首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   39篇
  免费   0篇
化学   29篇
晶体学   1篇
数学   4篇
物理学   5篇
  2017年   3篇
  2015年   2篇
  2013年   2篇
  2009年   2篇
  2006年   1篇
  2004年   1篇
  1997年   1篇
  1996年   2篇
  1995年   2篇
  1994年   1篇
  1993年   1篇
  1992年   10篇
  1991年   4篇
  1990年   3篇
  1987年   1篇
  1985年   2篇
  1981年   1篇
排序方式: 共有39条查询结果,搜索用时 46 毫秒
1.
Background: Although microemulsion-based nanoparticles (MEs) may be useful for drug delivery or scavenging, these benefits must be balanced against potential nanotoxicological effects in biological tissue (bio-nano interface). We investigated the actions of assembled MEs and their individual components at the bio-nano interface of thrombosis and hemolysis in human blood. Methods: Oil-in-water MEs were synthesized using ethylbutyrate, sodium caprylate, and pluronic F-68 (ME4) or F-127 (ME6) in 0.9% NaClw/v. The effects of MEs or components on thrombosis were determined using thrombo-elastography, platelet contractile force, clot elastic modulus, and platelet counting. For hemolysis, ME or components were incubated with erythrocytes, centrifuged, and washed for measurement of free hemoglobin by spectroscopy. Results and conclusions: The mean particle diameters (polydispersity index) for ME6 and ME4 were 23.6 ± 2.5 nm (0.362) and 14.0 ± 1.0 nm (0.008), respectively. MEs (0, 0.03, 0.3, 3 mM) markedly reduced the thromboelastograph maximal amplitude in a concentration-dependent manner (49.0 ± 4.2, 39.0 ± 5.6, 15.0 ± 8.7, 3.8 ± 1.3 mm, respectively), an effect highly correlated (r2 = 0.94) with similar changes caused by pluronic surfactants (48.7 ± 10.9, 30.7 ± 15.8, 20.0 ± 11.3, 2.0 ± 0.5) alone. Neither oil nor sodium caprylate alone affected the thromboelastograph. The clot contractile force was reduced by ME (27.3 ± 11.1–6.7 ± 3.4 kdynes/cm2, P = 0.02, n = 5) whereas the platelet population not affected (175 ± 28–182 ± 23 106/ml, P = 0.12, n = 6). This data suggests that MEs reduced platelet activity due to associated pluronic surfactants, but caused minimal changes in protein function necessary for coagulation. Although pharmacological concentrations of sodium caprylate caused hemolysis (EC50 = 213 mM), MEs and pluronic surfactants did not disrupt erythrocytes. Knowledge of nanoparticle activity and potential associated nanotoxicity at this bio-nano interface enables rational ME design for in vivo applications.  相似文献   
2.
3.
The amounts of 137Cs and 90Sr have been determined in the inflows and outflows of the Norwegian sub-alpine lake, Ovre Heimdalsvatn, in March/April during the period of ice-cover, when discharge is extremely stable. The lake is situated in an area contaminated by Chernobyl fallout. The transported course particulate plant material has been collected in traps; the particles and colloids have been removed from water samples by cross-flow ultrafiltration. On the basis of radionuclide inputs and outputs, lake budget calculations have been made for 137Cs and 90Sr during the period of ice-cover. Daily transport of radionuclides is considerably less than that observed during the spring snowmelt period when discharges are high. Size distribution patterns of Cs and Sr observed during winter are compared with previously published data from the same lake during the spring spate. The retention of 137Cs is similar in winter and spring, but retention of 90Sr is greater in winter.  相似文献   
4.
The molecular-size fractionation of aquatic humic substances (HS) and their metal species by means of a novel sequential-stage ultrafiltration (UF) device equipped with five appropriate ultramembranes (1, 5, 10, 50 and 100 kD) is described. First of all, the concentration dynamics of macromolecules, particulary HS, during five-stage UF and its subsequent washing step has been modelled. Based on these results, the fractionation of aquatic HS (from ground and bog water) by means of multistage UF has been optimized for an analytical scale (10 ml sample, 1 mg/ml HS, 10 ml washing solution, pH 6.0). The molecular size-distribution of selected aquatic HS (BOC 1/2 from the DFG-Versuchsfeld Bocholt, VM 5 from Venner Moor, Germany) studied by five-stage UF exhibited strong systematic influences of the procedure used for their isolation. The molecular-size distribution of HS obtained by on-line UF and gel permeation chromatography (GPC) showed a satisfactory agreement in the range 1–50 kD. Moreover, when interrupting multistage UF for > 48 h a slow transformation in the HS samples has been found as gradually additional HS fractions of < 1 kD have been formed. Besides unloaded HS molecules, the molecular-size distribution of freshly formed metal species of HS (1.0 mg metal/g HS of Al(III), Cd(II), Cu(II), Fe(III), Mn(II), Ni(II), Pb(II), Zn(II), each) has been characterized by multistage UF as a function of pH-value, degree of loading and complexation time. Metal determinations as carried out by flame AAS, showed that considerable metal fractions in HS especially are present in molecules > 50 kD, which seemed to be rather acid-inert. With complexation times of < 2 days a transient shift of the molecular size distribution of both HS and their metal species (e.g., Al(III), Fe(III) to higher values (> 10 kD) has been found.  相似文献   
5.
Brit Salbu 《Mikrochimica acta》1991,104(1-6):29-37
Trace elements in natural waters can be present in different physico-chemical forms, varying in size, charge and density properties. Knowledge of speciation is essential for understanding the transport, distribution, and biological uptake of trace elements in the environment. The development of techniques to provide reliable information on physico-chemical forms has, therefore, become a challenge within Analytical Chemistry.When selecting analytical methods for the determination of total concentrations or fractions of trace elements in natural waters, no exclusion of species should occur, or at least it must be accounted for. Furthermore, the determination limits must be sufficiently low to allow the actual concentrations to be determined with reasonable precision and accuracy. For very low concentrations, preconcentration techniques are applicable, provided the chemical yield of the spike represents that of the original species present. For methods meeting these criteria, the suitability for routine analysis should be considered.When the physico-chemical forms of trace elements are to be determined, the fractionation should take placein situ or shortly after sampling. As the concentrations involved in speciation studies may be extremely low, there is an increasing awareness of potential sources of errors influencing analytical results. Sample collection and separation/fractionation/concentration procedures prior to analysis are, therefore, essential within Analytical Chemistry, and the whole procedure must be taken into account when interpreting the results. There are, however, several requirements which should be met by techniques applicable for speciation purposes. In general, size fractionation techniques (e.g.in situ hollow fibre ultrafiltration) should be applied prior to the addition of any chemical reagents (charge fractionation techniques).  相似文献   
6.
Low level90Sr in environmental and biological samples is determined using a combined HDEHP solvent extraction-liquid scintillation procedure. Yttrium-90 is selectively extracted from nitric acid solution into 5% di(2-ethylhexyl) phosphoric acid (HDEHP) in toluene, and90Y in the organic phase is measured directly using an ultra low level liquid scintillation spectrometer.The working program of the Quantulus counter has been optimized. As the counting efficiency using liquid scintillation counting is high and the stripping and precipitation of Yttrium-90 oxalate is omitted, this procedure is simpler and more timesaving than traditional methods. The chemical recoveries of90Y were 85.1% for soil, 75.7% for milk and 65.3% for bone. The detection limit is 8 mBq.  相似文献   
7.
The lack of a suitable tracer has severely limited the use of radioisotope tracer experiments in environmental and biological studies on aluminium. The only aluminium radioisotope with a half-life greater than 10 min is the long-lived positron emitter 26Al (t1/2 7.2 x 10(5) years). The exposure of this nuclide and the difficulty in attaining sufficiently low determination limits with standard radioanalytical techniques have restricted its application as a radioactive tracer. The development of a simple method for the routine determination of 26Al using Cerenkov counting and a Quantalus 1220 low-level liquid scintillation spectrometer is reported. For a 300 min counting time, determination limits of about 60 mBq in water samples and 120 mBq in biological (fish gill) samples can be attained. With these levels of determination, the use of 26Al as a tracer is a viable technique for the study of aluminium in environmental and biological systems.  相似文献   
8.
9.
The performance of a combined microbeam X-ray fluorescence/X-ray powder diffraction (XRF/XRPD) measurement station at Hamburger Synchrotronstrahlungslabor (HASYLAB) Beamline L is discussed in comparison to that at European Synchrotron Radiation Facility (ESRF) ID18F/ID22. The angular resolution in the X-ray diffractograms is documented when different combinations of X-ray source, optics and X-ray diffraction detectors are employed. Typical angular resolution values in the range 0.3–0.5° are obtained at the bending magnet source when a ‘pink’ beam form of excitation is employed. A similar setup at European Synchrotron Radiation Facility beamlines ID18F and ID22 allows to reach angular resolution values of 0.1–0.15°. In order to document the possibilities and limitations for speciation of metals in environmental materials by means of Hamburger Synchrotronstrahlungslabor Beamline L X-ray fluorescence/X-ray powder diffraction setup, two case studies are discussed, one involved in the identification of the crystal phases in which heavy metals such as chromium, iron, barium and lead are present in polluted soils of an industrial site (Val Basento, Italy) and another involved in the speciation of uranium in depleted uranium particles (Ceja Mountains, Kosovo). In the former case, the angular resolution is sufficient to allow identification of most crystalline phases present while in the latter case, it is necessary to dispose of an angular resolution of ca. 0.2° to distinguish between different forms of oxidized uranium.  相似文献   
10.
B Salbu  G Ostby  T H Garmo  K Hove 《The Analyst》1992,117(3):487-491
A rapid and inexpensive incubation and extraction technique for estimating the available low molecular weight and potentially bioavailable fraction of Cs isotopes in vegetation has been developed. Samples of contaminated vegetation (grass, herbage and fungi) and litter were exposed to rumen liquid from sheep, by in vitro incubation or by placing nylon bags in the rumen of sheep (in sacco). The results were compared with laboratory extractions using rumen buffer, NH4OAc, CsCl and de-ionized water. The release of low molecular weight 137Cs species after in vitro incubation with rumen liquid for 4-8 h was 75-85% for grass, herbage and fungi, 30% for lichen and 10% for litter. The reproducibility of the method was 5% for digestible matrices and 10-20% for litter where the fraction of Cs isotopes released was small. Extractions with NH4OAc and CsCl released 75 and 80% of the Cs isotopes in grass, respectively. Significantly lower extraction yields were obtained with de-ionized water and buffer. During in sacco incubation, 90-100% of the Cs isotopes in vegetation was released within 1 h; however, potentially available low molecular weight forms and Cs-bearing colloidal material could not be differentiated. The results obtained by incubation with rumen liquid and by extraction with NH4OAc or CsCl were in good agreement with published data from a 3 week feeding trial. For practical reasons extraction with NH4OAc or CsCl rather than incubation with rumen liquid is recommended for estimating the fraction of available low molecular weight Cs species.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号