全文获取类型
收费全文 | 73篇 |
免费 | 1篇 |
专业分类
化学 | 37篇 |
数学 | 2篇 |
物理学 | 35篇 |
出版年
2021年 | 2篇 |
2016年 | 3篇 |
2015年 | 1篇 |
2014年 | 2篇 |
2013年 | 3篇 |
2011年 | 1篇 |
2010年 | 1篇 |
2009年 | 1篇 |
2008年 | 3篇 |
2007年 | 3篇 |
2006年 | 1篇 |
2005年 | 1篇 |
2004年 | 1篇 |
2003年 | 2篇 |
2002年 | 3篇 |
2001年 | 2篇 |
2000年 | 6篇 |
1999年 | 3篇 |
1997年 | 3篇 |
1996年 | 4篇 |
1995年 | 7篇 |
1994年 | 6篇 |
1993年 | 5篇 |
1992年 | 6篇 |
1991年 | 1篇 |
1990年 | 1篇 |
1989年 | 1篇 |
1987年 | 1篇 |
排序方式: 共有74条查询结果,搜索用时 15 毫秒
1.
Maria Concetta Bruzzoniti Edoardo Mentasti Corrado Sarzanini Peter Hajs 《Journal of chromatography. A》1997,770(1-2):13-22
The retention behavior of biologically relevant monovalent (formic, acetic, propionic, lactic and pyruvic) and divalent (oxalic, malonic, succinic, fumaric, maleic and tartaric acids) car☐ylic acids together with inorganic analytes (chloride and sulphate) has been studied. The separation was performed on a latex-based strong anion-exchange resin using carbonate buffer systems in suppressed IC. The retention behaviour of analytes was investigated at different pH values and [HCO3−]+[CO32−] concentrations. A theoretical model, involving ion-exchange equilibria of sample and eluent anions, was derived and applied to the chromatographic data obtained. Chromatographic ion exchange selectivity values were determined and retention data were calculated for the anions using different carbonate eluent conditions. The average of errors between the predicted and the measured retention volumes of the analytes studied does not exceed 4.0%. The study effectively characteristics the behaviour of different analytes under elution conditions of practical importance. 相似文献
2.
Teixeira-Neto É Leite CA Cardoso AH Medeiros da Silva MC Braga M Galembeck F 《Journal of colloid and interface science》2000,231(1):182-189
Poly(styrene-co-acrylamide) (PS-AAM) latex was prepared, fractionated by sedimentation under gravity, and characterized by PCS, infrared spectra, secondary and backscattered electron imaging in the scanning electron microscope, and electron spectroscopy imaging in an analytical transmission electron microscope. Three latex fractions were obtained. The lower fraction was opalescent and its particles were the more uniform, concerning size, chemical composition, and topochemical features. This lower fraction was still further fractionated by zonal centrifugation in a density gradient, yielding two fractions with similar macrocrystal-forming abilities but different sizes and chemical compositions. These results confirm those previously obtained for the PS-HEMA latex. Copyright 2000 Academic Press. 相似文献
3.
QuEChERS sample preparation for the determination of pesticides and other organic residues in environmental matrices: a critical review 总被引:4,自引:0,他引:4
Maria Concetta Bruzzoniti Leonardo Checchini Rosa Maria De Carlo Serena Orlandini Luca Rivoira Massimo Del Bubba 《Analytical and bioanalytical chemistry》2014,406(17):4089-4116
Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) is an extraction and clean-up technique originally developed for recovering pesticide residues from fruits and vegetables. Since its introduction, and until December 2013, about 700 papers have been published using the QuEChERS technique, according to a literature overview carried out using SciFinder, Elsevier SciVerse, and Google search engines. Most of these papers were dedicated to pesticide multiresidue analysis in food matrices, and this topic has been thoroughly reviewed over recent years. The QuEChERS approach is now rapidly developing beyond its original field of application to analytes other than pesticides, and matrices other than food, such as biological fluids and non-edible plants, including Chinese medicinal plants. Recently, the QuEChERS concept has spread to environmental applications by analyzing not only pesticides but also other compounds of environmental concern in soil, sediments, and water. To the best of our knowledge, QuEChERS environmental applications have not been reviewed so far; therefore, in this contribution, after a general discussion on the evolution and changes of the original QuEChERS method, a critical survey of the literature regarding environmental applications of conventional and modified QuEChERS methodology is provided. The overall recoveries obtained with QuEChERS and other extraction approaches (e.g., accelerated solvent extraction, ultrasonic solvent extraction, liquid/solid extraction, and soxhlet extraction) were compared, providing evidence for QuEChERS higher recoveries for various classes of compounds, such as biopesticides, chloroalkanes, phenols, and perfluoroalkyl substances. The role of physicochemical properties of soil (i.e., clay and organic carbon content, as well as cation exchange capacity) and target analytes (i.e., log KOW, water solubility, and vapor pressure) were also evaluated in order to interpret recovery and matrix effect data. 相似文献
4.
A study of the mechanisms involved in the separation of metal ions with a mixed-bed stationary phase
Summary The optimization of chromatographic methods for the determination of metal species require an understanding of the mechanisms
involved. In this work, the separation of Cd, Co, Cu, Fe(II/III), Mn, Pb and Zn using a mixed bed column (IonPac CS5A) and
a cation-exchange column (IonPac CS2) is studied as a function of mobile phase composition. The type and concentration of
complexing agent and of ionic strength modificators were evaluated. The charge of analytes were calculated using the classical
ion exchange approach to highlight the effect of eluent composition on retention. The comparative study enabled us to identify
an optimal eluent composition for the separation of the nine metal species. 相似文献
5.
KM Varier AM Vinodkumar NVSV Prasad PV Madhusudhana Rao DL Sastry Lagy T Baby MC Radhakrishna NG Puttaswamy JJ Das P Sugathan N Madhavan AK Sinha DO Kataria 《Pramana》1999,53(3):529-533
Large enhancements have been observed in the sub-barrier fusion cross sections for Ti+Ni systems in our previous studies.
Coupled channel calculations incorporating couplings to 2+ and 3− states failed to explain these enhancements completely. A possibilty of transfer channels contributing to the residual enhancements
had been suggested. In order to investigate the role of relevant transfer channels, measurements of one- and two-nucleon transfer
were carried out for 46,48Ti+61Ni systems. The present paper gives the results of these studies. 相似文献
6.
7.
8.
High performance ion chromatography of haloacetic acids on macrocyclic cryptand anion exchanger 总被引:1,自引:0,他引:1
Bruzzoniti MC De Carlo RM Horvath K Perrachon D Prelle A Tófalvi R Sarzanini C Hajós P 《Journal of chromatography. A》2008,1187(1-2):188-196
A new high performance ion chromatographic method has been developed for the separation of the nine chlorinated-brominated haloacetic acids (HAAs) that are the disinfection by-products of chlorination of drinking water, using a macrocycle-based adjustable-capacity anion-exchange separator column (IonPac Cryptand A1). A gradient method based on theoretical and experimental considerations has been optimized in which 10 mM NaOH-LiOH step gradient was performed at the third minute of the analysis. The optimized method allowed us to separate the nine HAAs and seven possibly interfering inorganic anions in less than 25 min with acceptable resolution. The minimum concentrations detectable for HAAs were between 8.0 (MBA) and 210 (TBA) microg L(-1), with linearity included between 0.9947 (TBA) and 0.9998 (MBA). To increase sensitivity, a 25-fold preconcentration step on a reversed phase substrate (LiChrolut EN) has been coupled. Application of this method to the analysis of haloacetic acids in real tap water samples is illustrated. 相似文献
9.
Morelos A Albuquerque IF Bondar NF Carrigan RA Chen D Cooper PS Lisheng D Denisov AS Dobrovolsky AV Dubbs T Endler AM Escobar CO Foucher M Golovtsov VL Gottschalk H Gouffon P Grachev VT Khanzadeev AV Kubantsev MA Kuropatkin NP Lach J Lang Pengfei Li Chengze Li Yunshan Luksys M Mahon JR McCliment E Newsom C Pommot Maia MC Samsonov VM Schegelsky VA Shi Huanzhang Smith VJ Tang Fukun Terentyev NK Timm S Tkatch II Uvarov LN Vorobyov AA Yan Jie Zhao Wenheng Shuchen Z Zhong Yuanyuan 《Physical review letters》1993,71(21):3417-3420
10.
B. Bonelli M. C. Bruzzoniti E. Garrone E. Mentasti B. Onida C. Sarzanini V. Serafino E. Tarasco 《Chromatographia》2002,56(1):S189-S191
Summary Mesoporous silica-based materials have been synthesized and studied for applications in the environmental field. Haloacetic
acids have been chosen as test compounds since they are byproducts of disinfection processes of water for human consumption.
For this purpose mesoporous materials have been synthesized in acid, basic or neutral conditions. The effect of composition
and synthesis conditions of mesoporous materials on their retention properties have been studied. The retention mechanism
has also been elucidated in term of electrostatic interactions and as a function of the residual surfactant content in the
materials.
Presented at Balaton Symposium '01 on High-Performance Separation Methods, Siófok, Hungary, September 2–4, 2001 相似文献