首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   80篇
  免费   1篇
  国内免费   1篇
化学   69篇
数学   4篇
物理学   9篇
  2023年   3篇
  2021年   2篇
  2020年   2篇
  2019年   1篇
  2017年   1篇
  2016年   1篇
  2013年   1篇
  2012年   1篇
  2011年   10篇
  2010年   5篇
  2008年   16篇
  2007年   8篇
  2006年   10篇
  2005年   6篇
  2004年   6篇
  2003年   3篇
  2002年   1篇
  2000年   1篇
  1999年   1篇
  1998年   2篇
  1984年   1篇
排序方式: 共有82条查询结果,搜索用时 109 毫秒
1.
Interactive liquid chromatography (iLC) for polymer analysis is usually applied to the characterisation of distributions other than molar mass. In particular, its use for the determination of chemical-composition, functionality-type and tacticity distributions has been demonstrated. The application of iLC for the determination of molar mass distributions (MMDs), however, has not yet been fully explored. An expanded version of the reversed-phase liquid chromatography model has been developed to describe and predict how the retention behaviour of polydisperse polystyrene samples changes with molar mass. The relationship between molar mass and the parameters of the model has been investigated in some detail and non-linear correlations were found. From the model and the relationships between the model parameters and molar mass, calibration curves (retention time versus molar mass) were constructed to predict changes in chromatographic selectivity across a given molar mass range. These calibration curves were compared to experimentally obtained curves and, in most cases, excellent agreement was found. The dramatic enhancement in selectivity that can be obtained with iLC in comparison to size-exclusion chromatography (SEC) was illustrated by measuring matrix-assisted laser desorption ionisation (MALDI) MS spectra of fractions collected during a gradient-LC separation. In the low-molar mass range, essentially monodisperse fractions were obtained. Calibration curves, predicted by the model and validated experimentally using narrow-dispersity standards and MALDI-MS spectra of fractions, were used to determine the molar mass distribution of some narrowly distributed polystyrene samples. Molar mass distributions for such standards were found to be somewhat lower than the values reported by the manufacturers. The results also deviated from those obtained by MALDI-MS.  相似文献   
2.
ES-285 x HCl [(2S,3R)-2-amino-3-octadecanol hydrochloride] is a novel investigational anticancer agent, which has shown in vitro and in vivo cytotoxic activity against various tumor cell lines with selectivity for certain solid tumors. The pharmaceutical development of ES-285 x HCl warranted the availability of an assay for the quantification and purity determination of ES-285 x HCl active pharmaceutical ingredient (API) and its pharmaceutical dosage form. A liquid chromatographic method (LC) comprising of derivatisation of ES-285 x HCl with phenylisothiocyanate and UV-detection was developed. The method was found to be linear, precise and accurate. The assay also proved selectivity as determined by analysing ES-285 x HCl in combination with 15 analogues and in combination with hydroxypropyl-beta-cyclodextrin, the excipient used in the lyophilised pharmaceutical dosage form. Stress testing showed that the degradation products were separated from the parent compound, confirming its stability indicating capacity. The method was found robust as determined with design of experiments (DoE), which made it possible to predict system suitability responses in worst case experimental conditions and to define criteria for system suitability testing.  相似文献   
3.
高岭石吸附乙烯和苯的Delft分子力学研究   总被引:1,自引:0,他引:1  
运用Delft分子力学(DMM)程序及其粘土和共轭烯烃力场,计算研究了高岭石对乙烯和苯的吸附作用,探讨了吸附对粘土晶体和有机分子的结构、电荷分布和能量的影响,求得了高岭石吸附乙烯和苯的吸附热等重要物理量.  相似文献   
4.
An accurate global potential-energy surface (PES) is reported for H5(+) based on more than 100,000 CCSD(T)/aug-cc-pVTZ ab initio energies. This PES has full permutational symmetry with respect to interchange of H atoms and dissociates to H3(+) and H2. Ten known stationary points of H5(+) are characterized and compared to previous ab initio calculations. Quantum diffusion Monte Carlo calculations are performed on the PES to obtain the zero-point energy of H5(+) and the anharmonic dissociation energy (D0) of H5(+) --> H3(+) + H2. The rigorous zero-point state of H4D+ is also calculated and discussed within the context of a strictly classical approach to obtain the branching ratio of the reaction H4D+ --> H3(+) + HD and H2D+ + H2. Such an approach is taken using the PES and critiqued based on the properties of the quantum zero-point state. Finally, a simple procedure for adding the long range-interaction energy is described.  相似文献   
5.
Information     
  相似文献   
6.
In magnetic resonance imaging with hyperpolarized (HP) noble gases, data is often acquired during prolonged gas delivery from a storage reservoir. However, little is known about the extent to which relaxation within the reservoir will limit the useful acquisition time. For quantitative characterization, 129Xe relaxation was studied in a bag made of polyvinyl fluoride (Tedlar). Particular emphasis was on wall relaxation, as this mechanism is expected to dominate. The HP 129Xe magnetization dynamics in the deflating bag were accurately described by a model assuming dissolution of Xe in the polymer matrix and dipolar relaxation with neighboring nuclear spins. In particular, the wall relaxation rate changed linearly with the surface-to-volume ratio and exhibited a relaxivity of κ=0.392±0.008 cm/h, which is in reasonable agreement with κ=0.331±0.051 cm/h measured in a static Tedlar bag. Estimates for the bulk gas-phase 129Xe relaxation yielded T1bulk=2.55±0.22 h, which is dominated by intrinsic Xe-Xe relaxation, with small additional contributions from magnetic field inhomogeneities and oxygen-induced relaxation. Calculations based on these findings indicate that relaxation may limit HP 129Xe experiments when slow gas delivery rates are employed as, for example, in mouse imaging or vascular infusion experiments.  相似文献   
7.
Journal of Thermal Analysis and Calorimetry - The currently marketed formulation of pazopanib hydrochloride has a poor bioavailability and pharmacokinetic profile. An alternative formulation of the...  相似文献   
8.
Chiral separation by enantioselective liquid-liquid extraction   总被引:1,自引:0,他引:1  
The literature on enantioselective liquid-liquid extraction (ELLE) spans more than half a century of research. Nonetheless, a comprehensive overview has not appeared during the past few decades. Enantioselective liquid-liquid extraction is a technology of interest for a wide range of chemists and chemical engineers in the fields of fine chemicals, pharmaceuticals, agrochemicals, fragrances and foods. In this review the principles and advances of resolution through enantioselective liquid-liquid extraction are discussed, starting with an introduction on the principles of enantioselective liquid-liquid extraction including host-guest chemistry, extraction and phase transfer mechanisms, and multistage liquid-liquid extraction processing. Then the literature on enantioselective liquid-liquid extraction systems is reviewed, structured on extractant classes. The following extractant classes are considered: crown ether based extractants, metal complexes and metalloids, extractants based on tartrates, and a final section with all other types of chiral extractants.  相似文献   
9.
10.
The presence of phased protoporphyrin IX (PpIX) bleach kinetics has been shown to correlate with esophageal response to 5-aminolevulinic acid-based photodynamic therapy (ALA-PDT) in animal models. Here we confirm the existence of phased PpIX photobleaching by increasing the temporal resolution of the fluorescence measurements using the therapeutic illumination and long wavelength fluorescence detection. Furthermore fluorescence differential pathlength spectroscopy (FDPS) was incorporated to provide information on the effects of PpIX and tissue oxygenation distribution on the PpIX bleach kinetics during illumination. ALA at a dose of 200 mg kg(-1) was orally administered to 15 rats, five rats served as control animals. PDT was performed at an in situ measured fluence rate of 75 mW cm(-2) using a total fluence of 54 J cm(-2). Forty-eight hours after PDT the esophagus was excised and histologically examined for PDT-induced damage. Fluence rate and PpIX photobleaching at 705 nm were monitored during therapeutic illumination with the same isotropic probe. A new method, FDPS, was used for superficial measurement on saturation, blood volume, scattering characteristics and PpIX fluorescence. Results showed two-phased PpIX photobleaching that was not related to a (systematic) change in esophageal oxygenation but was associated with an increase in average blood volume. PpIX fluorescence photobleaching measured using FDPS, in which fluorescence signals are only acquired from the superficial layers of the esophagus, showed lower rates of photobleaching and no distinct phases. No clear correlation between two-phased photobleaching and histologic tissue response was found. This study demonstrates the feasibility of measuring fluence rate, PpIX fluorescence and FDPS during PDT in the esophagus. We conclude that the spatial distribution of PpIX significantly influences the kinetics of photobleaching and that there is a complex interrelationship between the distribution of PpIX and the supply of oxygen to the illuminated tissue volume.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号