047
The development of analytical techniques that enable the use of hair as an alternative matrix for the analysis of drugs of abuse is useful for confirming the exposure in a larger time window (weeks to months, depending on the length of the hair shaft). In the present study a methodology aimed at the simultaneous quantification of cocaine and morphine in human hair was developed and validated. After decontamination, hair samples (20?mg) were incubated with a mixture of methanol/hydrochloric acid (2:1) at 65?°C overnight (~16?h) in order to extract the drugs of the matrix. Purification was performed by solid-phase extraction using mixed-mode extraction cartridges. After derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide, blank, standards and samples were analyzed by gas chromatography/electron impact-mass spectrometry (GC-EI/MS). The method proved to be selective, as there were no interferences of endogenous compounds with the same retention time as cocaine, morphine and ethylmorphine (internal standard). The regression analysis for both analytes showed linearity in the range 0.25-10.00?ng/mg with correlation coefficients ranging from 0.9989 to 0.9991. The coefficients of variation oscillated between 0.83 and 14.60%. The limits of detection were 0.01 and 0.02?ng/mg, and the limits of quantification were 0.03 and 0.06?ng/mg for cocaine and morphine, respectively. The proposed GC-EI/MS method provided an accurate and simple assay with adequate precision and recovery for the quantification of cocaine and morphine in hair samples. The proof of applicability was performed in hair samples obtained from drug addicts enrolled in a Regional Detoxification Treatment Center. The importance of hair samples is highlighted, since positives results were obtained when urine immunoassay analyses were negative. Copyright ? 2012 John Wiley & Sons, Ltd. 相似文献
8.
Extensive new high-temperature, high-resolution FTIR emission spectroscopy measurements for the five common isotopomers of GeO are combined with previous diode laser and microwave measurements in combined isotopomer analyses. New Dunham expansion parameters and an accurate analytical potential energy function are determined for the ground X1Sigma+ state. Copyright 1999 Academic Press. 相似文献
9.
Moreira PN de Pinho PG Baltazar MT Bastos ML Carvalho F Dinis-Oliveira RJ 《Biomedical chromatography : BMC》2012,26(3):338-349
Paraquat (PQ) is an herbicide implicated in numerous fatalities, mainly caused by voluntary ingestion. Several methods have been used to quantify PQ in plasma and urine samples of intoxicated humans as a predictor of clinical outcome. There is no validated method for the analysis of PQ in postmortem samples. Therefore, the aim of this study was to develop an analytical method, using gas chromatography–ion trap mass spectrometry (GC‐IT/MS) after solid‐phase extraction, to quantify PQ in postmortem samples, namely in whole blood, urine, liver, lung and kidney, to cover the routes of distribution, accumulation and elimination of PQ. The method proved to be selective as there were no interferences of endogenous compounds with the same retention time as PQ and ethyl paraquat (internal standard). The regression analysis for PQ was linear in the range 0–10 µg/mL. The detection limits ranged from 0.0076 µg/mL for urine to 0.047 µg/mL for whole blood, and the recoveries were suitable for forensic analysis. The proposed GC‐IT/MS method provided an accurate and simple assay with adequate precision and recovery for the quantification of PQ in postmortem samples. The proof of applicability was performed in two fatal PQ intoxications. A review of the analytical methods for the determination of quaternary ammonium herbicides is also provided for a better understanding of the presently available techniques. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
10.