排序方式: 共有44条查询结果,搜索用时 15 毫秒
1.
Two pH-sensitive neutral carrier/PVC electrodes are used simultaneously for the measurement of pH by flow injection. One of these is based on the neutral carrier tridodecylamine and the other on octadecyl isonicotinate, and together they allow the pH range 1–13 to be covered. These electrodes have been used in a very low dispersion miniature potentiometric flow cell designed specifically for use in flow injection in conjunction with a multi-channel data acquisition system. The effects of the solution ionic strength and buffer capacity on the pH measurement are discussed. A flow-injection manifold is proposed which can be used for high-accuracy pH measurements without ionic strength adjustment of the sample and for simultaneous pH and ion concentration measurements with ionic strength adjustment. This has been tested on some synthetic samples for the simultaneous determination of potassium and calcium and the measurement of pH. 相似文献
2.
3.
A spectrophotometric flow-injection procedure is described for fluoride in aqueous samples. The method is based on the decrease in absorbance of the zirconium/alizarin red S complex at 520 nm; linear response is obtained for the range 0.1–10 mg l?1 fluoride at a sampling rate of 100 h?1. Aluminum(III), iron(III) and phosphate interfere. 相似文献
4.
The use of a polymer inclusion membrane in a paper-based sensor for the selective determination of Cu(II) 总被引:1,自引:0,他引:1
B. Manori Jayawardane Lilibeth dlC. Coo Robert W. Cattrall Spas D. Kolev 《Analytica chimica acta》2013
A disposable paper-based sensor (PBS) is described for the determination of Cu(II) in natural and waste waters at approximately 2 cents per measurement. The device makes use of a polymer inclusion membrane (PIM) to provide the selectivity for Cu(II). The PIM consists of 40 wt% di(2-ethlyhexyl) phosphoric acid (D2EHPA) as the carrier, 10 wt% dioctyl phthalate (DOP) as a plasticizer, 49.5 wt% poly(vinyl chloride) (PVC) as the base polymer and 0.5 wt% (m m−1) 1-(2′-pyridylazo)-2-naphthol (PAN) as the colourimetric reagent. High selectivity under mildly acidic conditions (HCl, pH 2.0) is achieved for Cu(II) in the presence of frequently encountered metal ions in natural and waste waters such as Fe(III), Al(III), Zn(II), Cd(II), Pb(II), Ca(II), Mg(II), and Ni(II). 相似文献
5.
A study of the factors affecting separation and detection of dissolved organic and inorganic phosphorus species found in waters sediments is reported. The system involved the use of gel filtration and flow injection analysis (FIA). Orthophosphate and myo-inositol hexakisphosphate, as model solutes representative of low molecular weight P (LMWP) and high molecular weight P (HMWP), were separated on a Sephadex G25 column incorporated into a flow-injection manifold which utilized photo-oxidation and spectrophotometry for detection of dissolved reactive phosphorus (DRP) and dissolved organic phosphorus (DOP). The influence of eluent pH and ionic strength on adsorption and anionic exclusion of the model solutes is described, and the optimum eluent composition and sample size are described. The method was used to determine LMWP and HMWP in natural and waste waters, and in sediment extracts. Potential limitations of this approach are discussed. 相似文献
6.
7.
This paper reports the first use of a polymer inclusion membrane (PIM) for on-line separation in flow injection analysis (FIA) involving simultaneous extraction and back-extraction. The FIA system containing the PIM separation module was used for the determination of Zn(II) in aqueous samples in the presence of Mg(II), Ca(II), Cd(II), Co(II), Ni(II), Cu(II), and Fe(III). The Fe(III) and Cu(II) interferences were eliminated by off-line precipitation with phosphate and on-line complexation with chloride, respectively. The concentration of Zn(II) was determined spectrophotometrically using 4-(2-pyridylazo) resorcinol (PAR). The optimal composition of the PIM consisted of 40% (m/m) di(2-ethlyhexyl) phosphoric acid (D2EHPA) as carrier, 10% (m/m) dioctyl phthalate (DOP) as plasticizer and 50% (m/m) poly(vinyl chloride) (PVC) as the base polymer. The optimized FIA system was characterized by a linear calibration curve in the range from 1.0 to 30.0 mg L−1 Zn(II), a detection limit of 0.05 mg L−1 and a relative standard deviation of 3.4% with a sampling rate of 4 h−1. Reproducible results were obtained for 20 replicate injections over a 5 h period which demonstrated a good membrane stability. The FIA system was applied to the determination of Zn(II) in pharmaceuticals and samples from the galvanizing industry and very good agreement with atomic absorption spectrometry was obtained. 相似文献
8.
9.
Four new sulfur-containing compounds based on pyridine, benzene, 1,8-naphthyridine and 1,10-phenanthroline have been synthesized. These molecules have been incorporated into a polymeric matrix as neutral carriers and evaluated as silver sensors. Two of the compounds (pyridine and benzene) show high selectivity for Ag(+). The sensor with the pyridine-based compound, in particular, shows near-Nernstian response and good sensitivity towards Ag(+) with a short response time (<10s), making it ideal for use in flow analysis. 相似文献
10.