排序方式: 共有31条查询结果,搜索用时 250 毫秒
1.
Kochocki JA Allison WW Alner GJ Ambats I Ayres DS Balka LJ Barr GD Barrett WL Benjamin D Border P Brooks CB Cobb JH Cockerill DJ Coover K Courant H Dahlin B DasGupta U Dawson JW Edwards VW Fields TH Kirby-Gallagher LM Garcia-Garcia C Giles RH Goodman MC Heller K Heppelman S Hill N Hoftiezer JH Jankowski DJ Johns K Joyce T Kafka T Litchfield PJ Lopez FV Lowe M Mann WA Marshak ML May EN McMaster L Milburn RH Miller W Napier A Oliver WP Pearce GF Perkins DH Peterson EA Price LE Roback D Rosen DB 《Physical review D: Particles and fields》1990,42(9):2967-2973
2.
3.
Daniel Karlsson Jakob Dahlin Åsa Marand Gunnar Skarping Marianne Dalene 《Analytica chimica acta》2005,534(2):263-269
A method for the determination of isocyanates as di-n-butyl amine (DBA) derivatives using tandem mass spectrometry (MS/MS) and electrospray ionisation (ESI) is presented. Multiple-reaction monitoring (MRM) of the protonated molecular ions and corresponding deuterium-labelled d9-DBA derivatives resulted in selective quantifications with correlation coefficients >0.998 for the DBA derivatives of isocyanic acid (ICA), methyl isocyanate (MIC), ethyl isocyanate (EIC), propyl isocyanate (PIC), phenyl isocyanate (PhI), 1,6-hexamethylene diisocyanate (HDI), 2,4-, 2,6-toluene diisocyanate (TDI), isophorone diisocyanate (IPDI), 4,4′-methylenediphenyl diisocyanate (MDI), 3-ring MDI, 4-ring MDI, HDI-isocyanurate, HDI-diisocyanurate, HDI-biuret and HDI-dibiuret. The instrumental precision for 10 repeated injections of a solution containing 0.1 μg ml−1 of the studied derivatives was <2%. Performing MRM of the product ion [DBA + H]+ (m/z = 130) from the protonated molecular ion resulted in the lowest detection limits, down to 10 amol (for TDI). Quantification of concentrations below 10−6 of the occupational exposure limit (OEL) for TDI during 10 min of air sampling was made possible. In an effort to control the formation of alkali adducts, addition of lithium acetate to the mobile phase and monitoring of lithium adducts was evaluated. Having lithium present in the mobile phase resulted in complete domination of [M + Li]+ adducts, but detection limits for the studied compounds were not improved. Different deuterium-labelled derivatives as internal standards were evaluated. (1) DBA derivatives of deuterium-labelled isocyanates (d4-HDI, d3-2,4-TDI, d3-2,6-TDI and d2-MDI), (2) d9-DBA derivatives of the corresponding isocyanates and (3) d18-DBA derivatives of the corresponding isocyanates. An increase in number of deuterium in the molecule of the internal standard resulted in an increase in instrumental precision and a decrease in correlation within calibration series. 相似文献
4.
5.
Background
Extracellular-signal regulated kinase (ERK1/2) is activated by nerve damage and its activation precedes survival and proliferation of Schwann cells. In contrast, activation of caspase 3, a cysteine protease, is considered as a marker for apoptosis in Schwann cells. In the present study, axonal outgrowth, activation of ERK1/2 by phosphorylation (p-ERK 1/2) and immunoreactivity of cleaved caspase 3 were examined after immediate, delayed, or no repair of transected rat sciatic nerves. 相似文献6.
7.
Dr. Robert Lizatović Marvin Assent Arjan Barendregt Jonathan Dahlin Dr. Anna Bille Katharina Satzinger Dagnija Tupina Prof. Albert J. R. Heck Dr. Stefan Wennmalm Dr. Ingemar André 《Angewandte Chemie (International ed. in English)》2018,57(35):11334-11338
Protein‐based encapsulation systems have a wide spectrum of applications in targeted delivery of cargo molecules and for chemical transformations in confined spaces. By engineering affinity between cargo and container proteins it has been possible to enable the efficient and specific encapsulation of target molecules. Missing in current approaches is the ability to turn off the interaction after encapsulation to enable the cargo to freely diffuse in the lumen of the container. Separation between cargo and container is desirable in drug delivery applications and in the use of capsids as catalytic nanoparticles. We describe an encapsulation system based on the hepatitis B virus capsid in which an engineered high‐affinity interaction between cargo and capsid proteins can be modulated by Ca2+. Cargo proteins are loaded into capsids in the presence of Ca2+, while ligand removal triggers unbinding inside the container. We observe that confinement leads to hindered rotation of cargo inside the capsid. Application of the designed container for catalysis was also demonstrated by encapsulation of an enzyme with β‐glucosidase activity. 相似文献
8.
DC Muddiman AP Null JC Hannis 《Rapid communications in mass spectrometry : RCM》1999,13(12):1201-1204
Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) has been used to determine the mass of a double-stranded 500 base-pair (bp) polymerase chain reaction (PCR) product with an average theoretical mass of the blunt-ended (i.e. unadenylated) species of 308 859.35 Da. The PCR product was generated from the linearized bacteriophage Lambda genome which is a double-stranded template. Utilization of ethanol precipitation in tandem with a rapid microdialysis step to purify and desalt the PCR product was crucial to obtain a precise mass measurement. The PCR product (0.8 pmol/μL) was electrosprayed from a solution containing 75% acetonitrile, 25 mM piperidine, and 25 mM imidazole and was infused at a rate of 200 nL/min. The average molecular mass and the corresponding precision were determined using the charge-states ranging from 172 to 235 net negative charges. The experimental mass and corresponding precision (reported as the 95% confidence interval of the mean) was 309 406 +/- 27 Da (87 ppm). The mass accuracy was compromised due to the fact that the PCR generates multiple products when using Taq polymerase due to the non-template directed 3'-adenylation. This results in a mixture of three PCR products with nearly identical mass (i.e. blunt-ended, mono-adenylated and di-adenylated) with unknown relative abundances that were not resolved in the spectrum. Thus, the experimental mass will be a weighted average of the three species which, under our experimental conditions, reflects a nearly equal concentration of the mono- and di-adenylated species. This report demonstrates that precise mass measurements of PCR products up to 309 kDa (500 bp) can be routinely obtained by ESI-FTICR requiring low femtomole amounts. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
9.
J Arnarp J Bielawski B M Dahlin O Dahlman C R Enzell T Pettersson 《Acta chemica Scandinavica (Copenhagen, Denmark : 1989)》1989,43(1):44-50
A series of alkyl and alkenyl substituted guaiacols, which comprise a group of biologically and organoleptically active compounds, have been synthesized. Mass spectra and GC retention times for these have been recorded and compared with those obtained for constituents of a weakly acidic fraction of smoke condensate derived from American blend type cigarettes. On the basis of these results, 25 guaiacols have been identified, 18 of which have not been detected in tobacco smoke condensate previously. 相似文献
10.
Bergström SK Dahlin AP Ramström M Andersson M Markides KE Bergquist J 《The Analyst》2006,131(7):791-798
Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices. 相似文献