首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   0篇
化学   12篇
  2012年   1篇
  2008年   4篇
  2007年   3篇
  2006年   3篇
  2004年   1篇
排序方式: 共有12条查询结果,搜索用时 15 毫秒
1.
Reversed-phase liquid chromatography (LC) and LC/tandem mass spectrometry (LC/MS/MS) methods were developed and validated for the determination of etoricoxib in pharmaceutical dosage forms. The LC method was performed by reversed-phase chromatography on a Synergi fusion C18 column (150 x 4.6 mm id) maintained at ambient temperature. The mobile phase consisted of 0.01 M phosphoric acid, pH 3.0-acetonitrile (62 + 38, v/v) at a flow rate of 1.0 mL/min, and photodiode array detection at 234 nm was used. The chromatographic separation was obtained within 7.0 min, and calibration curves were linear in the concentration range of 0.02-150 microg/mL. The LC/MS/MS method was performed on a Luna C18 column (50 x 3.0 mm id). The mobile phase consisted of acetonitrile-water (95 + 5)-0.1% acetic acid (90 + 10, v/v). Detection was performed by positive electrospray ionization in the multiple reaction monitoring mode, monitoring the transitions 359.3 > 280.0 and 332.0 > 95.0 for etoricoxib and piroxicam (internal standard), respectively. The chromatographic separation was obtained within 2.0 min, and calibration curves were linear in the concentration range of 1-5000 ng/mL. Validation parameters, such as specificity, linearity, precision, accuracy, and robustness, were evaluated, which gave results within the acceptable range for both methods. Moreover, the proposed methods were successfully applied for routine quality control analysis of pharmaceutical products and showed significant correlation (r = 0.9999) of the results.  相似文献   
2.
A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of rupatadine in pharmaceutical dosage forms. The LC method was carried out on a Gemini C18 column (150 mm × 4.6 mm I.D.), maintained at 30 °C. The mobile phase consisted of ammonium acetate buffer (pH 3.0; 0.01 M) with 0.05% of 1-heptanesulfonic acid–acetonitrile (71.5:28.5, v/v), run at a flow rate of 1.0 mL min?1 and using photodiode array (PDA) detection at 242 nm. The chromatographic separation was obtained with retention time of 5.15 min, and was linear in the range of 0.5–400 μg mL?1 (r = 0.9999). The specificity and stability-indicating capability of the method was proven through the degradation studies and showing also, that there was no interference of the excipients. The accuracy was 100.39% with bias lower than 0.58%. The limits of detection and quantitation were 0.01 and 0.5 μg mL?1, respectively. Moreover, method validation demonstrated acceptable results for precision, sensitivity and robustness. The proposed method was applied for the analysis of pharmaceutical dosage forms assuring the therapeutic efficacy.  相似文献   
3.
An analytical method based on liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed and validated for the determination of ezetimibe in human plasma. Ezetimibe and etoricoxib (internal standard) were extracted from the plasma by liquid-liquid extraction and separated on a C18 analytical column (50 × 3.0 mm I.D.) with acetonitrile:water (85:15, v/v) as mobile phase. Detection was carried out by positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode. The chromatographic separation was obtained within 2.0 min and was linear in the concentration range of 0.25–20ng mL−1 for free ezetimibe and of 1–300ng mL−1 for total ezetimibe. The mean extraction recoveries for free and total ezetimibe from plasma were 96.14 and 64.11%, respectively. Method validation investigated parameters such as linearity, precision, accuracy, specificity and stability, giving results within the acceptable range. The proposed method was successfully applied to the quantitation of ezetimibe and its glucuronide in human plasma to support clinical and pharmacokinetic studies. Moreover, the method was used for the quality control analysis of pharmaceutical dosage forms. Revised: 4 January and 3 February 2006  相似文献   
4.
Enoxaparin is a low-molecular weight heparin used clinically for the prevention and treatment of venous and arterial thrombosis. An anti-factor Xa assay was used to evaluate the potency of the final drug preparation. Method validation investigated parameters such as the range, linearity (r2 = 0.9971), precision, accuracy, and robustness; the biological assay incorporated a chromogenic endpoint and detection at 405 nm. The method yielded good results with a quantitation limit of 0.037 IU/mL and a detection limit of 0.011 IU/mL. The results demonstrated the validity of the anti-factor Xa assay for the determination of enoxaparin.  相似文献   
5.
A stability-indicating MEKC was developed and validated for the analysis of rupatadine in tablet dosage forms, using nimesulide as internal standard. The MEKC method was performed on a fused-silica capillary (50 microm id; effective length, 40 cm). The BGE consisted of 15 mM borate buffer and 25 mM anionic detergent SDS solution at pH 10. The capillary temperature was maintained at 35 degrees C and the applied voltage was 25 kV. The injection was performed using the hydrodynamic mode at 50 mbar for 5 s, with detection by photodiode array detector set at 205 nm. The method was linear in the range of 0.5-150 microg/mL (r2=0.9996). The specificity and stability-indicating capability of the method were proven through degradation studies inclusive by MS, and showing also that there was no interference of the excipients and no increase of the cytotoxicity. The accuracy was 99.98% with bias lower than 1.06%. The LOD and LOQ were 0.1 and 0.5 microg/mL, respectively. The proposed method was successfully applied for the quantitative analysis of rupatadine in pharmaceutical formulations, and the results were compared to a validated RP-LC method, showing non-significant difference (p>0.05).  相似文献   
6.
A reversed-phase liquid chromatographic (LC) method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical dosage forms. The LC method was carried out on a Synergi fusion C18 column (150 mm x 4.6 mm id) maintained at 45 degrees C. The mobile phase consisted of phosphate buffer 0.03 M, pH 4.5-acetonitrile (35 + 65, v/v) run at a flow rate of 0.6 mL/min, and detection was made using a photodiode array detector at 234 nm. The chromatographic separation was obtained within 15.0 min, and calibration graphs were linear in the concentration range of 0.5-200 microg/mL. Validation parameters such as specificity, linearity, precision, accuracy, and robustness were evaluated, giving results within the acceptable range for both compounds. Moreover, the proposed method was successfully applied for the routine quality control analysis of pharmaceutical products.  相似文献   
7.

A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of rupatadine in pharmaceutical dosage forms. The LC method was carried out on a Gemini C18 column (150 mm × 4.6 mm I.D.), maintained at 30 °C. The mobile phase consisted of ammonium acetate buffer (pH 3.0; 0.01 M) with 0.05% of 1-heptanesulfonic acid–acetonitrile (71.5:28.5, v/v), run at a flow rate of 1.0 mL min−1 and using photodiode array (PDA) detection at 242 nm. The chromatographic separation was obtained with retention time of 5.15 min, and was linear in the range of 0.5–400 μg mL−1 (r = 0.9999). The specificity and stability-indicating capability of the method was proven through the degradation studies and showing also, that there was no interference of the excipients. The accuracy was 100.39% with bias lower than 0.58%. The limits of detection and quantitation were 0.01 and 0.5 μg mL−1, respectively. Moreover, method validation demonstrated acceptable results for precision, sensitivity and robustness. The proposed method was applied for the analysis of pharmaceutical dosage forms assuring the therapeutic efficacy.

  相似文献   
8.
A stability-indicating reversed-phase liquid chromatography (RP-LC) method was validated for the assessment of recombinant human interleukin-11 (rhIL-11), based on the ICH guidelines. The method was carried out on a Jupiter C(4) column (250 mm × 4.6 mm i.d.), maintained at 25°C. The mobile phase A consisted of 0.1% trifluoroacetic acid (TFA) and the mobile phase B was acetonitrile with 0.1% TFA, run at a flow rate of 1 mL/min, and using a photodiode array (PDA) detection at 214 nm. Separation was obtained with a retention time of 27.6 min, and was linear over the concentration range of 1-200 μg/mL (r(2) = 0.9995). Specificity was established in degradation studies, which also showed that there was no interference of the excipients. The accuracy was 100.22% with bias lower than 1.25%. Moreover, the in vitro cytotoxicity test of the degraded products showed non-significant differences (p > 0.05). The method was applied to the assessment of rhIL-11 and related proteins in biopharmaceutical dosage forms, and the results were correlated to those of a bioassay.  相似文献   
9.
The normocythemic mice bioassay was validated for the potency evaluation of the recombinant human erythropoietin (rhEPO) against the European Pharmacopoeia Biological Reference Preparation for erythropoietin. The bioassays were performed in 8-week-old female BALB/c mice, which received multiple daily injections of standard or sample solutions (3 + 3), for 4 days. The blood sampling was performed 24 h after the last injection and the reticulocytes were counted by automated flow cytometry. Method validation investigated parameters such as linearity, precision, accuracy, specificity, and robustness, giving results within the acceptable range. The dose-response curve was linear in the concentration range of 1-64 international units (IU)/mL, and the value of the determination coefficient (r2) was 0.9708. The bioassay was applied for the potency evaluation of rhEPO pharmaceutical products containing alfa or beta forms, expressed in different cell lines, giving biological potencies within 82.79 and 119.70% of the stated potency. The precision index calculated by the weight for the independent assays was >247. The results demonstrated the validity of the bioassay for the potency assessment of pharmaceutical formulations contributing to ensure the therapeutic efficacy of the biological medicine.  相似文献   
10.
A micellar electrokinetic chromatography (MEKC) method was validated for the analysis of ezetimibe. The method was carried out on a fused-silica capillary (50 microm i.d.; effective length, 40 cm). The background electrolyte consisted of a 25 mM borate buffer and 25 mM anionic detergent SDS (pH 9.75)/methanol (90:10, v/v). The capillary temperature was maintained at 35 degrees C, the applied voltage was 30 kV; the injection was performed using a pressure mode at 50 mbar for 5 s, with detection at 232 nm. The method was linear in the range of 2-150 microg/mL (R2=0.9999). The specificity and the stability-indicating capability were proven through degradation studies, which also showed that there was no interference of the excipients. The limits of quantitation and detection were 2 and 0.41 microg/mL, respectively. The method was applied for the analysis of ezetimibe pharmaceutical formulations, and the results were compared to those of the liquid-chromatography method.  相似文献   