首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
化学   13篇
力学   1篇
数学   1篇
物理学   5篇
  2016年   1篇
  2013年   1篇
  2011年   2篇
  2009年   1篇
  2008年   3篇
  2007年   1篇
  2006年   4篇
  2003年   1篇
  2002年   1篇
  2001年   2篇
  1999年   2篇
  1910年   1篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
The kinetics of oxidation of amino acids (Arg, His, Lys, Phe, Thr and Tyr), a dipeptide (Gly-His), and BSA (bovine serum albumin) by two persistent water soluble free radicals of the hydrazyl type has been studied.The rate decreases in the order Arg>Lys>Tyr>Thr>HisBSAPheGly-His with bothfree radicals. Addition to the reaction mixture of - and -cyclodextrin decreases the oxidation rate, probably due to amino acidencapsulation in the cyclodextrin cavity. -Cyclodextrin protects more efficiently against oxidation than -cyclodextrin.  相似文献   
2.
3.
4.
EM Forgan  D Charalambous  PG Kealey 《Pramana》2002,58(5-6):899-901
We have used a variety of microscopic techniques to reveal the structure and motion of flux line arrangements, when the flux lines in low T c type II superconductors are caused to move by a transport current. Using small-angle neutron scattering by the flux line lattice (FLL), we are able to demonstrate directly the alignment by motion of the nearest-neighbor FLL direction. This tends to be parallel to the direction of flux line motion, as had been suspected from two-dimensional simulations. We also see the destruction of the ordered FLL by plastic flow and the bending of flux lines. Another technique that our collaboration has employed is the direct measurement of flux line motion, using the ultra-high-resolution spectroscopy of the neutron spin-echo technique to observe the energy change of neutrons diffracted by moving flux lines. The muon spin rotation (μSR) technique gives the distribution of values of magnetic field within the FLL. We have recently succeeded in performing μSR measurements while the FLL is moving. Such measurements give complementary information about the local speed and orientation of the FLL motion. We conclude by discussing the possible application of this technique to thin film superconductors.  相似文献   
5.
Precise proteomic profiling of limited levels of disease tissue represents an extremely challenging task. Here, we present an effective and reproducible microproteomic workflow for sample sizes of only 10,000 cells that integrates selective sample procurement via laser capture microdissection (LCM), sample clean-up and protein level fractionation using short-range SDS-PAGE, followed by ultrasensitive LC-MS/MS analysis using a 10 μm i.d. porous layer open tubular (PLOT) column. With 10,000 LCM captured mouse hepatocytes for method development and performance assessment, only 10% of the in-gel digest, equivalent to ~1000 cells, was needed per LC-MS/MS analysis. The optimized workflow was applied to the differential proteomic analysis of 10,000 LCM collected primary and metastatic breast cancer cells from the same patient. More than 1100 proteins were identified from each injection with >1700 proteins identified from three LCM samples of 10,000 cells from the same patient (1123 with at least two unique peptides). Label free quantitation (spectral counting) was performed to identify differential protein expression between the primary and metastatic cell populations. Informatics analysis of the resulting data indicated that vesicular transport and extracellular remodeling processes were significantly altered between the two cell types. The ability to extract meaningful biological information from limited, but highly informative cell populations demonstrates the significant benefits of the described microproteomic workflow.  相似文献   
6.
Bones J  Macka M  Paull B 《The Analyst》2007,132(3):208-217
A study comparing recently available 100 x 3 mm id, 200 x 3 mm id monolithic reversed-phase columns with a 50 x 2.1 mm id, 1.8 microm particle packed reversed-phase columns was carried out to determine the most efficient approach (using traditional van Deemter analysis and a modern kinetic plot approach) for the rapid screening of samples for 16 illicit drugs and associated metabolites. A plot of column backpressure versus plate number (N) showed a significant advantage of using the monolithic phases, with the 20 cm monolithic column exhibiting a maximum 15,000 plates at a column backpressure of approximately 70 bar, compared to approximately 7000 plates at 150 bar for the 5 cm 1.8 microm particle packed column. Optimum linear velocities were found to be 0.40 mm s(-1), 0.52 mm s(-1) and 0.98 mm s(-1) for the three above columns, respectively. The 20 cm monolithic column was subsequently applied to the separation and determination of illicit drug contamination on Irish euro banknotes, using methanol extraction followed by LC-MS/MS. Method performance data showed that the new LC-MS/MS method was significantly more sensitive than previous GC-MS/MS based methods for this application, with detection limits in the pg note(-1) region, based upon a 20 microL standard injection. All of the notes examined tested positive for trace quantities of cocaine, with benzoylecgonine detected on 12 of the 45 notes sampled. Traces of heroin were also detected on three of the 45 notes.  相似文献   
7.
A method has been developed for the determination of zinc pyrithione (ZnPT) in environmental water samples using monolithic reversed-phase silica columns for rapid on-line large volume solid phase extraction in tandem with on-line matrix removal using sacrificial strong anion exchange (SAX) columns. This is coupled with reversed-phase liquid chromatography with atmospheric pressure chemical ionisation mass spectrometric detection. Limits of detection in spiked river water samples, using a 200 mL preconcentration volume, were determined as 18 ng L(-1), with a limit of quantitation of 62 ng L(-1). The percentage recovery from spiked river water was found to be 72+/-9 (n=3 extractions), whilst overall method precision, following 10 repeat complete analyses was found to be 27% RSD at 1 microg L(-1). Linearity was determined over the concentration range of 0.25-10 microg L(-1) and the calculated regression coefficient was R(2)=0.9802. The method was used to investigate the environmental fate of zinc pyrithione in waters and its partition coefficient between sediment and water phases.  相似文献   
8.
This paper describes the investigation of the potential of a quadrupole orthogonal acceleration time-of-flight mass spectrometer (Q-TOF) equipped with an atmospheric pressure ionisation interface for quantitative measurements of small molecules separated by reversed phase liquid chromatography. To this end, the detection limits and linear dynamic range in particular were studied in an LC/MS/MS experiment using 3,4-methylenedioxymethamphetamine standards and 3,4-methylenedioxyethylamphetamine for internal standardisation. In a second phase, the experiment was repeated with real biological extracts (whole blood, serum, and vitreous humour). A calibration for 3,4-methylenedioxymethamphetamine and its metabolite 3,4-methylenedioxyamphetamine was prepared in each of these matrices again using 3,4-methylenedioxyethylamphetamine as internal standard. The resulting quantitative data were compared with those obtained by liquid chromatography with fluorescence detection for the same extracts. The Q-TOF results revealed excellent sensitivity and a linear dynamic range of nearly four decades (2-10 000 pg on-column, r(2) = 0.9998, 1/x weighting). Furthermore, all the calibration curves prepared in biological material were superimposable, LC/MS/MS and LC-fluorescence, and the quantitative results for actual samples compared very favourably. It was concluded that the Q-TOF achieves a linear dynamic range for quantitative LC/MS/MS work exceeding that of fluorescence detection and at much better absolute sensitivity. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
9.
Knežević A  Bones J  Kračun SK  Gornik O  Rudd PM  Lauc G 《The Analyst》2011,136(22):4670-4673
A rapid glycomic profiling method is described wherein N-glycans from plasma samples individually labelled with aniline, 2-aminobenzamide and 2-aminoacridone are mixed, co-injected and separated in the same HILIC-fluorescence run. Transfer of the multiplexed method to UPLC-fluorescence permits an increase in sample throughput from 24 to 864 plasma samples per day.  相似文献   
10.
A motion-correcting pulse sequence and reconstruction algorithm, termed TRELLIS, is presented. k-Space is filled using orthogonal overlapping strips and the directions for phase- and frequency-encoding are alternated such that the frequency-encode direction always runs lengthwise along each strip. The overlap between strips is used both for signal averaging and to produce a system of equations that, when solved, quantifies the rotational and translational motion of the object. Results obtained from simulations with computer-generated phantoms, a purpose-built moving phantom, and in human subjects show the method is effective. TRELLIS offers some advantages over existing techniques in that k-space is sampled uniformly and all acquired data are used for both motion detection and image reconstruction.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号