首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   0篇
化学   12篇
物理学   3篇
  2012年   1篇
  2009年   1篇
  2008年   1篇
  2007年   2篇
  2006年   1篇
  2000年   2篇
  1995年   1篇
  1992年   2篇
  1988年   3篇
  1987年   1篇
排序方式: 共有15条查询结果,搜索用时 15 毫秒
1.
2.
The crystal structure and dielectric properties of slowly cooled A-site-deficient perovskites Li(x)Sr(x)La(2/3-x)□(1/3-x)TiO(3) (0.04 ≤ x ≤ 0.33) have been investigated by powder X-ray diffraction (XRD), impedance spectroscopy, and (7)Li NMR techniques. In this series, nominal vacancies decrease with Li content, but the total amount of A-site vacancies, n(t) = Li + □, participating in conduction processes remains basically constant. Rietveld analysis of the XRD patterns showed a change of symmetry from orthorhombic to tetragonal when the lithium and strontium contents increased above x = 0.08 and from tetragonal to cubic above x = 0.16. Structural modifications are mainly due to the cation vacancy ordering along the c axis, which disappear gradually when the lithium content increases. In agreement with the structural information, two lithium signals with different quadrupole constants are detected in (7)Li NMR spectra of orthorhombic/tetragonal phases, which have been associated with lithium in two crystallographic z/c = 0 and 1/2 planes of perovskites. In cubic samples, only a single narrow component, indicative of mobile species, was detected. Lithium motion was thermally activated, with activation energies going from 0.35 to 0.38 eV. Evolution of the bulk dc-conductivity preexponential factors along the series showed a maximum that has been first related to the dependence of lithium hopping on the lithium and vacancy concentrations. Finally, changes in the vacancy ordering, produced along the series, affect the dimensionality of the conductivity, indicating that not only the amount of vacancies but also its distribution are relevant.  相似文献   
3.
During method development for the determination of either isotretinoin, tretinoin and their 4-oxo-metabolites, or etretinate, acitretin and 13-cis-acitretin in plasma using high-performance liquid chromatography and column switching, recovery problems arose, when undiluted plasma samples were injected directly onto the precolumn. These recovery problems may be due to the strong binding of the retinoids to different plasma proteins. Measures to overcome this strong protein binding, such as variation of the injection solution composition and the purge mobile phase, were systematically investigated. Best recoveries were obtained by diluting of plasma with 9 mM sodium hydroxide-acetonitrile (8:2, v/v) and protein precipitation with ethanol for the isotretinoin and etretinate series, respectively, in combination with the use of a purge mobile phase containing ammonium acetate and 10-20% acetonitrile. Less effective was the use of a longer precolumn or heating of the precolumn.  相似文献   
4.
A fully automated and sensitive high-performance liquid chromatographic method, using on-line solid-phase extraction, automated column switching and ultraviolet detection, was developed for the third-generation retinoid (arotinoid) sumarotene (methyl p-[(E)-2-(5,6,7,8-tetrahydro-5,5,8,8-tetramethyl-2-naphthyl)propenyl]phe nyl sulphone; Ro 14-9706) and its Z-isomer. Nearly quantitative recoveries for human, rat and dog plasma were obtained by addition of acetonitrile (final content ca. 17%) to the plasma sample prior to injection. No isomerization was observed when the samples were stored in the autosampler for more than 20 h. The injection volume was 0.5 ml, resulting in quantification limits of 1 ng/ml for sumarotene and 2 ng/ml for the Z-isomer. More than 40 injections could be made on to one precolumn, allowing routine overnight injections. Using a 1-ml injection volume, the limit of quantification for sumarotene could be improved to 0.5 ng/ml. The method was applied to toxicokinetic studies in rats and dogs, and was used to monitor human plasma samples after repeated topical application. The method could also be adapted to etarotene (Ro 15-1570), which was used as an internal standard, and which is at present in clinical development.  相似文献   
5.
Natural toxins such as phytotoxins and mycotoxins have been studied in food and feed for decades, but little attention has yet been paid to their occurrence in the environment. Because of increasing awareness of the presence and potential relevance of micropollutants in the environment, phytotoxins and mycotoxins should be considered and investigated as part of the chemical cocktail in natural samples. Here, we compile chemical analytical methods to determine important phytotoxins (i.e. phenolic acids, quinones, benzoxazinones, terpenoids, glycoalkaloids, glucosinolates, isothiocyanates, phytosterols, flavonoids, coumestans, lignans, and chalcones) and mycotoxins (i.e. resorcyclic acid lactones, trichothecenes, fumonisins, and aflatoxins) in environmentally relevant matrices such as surface water, waste water-treatment plant influent and effluent, soil, sediment, manure, and sewage sludge. The main problems encountered in many of the reviewed methods were the frequent unavailability of suitable internal standards (especially isotope-labelled analogues) and often absent or fragmentary method optimization and validation.  相似文献   
6.
Because of their pronounced estrogenicity, resorcyclic acid lactones (RALs) are of concern in aqueous environments even at the low ng/L level. Therefore, we developed an accurate, precise and sensitive HPLC-MS/MS method to detect these mycotoxins in different aqueous environmental samples. The compounds investigated included zearalenone (ZON), alpha- and beta-zearalenol, zearalanone as well as alpha- and beta-zearalanol. The use of isotope labelled internal standards (in this case deuterated RAL-analogues) ensured an accurate quantification of the target analytes, independent of matrix compounds interfering with the analytes during ionisation and analyte losses occurring during sample preparation. Sample enrichment was carried out by solid-phase extraction (SPE) using Supelclean Envi-18 cartridges. Absolute method recoveries for all analytes ranged from 95 to 108%, 70 to 102%, and 76 to 109%, method detection limits from 0.5 to 2.1 ng/L, 0.4 to 1.1 ng/L, and 0.8 to 12.4 ng/L and precision from 3 to 14%, 2 to 13% and 4 to 16% in drainage water, river water and wastewater treatment plant (WWTP) effluent, respectively. The method was applied to verify the emission of RALs from a Fusarium graminearum infested crop field into the drainage system. Zearalenone was present in drainage water in concentrations up to 30 ng/L. So far, none of the other five investigated compounds have been detected.  相似文献   
7.
Immunoaffinity extraction has become increasingly important as a sample preparation and cleanup method in mycotoxin analysis. In this study, the antibody specificities of 3 commercial immunoaffinity columns (IACs) targeting zearalenone (ZON) were compared for alpha-zearalenol, beta-zearalenol, zearalanone, alpha-zearalanol, and beta-zearalanol. The recoveries of ZON and its 5 analogs were determined in triplicate when extracted from 10 mL circumneutral river water samples spiked with 20 ng analyte individually or in a mixture. The analytes were analyzed by means of electrospray ionization liquid chromatography/tandem mass spectrometry using deuterated internal standards for quantitation. Recoveries ranged from 69 to 115% for all analytes with relative standard deviations of 1-39%. Cross-reactivities for the analogs were > 80% when applied both individually and in a mixture. No significant competition effects were observed when the compounds were applied as a multianalyte mixture well below the stated IAC capacities. The results obtained here demonstrate that all IACs tested are highly cross-reactive towards the 5 ZON derivatives and may be applied for their simultaneous extraction or cleanup.  相似文献   
8.
9.
A HPLC method with automated column switching was developed and validated for the determination of Ro 63-1908 in rat and cynomolgus monkey plasma. Human plasma was used for calibration and was also included in the validation process. Ro 63-1908 belongs to a class of neuroprotective N-methyl-D-aspartate (NMDA) receptor blockers which were in development for the treatment of stroke and traumatic brain injury. The method involves deproteinisation of plasma samples with ethanol and direct injection of the supernatant (1.4 ml) into the HPLC column-switching system. To prevent a breakthrough of the analyte and the internal standard on the precolumn (Purospher RP-18, 75x4 mm) due to the high ethanol content, the injection solution was diluted, on-line, using an additional pump and a T-piece. 1% ammonium acetate-ethanol (100:2, v/v) was used as mobile phase for injection, as well as for on-line dilution, resulting in pre-concentration of the analyte and the internal standard on the precolumn. As Purospher RP-18 is a non-endcapped stationary phase with a special selectivity for amines, the analyte and the internal standard could then be selectively eluted with 30% acetonitrile (without any buffer in the mobile phase) and transferred to the analytical column [consisting of two coupled columns (125+250x4 mm) packed with Superspher 60 RP-select B], where they were separated by gradient elution and detected by fluorescence detection. Compared to the use of a 125 mm long precolumn and dilution of the supernatant with ammonium acetate prior to injection, the 75 mm precolumn and the on-line dilution procedure allowed about one third shorter run times (21 min) and, therefore, a higher sample throughput. The limit of quantification was 1 ng/ml using 0.4 ml plasma. The method was applied to more than 670 plasma samples from pharmacokinetic and toxicokinetic studies and is also suitable for other matrices and NMDA receptor blockers.  相似文献   
10.
An automated gradient high-performance liquid chromatographic method for the determination of etretinate, acitretin and 13-cis-acitretin in plasma was developed, using a column-switching technique. After protein precipitation with ethanol, 0.5 ml of the supernatant was injected onto a precolumn (17 mm x 4.6 mm I.D.), filled with 37-53 microns C18 Corasil. Polar plasma components were washed out using 1% ammonium acetate and 1% acetic acid-acetonitrile (8:2, v/v); the retained retinoids were then transferred to the analytical column (125 mm x 4 mm I.D., filled with 5-microns ODS material) in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. The limit of quantification was 2 ng/ml and the inter-assay precision in the concentration range 20-1000 ng/ml was between 0.9 and 4.0% for all three compounds. To optimize the recovery for etretinate (greater than 60%), protein was precipitated from plasma with ethanol before injection, instead of direct injection of plasma samples, and a mobile phase containing 20% acetonitrile, instead of pure water or buffer, was used.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号