排序方式: 共有34条查询结果,搜索用时 15 毫秒
1.
2.
3.
4.
B. Hathi P. M. Daniell M. Banaszkiewicz A. Hagermann M. R. Leese J. C. Zarnecki 《Journal of Thermal Analysis and Calorimetry》2007,87(2):585-590
This paper outlines the method of measurement
and analysis of the thermal conductivity instrument (THP) that has successfully
returned measurements from the atmosphere of Saturn’s moon Titan during
the descent of the Huygens probe on 14th January
2005.
The technique is validated by analysing laboratory calibration
data gathered by our instrument in three pure gases (nitrogen, methane, and
ethane) over Titan’s temperature range (90 to 180 K). Calibration results
show errors <1% compared to reference values when processed using this
method. 相似文献
5.
6.
Neitzel R Seixas N Olson J Daniell W Goldman B 《The Journal of the Acoustical Society of America》2004,115(1):237-245
Efforts to characterize nonoccupational noise exposures have focused primarily on infrequent, episodic events. Few studies have assessed noise levels resulting from routine daily activities. In the current study, 112 construction workers wore datalogging noise dosimeters and simultaneously completed activity logs during two phases of data collection. The 81 subjects monitored in phase 1 received logs listing numerous preselected occupational and nonoccupational activities, while the 31 subjects monitored in phase 2 used free-field logs and reported nonoccupational activities in greater detail. Nearly all of the 221,439 1-min intervals of nonoccupational L(eq) level and activity reporting were below 70 dBA; only a small percentage exceeded 80 dBA. The primary contributor to nonoccupational noise exposure was traveling in a car or bus, while time at home contributed the least. One hundred seventy 24-h L(eq) levels were computed from the 1-min noise level data. The percentage of phase 2 workday L(eq(24)) levels which exceeded 80 dBA was higher than that of the nonworkday levels. The mean L(eq(24)) level of phase 2 workdays was higher than that of nonworkdays, and the difference was statistically significant. Routine nonoccupational noise exposures contributed much less to total noise dose than occupational exposures in the subjects evaluated. 相似文献
7.
8.
D. Zhao J. J. Shane W. Daniell P. G. Harrison D. Goldfarb 《Applied magnetic resonance》1996,10(4):539-557
The role of the Cu(II) in the catalytic oxidation of CO over Cu/SnO2 with low Cu(II) content was studied by continuous wave EPR, electron spin echo envelope modulation (ESEEM) and hyperfine sublevel correlation (HYSCORE) spectroscopes. Three methods were employed for introducing the copper: (i) by coprecipitation, (ii) impregnation onto SnO2 gel and (iii) impregnation onto calcined SnO2. Two types of Cu(II) species were identified in these calcined Cu/SnO2 materials. Those belonging to the first type, termed B and C, exhibit highly resolved EPR spectra with well defined EPR parameters and are located within the bulk of the oxide. The other group comprises a distribution of surface Cu(II) species with unresolved EPR features and are referred to as S. While the latter were readily reduced by CO the former required long exposures at high temperatures (> 673 K). The specific interactions of the different Cu(II) species with CO were investigated through the determination of the13C hyperfine coupling of enriched13CO. The ESEEM spectra of calcined samples, generated either by coprecipitation or impregnation, show after the adsorption of CO signals at the Larmor frequencies of117, 119Sn and13C and at twice these Larmor frequencies. Although these signals indicate that117, 119Sn and13C are in the close vicinity of Cu(II), they cannot provide the hyperfine couplings of these nuclei. This problem was overcome by the application of the HYSCORE experiment. The 2D HYSCORE spectra show well resolved cross peaks which provide the hyperfine interaction of these nuclei. Simulations of the HYSCORE spectra yield for117, 119Sn an isotropic hyperfine constant,a iso, of ±4.0 MHz and an anisotropic component,T ?, of ±2.0 MHz. Pulsed ENDOR spectra also showed117, 119Sn signals which agree with the above values. The13C cross peaks yielda iso=±1.0 MHz andT ?=±2.0 MHz. Similar C cross peaks were observed in spectra of calcined Cu/SnO2 after the adsorption of CO2. Based on the same hyperfine couplings in the samples exposed to13CO and13CO2 the signals were assigned to surface carbonate species generated by part of the Cu(II) S type species rather then by species B and the role of the Cu(II) in the oxidation process is discussed. 相似文献
9.
Shumate WJ Mattern DL Jaiswal A Dixon DA White TR Burgess J Honciuc A Metzger RM 《The journal of physical chemistry. B》2006,110(23):11146-11159
We report spectroscopic characterization and unimolecular rectification (asymmetric electrical conduction) measurements of three donor-sigma-acceptor (D-sigma-A) compounds N-(10-nonadecyl)-N-(1-pyrenylmethyl)perylene-3,4,9,10-bis(dicarboximide) (1), N-(10-nonadecyl)-N-(4-[1-pyrenyl]butyl)perylene-3,4,9,10-bis(dicarboximide) (2), and N-(10-nonadecyl)-N-(2-ferrocenylethyl)perylene-3,4,9,10-bis(dicarboximide) (3). These molecules were arranged as one-molecule thick Langmuir-Blodgett monolayers between Au electrodes. In such an "Au | D-sigma-A | Au" sandwich, molecule 1 is a unimolecular rectifier, with rather small rectification ratios (between 2 and 3 at +/-1 V) that decrease upon cycling. Molecule 2 does not rectify. Molecule 3 rectifies, with a rectification ratio of between 14 and 28 at +/-1 V; the through-film rectification and currents persist, even with scans of +/-2 V, for up to 40 cycles of measurement. Qualitative arguments, based on a two-level rectification mechanism, are consistent with the current asymmetries observed in the monolayers of 1 and 3. 相似文献
10.
This study assessed the diagnostic test accuracy of magnetic resonance imaging (MRI) in the detection of partial- and full-thickness rotator cuff tears in the adult population. A systematic review was conducted of the following electronic databases: Cochrane Central Register of Controlled Trials, Medline, Embase, CINAHL, AMED, ISI Web of Science, Current Controlled Trials, National Technical Information Service, the National Institute for Health Research Portfolio, the UK National Research Register Archive and WHO International Clinical Trials Registry Platform database and reference lists of articles. All studies assessing the sensitivity and/or specificity of MRI for adult patients with suspected rotator cuff tear where surgical procedures were the reference standard were included in the study. A meta-analysis was performed to calculate pooled sensitivity, specificity, likelihood and diagnostic odds ratio values, and summary receiver operating characteristic plots were constructed. Forty-four studies were included. These included 2751 shoulders in 2710 patients. For partial-thickness rotator cuff tears, the pooled sensitivity and specificity values were 0.80 [95% confidence interval (CI): 0.79-0.84] and 0.95 (95% CI: 0.94-0.97), respectively. For full-thickness tears, the sensitivity and specificity values were 0.91 (95% CI: 0.86-0.94) and 0.97 (95% CI: 0.96-0.98), respectively. While there was no substantial difference in diagnostic test accuracy between MRIs reviewed by general radiologists and those reviewed by musculoskeletal radiologists, higher-field-strength (3.0 T) MRI systems provided the greatest diagnostic test accuracy. 相似文献