首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   0篇
化学   15篇
物理学   1篇
  2014年   1篇
  2011年   4篇
  2009年   1篇
  2007年   2篇
  2006年   1篇
  2000年   1篇
  1999年   1篇
  1996年   1篇
  1993年   1篇
  1992年   1篇
  1989年   1篇
  1978年   1篇
排序方式: 共有16条查询结果,搜索用时 31 毫秒
1.
Abstract— In order to obtain a better understanding of the kinetics of the Haber-Weiss reaction

often proposed as a source of OH radicals, we have measured the decomposition rate of H2O2 in aqueous solutions by y rays and for different pH values. This decomposition proceeds by a chain reaction involving the preceding one as the propagating step.
The rate constant found is to be
  相似文献   
2.
Stearoyl-CoA desaturase 1 (SCD1) plays a role in the development of obesity and related conditions, such as insulin resistance, and potentially also in neurological and heart diseases. The activity of SCD1 can be monitored using the desaturation index (DI), the ratio of product (16:1n-7 and 18:1n-9) to precursor (16:0 and 18:0) fatty acids. Here, different analytical strategies were applied to identify the method which best supports SCD1 biology. A novel effective approach was the use of the SCD1-independent fatty acid (16:1n-10) as a negative control. The first approach was based on a simple extraction followed by neutral loss triglyceride fatty acid analysis. The second approach was based on the saponification of triglycerides followed by fatty acid analysis (specific for the position of the double bond within monounsaturated fatty acids (MUFAs)). In addition to the analytical LC-MS assays, different matrices (plasma total triglyceride fraction and the very low-density lipoprotein (VLDL) fraction) were investigated to identify the best for studying changes in SCD1 activity. Samples from volunteers on a high-carbohydrate diet were analyzed. Both ultra HPLC (UHPLC)-MS-based assays showed acceptable accuracies (75–125 % of nominal) and precisions (<20 %) for the analysis of DI-specific fatty acids in VLDL and plasma. The most specific assay for the analysis of the liver SCD activity was then validated for specificity and selectivity, intra- and interday accuracy and precision, matrix effects, dilution effects, and analyte stability. After 3 days of high-carbohydrate diet, only the specific fatty acids in human plasma VLDL showed a significant increase in DI and associated SCD1 activity.  相似文献   
3.
SAR-943 (32-deoxo rapamycin) is a proliferation signal inhibitor via interaction with the mammalian target of rapamycin (mTOR). Most importantly, SAR-943 has improved chemical stability compared to rapamycin (sirolimus) and is currently under investigation as a drug coated on coronary stents. It was the goal of this study to identify the SAR-943 metabolites generated after incubation with human liver microsomes using high-resolution mass spectrometry (MS) and MS/iontrap (MS(n)) and comparison of fragmentation patterns of the metabolites with those of SAR-943 and other known rapamycin derivatives. Our study showed that SAR-943 is mainly hydroxylated and/or demethylated by human liver microsomes. The structures of the following metabolites were identified: O-demethylated metabolites: 39-O-desmethyl, 16-O-desmethyl and 27-O-desmethyl SAR-943; hydroxylated metabolites: hydroxy piperidine SAR-943, 11-hydroxy, 12-hydroxy, 14-hydroxy, 23-hydroxy, 24-hydroxy, 25-hydroxy, 46-hydroxy and 49-hydroxy SAR-943; didemethylated metabolites: 16,39-O-didesmethyl and 27,39-O-didesmethyl SAR-943; demethylated-hydroxylated metabolites: 39-O-desmethyl, 23- or 24-hydroxy and 39-O-desmethyl, hydroxy piperidine SAR-943 and dihydroxylated metabolites: 12-,23- or 24-dihydroxy SAR-943. In addition, several other demethylated-hydroxylated and dihydroxylated metabolites were detected. However, their exact structures could not be identified.  相似文献   
4.
5.
Employing capillary electrophoresis, the racemates of 29 acidic, neutral and basic dihydropyridines (DHPs) were separated by means of neutral and negatively charged cyclodextrins (CDs). Whereas the enantiomers of the acidic DHPs could be resolved with neutral CDs, mostly alpha- and beta-CD, the enantiomers of the neutral DHPs were only baseline-separated using the sulfobutyl ether-substituted beta-CD. Working in reversed polarity mode (detector at the anode) improved the peak shape and the resolution of the enantiomers. The racemates of the DHP bearing a secondary or tertiary amine function in the side chain at position 3 could be separated by using either the neutral gamma-CD or negatively charged CDs. The poor peak shape found with anionic CDs could be improved by the addition of methanol. The combination of gamma-CD and sulfated beta-CD allowed the detection of the minor enantiomer of lercanidipine (24) at less than 1% w/w.  相似文献   
6.
7.
8.
Opioids such as morphine are the cornerstone of pain treatment. The challenge of measuring the concentrations of morphine and its active metabolites in order to assess human pharmacokinetics and monitor therapeutic drugs in children requires assays with high sensitivity in small blood volumes. We developed and validated a semi-automated LC-MS/MS assay for the simultaneous quantification of morphine and its active metabolites morphine 3β-glucuronide (M3G) and morphine 6β-glucuronide (M6G) in human plasma and in dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the internal standards were the only manual steps. Morphine and its metabolites were separated on a Kinetex 2.6-μm PFP analytical column using an acetonitrile/0.1% formic acid gradient. The analytes were detected in the positive multiple reaction mode. In plasma, the assay had the following performance characteristics: range of reliable response of 0.25–1000 ng/mL (r 2 > 0.99) for morphine, 1–1,000 ng/mL (r 2 > 0.99) for M3G, and 2.5–1,000 ng/mL for M6G. In DBS, the assay had a range of reliable response of 1–1,000 ng/mL (r 2 > 0.99) for morphine and M3G, and of 2.5–1,000 ng/mL for M6G. For inter-day accuracy and precision for morphine, M3G and M6G were within 15% of the nominal values in both plasma and DBS. There was no carryover, ion suppression, or matrix interferences. The assay fulfilled all predefined acceptance criteria, and its sensitivity using DBS samples was adequate for the measurement of pediatric pharmacokinetic samples using a small blood of only 20–50 μL.  相似文献   
9.
Quantification of F(2)-isoprostanes is considered a reliable index of the oxidative stress status in vivo. Several immunoassays and chromatography/mass spectrometry-based assays are available for 15-F(2t)-isoprostane quantification. However, it remains unclear if results of immunoassays using different assays can be compared with those of liquid chromatography/mass spectrometry (LC/MS) assays. Previous studies comparing enzyme-linked immunosorbent assay (ELISA) and more specific gas chromatography/mass spectrometry assays have already indicated that ELISAs may overestimate 15-F(2t)-isoprostane concentrations in human plasma. Concentrations of 15-F(2t)-isoprostane in 25 human plasma and urine samples were measured by three commercially available ELISA assays (Assay Designs, Cayman Chemical and Oxford Biomedical Research) and compared with the concentrations measured with a validated, semi-automated high-throughput HPLC tandem mass spectrometry assay (LC/LC-MS/MS). All three ELISAs measured substantially higher 15-F(2t)-isoprostane concentrations (2.1-182.2-fold higher in plasma; 0.4-61.9-fold higher in urine) than LC/LC-MS/MS. Utilization of solid-phase extraction (SPE) columns, especially isoprostane affinity purification columns, brought ELISA isoprostane urine concentrations closer to the LC/LC-MS/MS results. However, SPE did not have much of an effect on ELISA plasma concentrations which remained significantly higher than corresponding LC/LC-MS/MS results. A poor correlation not only between LC/LC-MS/MS and immunoassay results, but also among the immunoassays was found. Especially in plasma, ELISAs grossly overestimate 15-F(2t)-isoprostane concentrations and are not comparable with each other or with LC/LC-MS/MS. It is most disturbing that a sample with relatively high concentrations measured with one ELISA may show low concentrations with another ELISA, and vice versa, potentially affecting the conclusions drawn from such data. The use of specific mass spectrometry-based assays seems advisable.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号