首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
化学   8篇
数学   1篇
物理学   4篇
  2013年   2篇
  2010年   1篇
  2008年   1篇
  2007年   1篇
  2006年   1篇
  2003年   1篇
  2002年   1篇
  1999年   1篇
  1995年   1篇
  1991年   1篇
  1984年   1篇
  1974年   1篇
排序方式: 共有13条查询结果,搜索用时 15 毫秒
1.
LetP={v 1,...,v n } be a set ofn jobs to be executed on a set ofm identical machines. In many instances of scheduling problems, if a jobv i has to be executed before the jobv j and both jobs are to be executed on different machines, some sort of information exchange has to take place between the machines executing them. The time it takes for this exchange of information is called a communication delay.In this paper we give anO(n) algorithm to find an optimal scheduling with communication delays when the number of machines is not limited and the precedence constraints on the jobs form a tree.  相似文献   
2.
CL Mehta 《Pramana》1984,23(3):327-332
Cumulant functions are introduced to describe the statistical state of a radiation field. These functions are simply related to the optical coherence functions but have some interesting features. It is shown that if the cumulant functions of all orders greater than some numberN 0 vanish then they also vanish for all orders greater than 2. Thermal field is the only field having this property. This property holds whether the field is described by a classical stochastic process or by a quantum density operator. Further the particular operator ordering used in defining these cumulant functions for the quantized field affects only the second order cumulant function. To describe the statistical state of a vector field such as partially polarized or unpolarized radiation, one would need to introduce cumulant tensors.  相似文献   
3.
We present a novel approach for the determination of activation energy for the unimolecular dissociation of a large (>50 atoms) ion, based on measurement of the unimolecular dissociation rate constant as a function of continuous-wave CO(2) laser intensity. Following a short ( approximately 1 s) induction period, CO(2) laser irradiation produces an essentially blackbody internal energy distribution, whose 'temperature' varies inversely with laser intensity. The only currently available method for measuring such activation energies is blackbody infrared radiative dissociation (BIRD). Compared with BIRD, FRAGMENT: (a) eliminates the need to heat the surrounding ion trap and vacuum chamber to each of several temperatures (each requiring hours for temperature equilibration); (b) offers a three-fold wider range of effective blackbody temperature; and (c) extends the range of applications to include initially cold ions (e.g., gas-phase H/D exchange). Our FRAGMENT-determined activation energy for dissociation of protonated bradykinin, 1.2 +/- 0.1 eV, agrees within experimental error to the value, 1.3 +/- 0.1 eV, previously reported by Williams et al. from BIRD experiments. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
4.
A packed capillary liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the identification of chemical warfare agents, their degradation products and related compounds in synthetic tabun samples and in soil samples collected from a former mustard storage site. A number of organophosphorus and organosulfur compounds that had not been previously characterized were identified, based on acquired high-resolution ESI-MS data. At lower sampling cone voltages, the ESI mass spectra were dominated by protonated, sodiated and protonated acetonitrile adducts and/or their dimers that could be used to confirm the molecular mass of each compound. Structural information was obtained by inducing product ion formation in the ESI interface at higher sampling cone voltages. Representative ESI-MS mass spectra for previously uncharacterized compounds were incorporated into a database as part of an on-going effort in chemical warfare agent detection and identification. The same samples were also analyzed by capillary column gas chromatography (GC)-MS in order to compare an established method with LC-ESI-MS for chemical warfare agent identification. Analysis times and full-scanning sensitivities were similar for both methods, with differences being associated with sample matrix, ease of ionization and compound volatility. GC-MS would be preferred for organic extracts and must be used for the determination of mustard and relatively non-polar organosulfur degradation products, including 1,4- thioxane and 1,4-dithiane, as these compounds do not ionize during ESI-MS. Diols, formed following hydrolysis of mustard and longer-chain sulfur vesicants, may be analyzed using both methods with LC-ESI-MS providing improved chromatographic peak shape. Aqueous samples and extracts would, typically, be analyzed by LC-ESI-MS, since these analyses may be conducted directly without the need for additional sample handling and/or derivatization associated with GC-MS determinations. Organophosphorus compounds, including chemical warfare agents, related compounds and lower volatility hydrolysis products may all be determined during a single LC-ESI- MS analysis. Derivatization of chemical warfare agent hydrolysis products and other compounds with hydroxyl substitution would be required prior to GC-MS analysis, giving LC-ESI-MS a definite advantage over GC-MS for the analysis of samples containing chemical warfare agents and/or their hydrolysis products.  相似文献   
5.
Desorption electrospray ionization mass spectrometry (DESI‐MS) has been applied to the direct analysis of sample media for target chemicals, including chemical warfare agents (CWA), without the need for additional sample handling. During the present study, solid‐phase microextraction (SPME) fibers were used to sample the headspace above five organophosphorus CWA, O‐isopropyl methylphosphonofluoridate (sarin, GB), O‐pinacolyl methylphosphonofluoridate (soman, GD), O‐ethyl N,N‐dimethyl phosphoramidocyanidate (tabun, GA), O‐cyclohexyl methylphosphonofluoridate (cyclohexyl sarin, GF) and O‐ethyl S‐2‐diisopropylaminoethyl methyl phosphonothiolate (VX) spiked into glass headspace sampling vials. Following sampling, the SPME fibers were introduced directly into a modified ESI source, enabling rapid and safe DESI of the toxic compounds. A SYNAPT HDMS? instrument was used to acquire time‐aligned parallel (TAP) fragmentation data, which provided both ion mobility and MSn (n = 2 or 3) data useful for the confirmation of CWA. Unique ion mobility profiles were acquired for each compound and characteristic product ions of the ion mobility separated ions were produced in the Triwave? transfer collision region. Up to six full scanning MSn spectra, containing the [M + H]+ ion and up to seven diagnostic product ions, were acquired for each CWA during SPME fiber analysis. A rapid screening approach, based on the developed methodology, was applied to several typical forensic media, including Dacron sampling swabs spiked with 5 µg of CWA. Background interference was minimal and the spiked CWA were readily identified within one minute on the basis of the acquired ion mobility and mass spectrometric data. Copyright © 2010 Crown in the right of Canada. Published by John Wiley & Sons, Ltd.  相似文献   
6.

Background  

Lack of adequate adjuvancy is a possible explanation for lack of vaccine immunogenecity. Immunostimulatory CpGs are potent vaccine adjuvants and may be an important component of the development vaccines, particularly those for which a cellular immune response is required for protection. We have previously demonstrated that CpG ODN co-administration with hepatitis B vaccine results in earlier, stronger and more sustained antibody responses to hepatitis B surface antigen in HIV infected individuals, and wished to determine if, in this population, helper T-cell responses were also enhanced.  相似文献   
7.
An attempted Diels-Alder reaction of 1-methoxycarbonylcyclopentadiene with cis-1,2-bis(phenylsulfonyl)ethylene gives a mixture of two sulfones, neither of which is the desired adduct. Instead a [1.5] sigmatropic rearrangement of the 1-methoxycarbonylcyclo-pentadiene precedes the 4 + 2 cycloaddition. Subsequent desulfonation also occurs in an unusual manner.  相似文献   
8.
Most prior analytical studies have dealt with the determination of chemical warfare agents in environmental or biological matrices that would typically be collected following battlefield use or in support of the Chemical Weapons Convention. These methods may be useful for some investigations, but may not be practical for indoor forensic investigations where chemical warfare agent use is suspected. There is a need for analytical methods for chemical warfare agent identification in office media, including flooring, wall surfaces, office fabrics and paper products, which would typically be collected in an office environment during forensic investigations. During this study, typical office environment media were spiked at the 4-20microg/g level with either a complex munitions grade sample of tabun (GA) or with a standard containing the three nerve agents, sarin (GB), cyclohexyl methylphosphonofluoridate (GF), soman (GD) and the nerve agent simulant, triethyl phosphate (TEP), to evaluate the potentials of liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) and liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) for forensic purposes. An emerging technique, desorption electrospray ionization (DESI-MS/MS), was also investigated for the direct determination of TEP, GB and GD sampled onto solid phase microextraction (SPME) fibers exposed to spiked office media. The spiked chemical warfare agents were recovered with varying efficiencies during this study, but in all cases sufficient chemical warfare agent was recovered for mass spectrometric identification purposes. Full high resolution mass spectra were acquired for all the chemical warfare agents in the continuum mode, which typically resulted in mass measurement errors of 0.001Da or less.  相似文献   
9.
Six alkyl alcohols were studied using thermospray mass Spectrometry. Whereas the dominant ion in the spectrum up to a repeller potential of 120 V was [M + NH4]+, above that potential [M + H]+ and fragment ions appeared. The fragments observed were largely due to hydrogen release from alkyl ions ([CnH2n+1]+ – H2 → [CnH2n-1]+) and loss of water or some other stable molecule from the same species. The results are compared with those from ionization of the same alcohols under electron impact and photoionization conditions and with results obtained for methanol under thermospray conditions.  相似文献   
10.
铌酸锶钡薄膜的微结构与电光性能的研究   总被引:3,自引:1,他引:2  
叶辉  Melanie M T Ho  Mak CL 《光学学报》2002,22(10):170-1175
本文叙述了使用溶胶凝胶法在MgO(0 0 1)的衬底上制备铌酸锶钡薄膜的过程 ,膜层厚度可达 5 μm。通过X射线衍射、摇摆曲线、扫描、拉曼散射光谱等方法研究了薄膜的微结构性能 ,实验发现 ,铌酸锶钡薄膜具有了较好的 (0 0 1)方向的优先取向性能 ,并且随着薄膜厚度的增加 ,其晶体取向性也会随之不断改进。熔石英的透明衬底上生长的SBN薄膜具有较大的电致双折射效应 ,其有效电光系数能够高达 6 6 2× 10 -11m/V。  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号