排序方式: 共有64条查询结果,搜索用时 15 毫秒
1.
B. MacMillan M. Halse M. Schneider L. Fardy Y. H. Chui B. J. Balcom 《Applied magnetic resonance》2002,22(2):247-256
Magnetic resonance imaging has rarely been applied to rigid polymeric materials, due primarily to the strong dipolar coupling and short signal lifetimes inherent in these materials. SPRITE (single point ramped imaging withT 1 enhancement) (B. J. Balcom, R. P. MacGregor, S. D. Beyea, D. P. Green, R. L. Armstrong, T. W. Bremner: J. Magn. Reson. A123, 131–134, 1996) is particularly well suited to imaging solid materials. With SPRITE, the only requirement is thatT 2* be long enough so that the signal can be phase-encoded. The minimum phase encoding time is limited by the maximum gradient strength available and by the instrument deadtime. At present this is usually tens of microseconds and will only improve with refinements in technology. We have used the SPRITE sequence in conjunction with raising the sample temperature to obtain images of rigid polymers that have largely frustrated conventional imaging methods. This approach provides a straightforward and reliable method for imaging a class of samples that, up until now, have been very difficult to image. 相似文献
2.
3.
4.
5.
6.
Cheng Y Huang Q Eić M Balcom BJ 《Langmuir : the ACS journal of surfaces and colloids》2005,21(10):4376-4381
We present the first 13C magnetic resonance imaging study of CO2 transient adsorption/desorption processes in a zeolite 5A column. CO2 transient concentration profiles were measured with a centric scan spin-echo single point imaging technique. The adsorption wave profiles were determined under flow conditions, with the results analyzed by the Bohart-Adams model. The model adequately accounts for the spatial and the temporal behavior of CO2 in the column. CO2 adsorption rate constants were calculated from the fit. Desorption profiles were acquired by blowing a helium stream through a zeolite 5A column saturated with CO2. An asymmetry between the adsorption and desorption profiles is readily apparent. A linear relationship between the CO2 condensed phase concentration and square root of time was observed. 相似文献
7.
8.
A compact permanent magnet array with a remote homogeneous field 总被引:1,自引:0,他引:1
Marble AE Mastikhin IV Colpitts BG Balcom BJ 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2007,186(1):100-104
We present the design and construction of a single sided magnet array generating a homogeneous field in a remote volume. The compact array measures 11.5 cm by 10 cm by 6 cm and weights approximately 5 kg. It produces a B(0) field with a 'sweet spot' at a point 1cm above its surface, where its first and second spatial derivatives are approximately zero. Unlike other sweet spot magnets of this general type, our array has B(0) oriented parallel to its surface. This allows an ordinary surface coil to be used for unilateral measurements, giving the potential for dramatic SNR improvement. 相似文献
9.
Marble AE Mastikhin IV MacGregor RP Akl M LaPlante G Colpitts BG Lee-Sullivan P Balcom BJ 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2004,168(1):164-174
The results of a magnetic resonance imaging (MRI) investigation concerning the effects of an aluminum honeycomb sandwich panel on the B1 and B0 fields and on subsequent image quality are presented. Although the sandwich panel structure, representative of an aircraft composite material, distorts B0 and attenuates B1, distortion-free imaging is possible using single point (constant time) imaging techniques. A new expression is derived for the error caused by gradient field distortion due to the heterogeneous magnetic susceptibility within a sample and this error is shown not to cause geometric distortion in the image. The origin of the B0 distortion in the sample under investigation was also examined. The graphite-epoxy 'skin' of the panel is the principal source of the B0 distortion. Successful imaging of these structures sets the stage for the development of methods for detecting moisture ingress and degradation within composite sandwich structures. 相似文献
10.
Halse M Rioux J Romanzetti S Kaffanke J MacMillan B Mastikhin I Shah NJ Aubanel E Balcom BJ 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2004,169(1):102-117
Two strategies for the optimization of centric scan SPRITE (single point ramped imaging with T1 enhancement) magnetic resonance imaging techniques are presented. Point spread functions (PSF) for the centric scan SPRITE methodologies are numerically simulated, and the blurring manifested in a centric scan SPRITE image through PSF convolution is characterized. Optimal choices of imaging parameters and k-space sampling scheme are predicted to obtain maximum signal-to-noise ratio (SNR) while maintaining acceptable image resolution. The point spread function simulation predictions are verified experimentally. The acquisition of multiple FID points following each RF excitation is described and the use of the Chirp z-Transform algorithm for the scaling of field of view (FOV) of the reconstructed images is illustrated. Effective recombination of the rescaled images for SNR improvement and T*2 mapping is demonstrated. 相似文献