首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
化学   11篇
物理学   2篇
  2018年   1篇
  2015年   1篇
  2010年   1篇
  2008年   3篇
  2007年   1篇
  2006年   2篇
  2005年   2篇
  1994年   1篇
  1992年   1篇
排序方式: 共有13条查询结果,搜索用时 15 毫秒
1.
The feasibility of comprehensive two-dimensional gas chromatography with electron-capture detection (GC x GC-ECD) for the enantioseparation of chiral PCBs from other possible interfering compounds has been evaluated. Three commercially available enantioselective beta-cyclodextrin-based capillary columns (Chirasil-Dex, BGB-172 and BGB-176SE) have been tested as first-dimension columns. Three non-enantioselective stationary phases (HT-8, BPX-50 and Supelcowax-10) were combined with the enantioselective columns to allow the unambiguous determination of the enantiomers of the target chiral PCBs. Each enantioselective first-dimension column tested was able to separate into enantiomers different PCB congeners, but in all cases, the use of Supelcowax-10 as second-dimension column provided the most satisfactory results. The Chirasil-Dex x Supelcowax-10 column combination allowed the determination of the enantiomeric fraction (EF) of PCBs 84, 91, 95, 132, 136, 149, 174 and 176 in the working standard solution, while that of congener 135 was hindered. The BGB-172 x Supelcowax-10 column set allowed a proper EF determination of congeners 45, 84, 131, 132, 135, 171, 174 and 183, while that of PCB 91 was interfered with co-elutants. The column combination BGB-176SE x Supelcowax-10 allowed the determination of all congeners that this enantioselective stationary phase was able to separate into enantiomers, i.e. PCBs 45, 91, 95, 136, 149 and 176. These column combinations have also been evaluated for the simultaneous determination of the 12 congeners with a toxic equivalency factor assigned by the WHO (PCBs 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, 189) and the seven indicator congeners (PCBs 28, 52, 101, 118, 138, 153 and 180), and evaluated for the analysis of food samples.  相似文献   
2.
3.
This is a correction to the following paper: Hague T, Petroczi A, Andrews PR, Barker J, Naughton DP: Determination of metal ion content of beverages and estimation of target hazard quotients: a comparative study. Chem Central J 2008, 2:13.  相似文献   
4.
A method based on gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITD-MS/MS), using isotope dilution, was developed for the determination of ten native polybrominated diphenyl ethers (PBDEs) and four (13)C(12)-labeled congeners in biological (fat tissue and human serum) and food samples. The highest-mass fragment ions were used as precursor ions for those congeners with molecular ions with m/z values higher than the maximum of the instrument. In these cases (hepta-BDEs and (13)C(12)-hexa-BDEs) no fragmentation was achieved under the experimental conditions employed. Repeatability (lower than 9%) and reproducibility (lower than 13%), expressed as relative standard deviation (RSD, n = 3 and 4, respectively), were satisfactory. Similarly, the coefficient of variation (n = 4) of the isotopic ratio between the two most abundant product ions was lower than 10 and 6% for native and labeled congeners, respectively. To evaluate the feasibility of the method, the optimized isotope dilution GC/ITD-MS/MS method was used for the quantitation of selected PBDE congeners in different samples including adipose tissue, human serum and foodstuff samples, from three inter-laboratory comparative exercises, covering a wide range of concentrations. A solid-phase extraction procedure, previously developed for PCB determination in small-size bird serum samples, was successfully applied to quantification of PBDEs in 1 mL samples of human serum.  相似文献   
5.
6.

Background  

Considerable research has been directed towards the roles of metal ions in nutrition with metal ion toxicity attracting particular attention. The aim of this study is to measure the levels of metal ions found in selected beverages (red wine, stout and apple juice) and to determine their potential detrimental effects via calculation of the Target Hazard Quotients (THQ) for 250 mL daily consumption.  相似文献   
7.
8.
European legislation has recently established a list of 15 priority polycyclic aromatic hydrocarbons (PAHs) to be monitored in foodstuff. Thus, the accurate determination of these compounds has become a highly relevant issue. The fact that some of these European Union (EU) PAHs differ from those typically analysed, requires the re-evaluation of the instrumental conditions for the proper determination of the new target compounds. In this study, the influence of the stationary phase and dimensions of the GC capillary column on the chromatographic resolution of the 15 EU PAHs has been investigated. Apolar (DB-5 type) and medium polar (DB-17 type) stationary phases with different lengths and film thickness have been evaluated for the separation of the target compounds, with special emphasis on those coelutions involving isomers such as the three benzofluoranthenes included in the EU PAHs. In addition, the influence of the injection technique and the column dimensions on the recovery of the high molecular mass PAHs has been studied. A programmable temperature vaporising (PTV) injector has been used in three different operational modes and the results were compared to those obtained using on-column injection. The experimental parameters involved in the injection step were optimised by using experimental design.  相似文献   
9.
Separations of eight persistent organohalogenated classes of pollutants, organochlorinated pesticides (OCPs), polychlorinated biphenyls (PCBs), polychlorinated diphenyl ethers (PBDEs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated naphthalenes (PCNs), polychlorinated terphenyls (PCTs) and toxaphene (CTT) by comprehensive two-dimensional gas chromatography (GC x GC) were evaluated. Columns with different polarity and selectivity, including ZB-5, HT-8, DB-17 and BP-10, were selected as first dimension and combined with columns of increasing polarity in the second dimension, i.e. HT-8, BPX-50 and Carbowax (or Supelcowax-10). In total nine column combinations were tested. Because the main interest of the study was fast screening of the test xenobiotic families in complex matrices, in all cases, attention was primarily focussed on group-type separation. Nevertheless, within-group separation was also considered, especially for those classes containing particularly toxic congeners, such as PCBs and PCDD/Fs. Although none of the assayed column sets allowed the simultaneous and complete separation of all pollutants classes, some column combinations provided satisfactory separations among selected families and the rest of pollutants investigated. That was, for instance, the case of HT-8 x BPX-50 for PBDEs and PCDD/Fs, DB-17 x HT-8 for PCNs and OCPs and BP-10 x BPX-50 for CTT, PCDD/Fs and PBDEs. The feasibility of the proposed approach for the fast screening of the target classes of pollutants in complex samples was illustrated by the analysis of food and marine fat samples prepared using simplified miniaturised sample treatment methods.  相似文献   
10.
Comprehensive two-dimensional gas chromatography with micro electron-capture detection (GC x GC-microECD) has been evaluated for the enantioseparation of five chiral toxaphenes typically found in real-life samples (Parlar 26, 32, 40, 44 and 50). From the two enantioselective beta-cyclodextrin-based columns evaluated as first dimension column, BGB-176SE and BGB-172, the latter provided the best results and was further combined with three non-enantioselective columns in the second dimension: HT-8, BPX-50 and Supelcowax-10. The combination BGB-172 x BPX-50 was finally selected because it provided a complete separation among all enantiomers. A satisfactory repeatability and reproducibility of the retention times in both the first and the second dimension were observed for all target compounds (RSDs below 0.8%, n = 4). Linear responses in the tested range of 10-200 pg/microl and limits of detection in the range of 2-6 pg/microl were obtained. The repeatability and reproducibility at a concentration of 100 pg/microl, evaluated as the RSDs calculated for the enantiomeric fraction (EF), was better than 11% (n = 4) in all instances. The feasibility of the method developed for real-life analyses was illustrated by the determination of the enantiomeric ratios and concentration levels of the test compounds in four commercial fish oil samples. These results were compared to those obtained by heart-cut multidimensional gas chromatography using the same enantioselective column.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号