首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   4篇
化学   16篇
  2022年   1篇
  2021年   1篇
  2020年   2篇
  2019年   1篇
  2018年   2篇
  2016年   3篇
  2014年   3篇
  2012年   2篇
  2010年   1篇
排序方式: 共有16条查询结果,搜索用时 31 毫秒
1.
MicroRNAs (miRs) have emerged as important clinical biomarkers with both diagnostic and prognostic value for relevant diseases, such as cancer. MiRs pose unique challenges for detection and are currently detected by northern blotting, real‐time PCR, and microarray techniques. These expensive, complicated, and time‐consuming techniques are not feasible for on‐site miR determination. In this study, amperometric magnetobiosensors involving RNA‐binding viral protein p19 as a selective biorecognition element were developed for miR quantification. The p19‐based magnetosensors were able to detect 0.4 fmol of a synthetic target and endogenous miR‐21 (selected as a model for its role in a wide variety of cancers) in only 2 h in total RNA extracted from cancer cells and human breast‐tumor specimens without PCR amplification and sample preprocessing. These results open up formidable perspectives for the diagnosis and prognosis of human cancers and for drug‐discovery programs.  相似文献   
2.
Two different D‐dimer disposable amperometric immunosensing designs based on indirect competitive or sandwich formats and the use of carboxylic acid‐modified magnetic beads (COOH‐MBs) and screen‐printed carbon electrodes (SPCEs) have been developed and compared. In both approaches, the resulting modified MBs were magnetically captured on the surface of a SPCE which was used as the transducer for the electrochemical detection at ?0.20 V upon addition of H2O2, and hydroquinone (HQ). Both configurations exhibited linear ranges of clinical usefulness and detection limits quite below the clinical threshold (0.5 µg mL?1 D‐dimer). The sandwich configuration has been successfully tested with serum samples.  相似文献   
3.
The preparation and performance of a disposable amperometric magneto-immunosensor, involving the use of a selective capture antibody immobilized on the surface of protein G-functionalized magnetic beads (ProtG-MBs) and screen-printed carbon electrodes (SPCEs), for the specific detection and quantification of tetracyclines (TCs) residues in milk is reported. A direct competitive immunoassay using a tracer with horseradish peroxidase (HRP) for the enzymatic labeling was performed. The amperometric response measured at −0.2 V vs. the silver pseudo-reference electrode of the SPCE upon the addition of H2O2 in the presence of hydroquinone (HQ) as redox mediator was used as transduction signal. The developed methodology showed very low limits of detection (in the low ppb level) for 4 tetracycline antibiotics tested in untreated milk samples, and a good selectivity against other antibiotic residues frequently detected in milk and dairy products. The usefulness of the magneto-immunosensor was demonstrated by analyzing UHT whole milk samples spiked with 44 ng mL−1 tetracycline (TC) as well as a reference milk containing a certified oxytetracycline (OTC) content. These features, together with the short analysis time (30 min), the simplicity, and easy automation and miniaturization of the required instrumentation make the developed methodology a promising alternative in the development of devices for on-site analysis.  相似文献   
4.
5.
Disposable amperometric magnetosensors, involving a mixture of modified-magnetic beads (MBs), for the multiplex screening of cephalosporins (CPHs), sulfonamides (SAs) and tetracyclines (TCs) antibiotic residues in milk are reported for the first time in this work. The multiplexed detection relies on the use of a mixture of target specific modified magnetic beads (MBs) and application of direct competitive assays using horseradish peroxidase (HRP)-labeled tracers. The amperometric responses measured at −0.20 V vs. the Ag pseudo-reference electrode of screen-printed carbon electrodes (SPCE) upon the addition of H2O2 in the presence of hydroquinone (HQ) as redox mediator, were used to monitor the extent of the different affinity reactions. The developed methodology, involving a simple and short pretreatment, allowed discrimination between no contaminated UHT and raw milk samples and samples containing antibiotic residues at the maximum residue limits (MRLs). The usefulness of the multiplexed magnetosensor was demonstrated by analyzing spiked milk samples in only 5 min. The results demonstrated that a clear discrimination of milk samples contaminated with antibiotics at their MRL level or their mixtures, allowing the identification of milk not complying with current legislation. These features make the developed methodology a promising alternative in the development of user-friendly devices for on-site analysis to ensure quality control for dairy products.  相似文献   
6.

Photoelectrochemical water splitting is mostly impeded by the slow kinetics of the oxygen evolution reaction. The construction of photoanodes that appreciably enhance the efficiency of this process is of vital technological importance towards solar fuel synthesis. In this work, Mo-modified BiVO4 (Mo:BiVO4), a promising water splitting photoanode, was modified with various oxygen evolution catalysts in two distinct configurations, with the catalysts either deposited on the surface of Mo:BiVO4 or embedded inside a Mo:BiVO4 film. The investigated catalysts included monometallic, bimetallic, and trimetallic oxides with spinel and layered structures, and nickel boride (NixB). In order to follow the influence of the incorporated catalysts and their respective properties, as well as the photoanode architecture on photoelectrochemical water oxidation, the fabricated photoanodes were characterised for their optical, morphological, and structural properties, photoelectrocatalytic activity with respect to evolved oxygen, and recombination rates of the photogenerated charge carriers. The architecture of the catalyst-modified Mo:BiVO4 photoanode was found to play a more decisive role than the nature of the catalyst on the performance of the photoanode in photoelectrocatalytic water oxidation. Differences in the photoelectrocatalytic activity of the various catalyst-modified Mo:BiVO4 photoanodes are attributed to the electronic structure of the materials revealed through differences in the Fermi energy levels. This work thus expands on the current knowledge towards the design of future practical photoanodes for photoelectrocatalytic water oxidation.

  相似文献   
7.
We propose the very first “Nernstian biosupercapacitor”, a biodevice based on only one redox polymer: poly(vinyl imidazole‐co‐allylamine)[Os(bpy)2Cl], and two biocatalysts. At the bioanode PQQ‐dependent glucose dehydrogenase reduces the Os3+ moieties at the polymer to Os2+ shifting the Nernst potential of the Os3+/Os2+ redox couple to negative values. Concomitantly, at the biocathode the reduction of O2 by means of bilirubin oxidase embedded in the same redox polymer leads to the oxidation of Os2+ to Os3+ shifting the Nernst potential to higher values. Despite the use of just one redox polymer an open circuit voltage of more than 0.45 V was obtained during charging and the charge is stored in the redox polymer at both the bioanode and the biocathode. By connecting both electrodes via a predefined resistor a high power density is obtained for a short time exceeding the steady state power of a corresponding biofuel cell by a factor of 8.  相似文献   
8.
Integrated amperometric biosensors for the determination of l-malic and l-lactic acids were developed by coimmobilization of the enzymes l-malate dehydrogenase (MDH) and diaphorase (DP), or l-lactate oxidase (LOX) and horseradish peroxidase (HRP), respectively, together with the redox mediator tetrathiafulvalene (TTF), on a 3-mercaptopropionic acid (MPA) self-assembled monolayer (SAM)-modified gold electrode by using a dialysis membrane. The electrochemical oxidation of TTF at +100 mV (vs. Ag/AgCl), and the reduction of TTF+ at −50 mV were used for the monitoring of the enzyme reactions involved in l-malic and l-lactic acid determinations, respectively. Experimental variables concerning the biosensors composition and the detection conditions were optimized for each biosensor. Good relative standard deviation values were obtained in both cases for the measurements carried out with the same biosensor, with no need of cleaning or pretreatment of the bioelectrodes surface, and with different biosensors constructed in the same manner. After 7 days of continuous use, the MDH/DP biosensor still exhibited 90% of the original sensitivity, while the LOX/HRP biosensor yielded a 91% of the original response after 5 days. Calibration graphs for l-malic and l-lactic were obtained with linear ranges of 5.2 × 10−7 to 2.0 × 10−5 and 4.2 × 10−7 to 2.0 × 10−5 M, respectively. The calculated detection limits were 5.2 × 10−7 and 4.2 × 10−7 M, respectively. The biosensors exhibited a high selectivity with no significant interferences. They were applied to monitor malolactic fermentation (MLF) induced by inoculation of Lactobacillus plantarum CECT 748T into a synthetic wine. Samples collected during MLF were assayed for l-malic and l-lactic acids, and the results obtained with the biosensors exhibited a very good correlation when plotted against those obtained by using commercial enzymatic kits.  相似文献   
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号