首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   48篇
  免费   1篇
化学   37篇
力学   2篇
数学   8篇
物理学   2篇
  2023年   1篇
  2022年   1篇
  2020年   2篇
  2019年   4篇
  2017年   3篇
  2016年   3篇
  2015年   1篇
  2014年   2篇
  2013年   8篇
  2012年   3篇
  2011年   2篇
  2010年   1篇
  2009年   3篇
  2008年   4篇
  2006年   4篇
  2005年   4篇
  2004年   1篇
  2002年   1篇
  1995年   1篇
排序方式: 共有49条查询结果,搜索用时 15 毫秒
1.
Baytak S  Türker AR 《Talanta》2005,65(4):938-945
A microorganism Agrobacterium tumefacients as an immobilized cell on a solid support was presented as a new biosorbent for the enrichment of Fe(III), Co(II), Mn(II) and Cr(III) prior to flame atomic absorption spectrometric analysis. Amberlite XAD-4 was used as a support material for column preconcentration. Various parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of sample solution, volume of sample solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH for the sorption of above mentioned metal ions were about 6, 8, 8 and 6, respectively. The loading capacity of adsorbent for Co(II) and Mn(II) were found to be 29 and 22 μmol g−1, respectively. The recoveries of Fe(III), Co(II), Mn(II) and Cr(III), under the optimum conditions were found to be 99 ± 3, 99 ± 2, 98 ± 3 and 98 ± 3%, respectively, at the 95% confidence level. The limit of detection was 3.6, 3.0, 2.8 and 3.6 ng ml−1 for Fe(III), Co(II), Mn(II) and Cr (III), respectively, by applying a preconcentration factor of 25. The proposed enrichment method was applied for metal ion determination from water samples, alloy samples, infant foods and certified samples such as whey powder (IAEA-155) and aluminum alloy (NBS SRM 85b). The analytes were determined with a relative error lower than 10% in all samples.  相似文献   
2.
Investigation of the constituents of the fruits of Morus alba LINNE (Moraceae) afforded five new nortropane alkaloids (1-5) along with nor-psi-tropine (6) and six new amino acids, morusimic acids A-F (7-12). The structures of the new compounds were determined to be 2alpha,3beta-dihydroxynortropane (1), 2beta,3beta-dihydroxynortropane (2), 2alpha,3beta,6exo-trihydroxynortropane (3), 2alpha,3beta,4alpha-rihydroxynortropane (4), 3beta,6exo-dihydroxynortropane (5), (3R)-3-hydroxy-12-[(1S,4S)-4-[(1S)-1-hydroxyethyl]-pyrrolidin-1-yll-dodecanoic acid-3-O-beta-D-glucopyranoside (7), (3R)-3-hydroxy-12-[(1S,4S)-4-[(1S)-1-hydroxyethyl]-pyrrolidin-1-yll-dodecanoic acid (8), (3R)-3-hydroxy-12-1(1R,4R,5S)-4-hydroxy-5-methyl-piperidin-1-yll-dodecanoic acid-3-O-beta-D-glucopyranoside (9), (3R)-3-hydroxy-12-[(1R,4R,5S)-4-hydroxy-5-methyl-piperidin-1-yll-dodecanoic acid (10), (3R)-3-hydroxy-12-[(1R,4R,5S)-4-hydroxy-5-hydroxymethyl-piperidin-1-yl]-dodecanoic acid-3-O-beta-D-glucopyranoside (11), and (3R)-3-hydroxy-12-[(1R,4S,5S)-4-hydroxy-5-methyl-piperidin-1-yl]-dodecanoic acid (12) on the basis of spectral and chemical data.  相似文献   
3.
Journal of Sol-Gel Science and Technology - New silicon boron oxycarbide (SiBOC) preceramic polymers were synthesized via sol–gel method by using n-butyltrimethoxysilane and...  相似文献   
4.
Russian Journal of Electrochemistry - In this study, a new biosensor for amisulpride (ASP) determination is defined. The interaction between ASP and fish sperm double-stranded DNA (FSdsDNA) was...  相似文献   
5.
A novel chiral calix[4](azoxa)crown-7 (9) has been synthesized and its metal ion recognition properties investigated. The starting reagents, chiral diamine 5 and calix[4]arene diacid chloride derivative 8, were prepared according to literature methods. 1H and 13C NMR data show that 9 exists in a cone conformation. In liquid–liquid extraction experiments, 9 exhibits selectivity for Li+ among the other alkali metals and a good extraction ability for transition metal cations, suggesting its potential use in different fields, such as a sensor for ions as well as for chiral molecules.  相似文献   
6.
A voltammetric study of the oxidation of Ceftazidime (CEFT) has been carried out at the glassy carbon electrode by cyclic, differential pulse (DPV) and square wave (SWV) voltammetry. The oxidation of CEFT was irreversible and exhibited diffusion controlled process depending on pH. The oxidation mechanism was proposed and discussed. According to the linear relationship between the peak current and concentration, DPV and SWV voltammetric methods for CEFT assay in pharmaceutical dosage forms and human urine were developed. For analytical purposes, a well resolved diffusion controlled voltammetric peak was obtained in 0.1 M H2SO4 at 1.00 and 1.02 V for differential pulse and square wave voltammetric techniques, respectively. The linear response was obtained within the range of 4 × 10?6?8 × 10?5 M with a detection limit of 6 × 10?7 M for differential pulse and 4 × 10?6–2 × 10?4 M with a detection limit of 1 × 10?6 M for square wave voltammetric technique. The determination of CEFT in 0.1 M H2SO4 was possible over the 2 × 10?6–1 × 10?4 M range in urine sample for both techniques. The standard addition method was used for the recovery studies.  相似文献   
7.
The polymerization of tetrahydrofuran was initiated with 4,4′-azobis(4-cyanovaleryl chloride) in conjunction with silver hexafluoroantimonate and the living polytetrahydrofuran (PTHF) was terminated with pyridinium N-oxide derivatives. The resulting PTHF-macroinitiator possesses both a thermally and photochemically labile group.  相似文献   
8.
A platform based on praseodymium doped dysprosium oxide-carbon nanofibers modified electrode was constructed for the simultaneous determination of SY and TAR. SEM, EDX and XRD techniques were utilized for characterizing the proposed material. The voltammetric behaviour and properties of SY and TAR were gradually improved at materials in order from CNFs to Dy2O3−CNFs and Pr6O11@Dy2O3−CNFs. The working range was found to be 1.0×10−9–3.5×10−8 M and 1.5×10−9–4.0×10−8 M for SY and TAR, respectively. The value of LOD was 3.12×10−10 M and 5.35×10−10 M for SY and TAR, respectively. The platform (Pr6O11@Dy2O3−CNFs/GCE) was successfully applied to the electroanalysis of samples.  相似文献   
9.
A reliable and reproducible method for the determination of uric acid in urine samples has been developed. The method is based on the modification of a glassy carbon electrode by 3-acetylthiophene using cyclic voltammetry. The poly(3-acetylthiophene) modified glassy carbon electrode showed an excellent electrocatalytic effect towards the oxidation of uric acid in 0.1 m phosphate buffer solution (PBS) at pH 7.2. Compared with a bare glassy carbon electrode (GCE), an obvious shift of the oxidation peak potential in the cathodic direction and a marked enhancement of the anodic current response for uric acid were observed. The poly(3-acetylthiophene)/GCE was used for the determination of uric acid using square wave voltammetry. The peak current increased linearly with the concentration of uric acid in the range of 1.25 x 10(-5)-1.75 x 10(-4) M. The detection limit was 5.27 x 10(-7) M by square wave voltammetry. The poly(3-acetylthiophene)/GCE was also effective to determine uric acid and ascorbic acid in a mixture and resolved the overlapping anodic peaks of these two species into two well-defined voltammetric peaks in cyclic voltammetry at 0.030 V and 0.320 V (vs. Ag/AgCl) for ascorbic acid and uric acid, respectively. The modified electrode exhibited stable and sensitive current responses toward uric acid and ascorbic acid. The method has successfully been applied for determination of uric acid in urine samples.  相似文献   
10.
The preconcentration of chromium(III) by solid phase extraction and its determination from aqueous solutions by flame atomic absorption spectrometry (FAAS) is investigated by applying an experimental design. The optimization of the preconcentration variables such as pH of the sample solution, flow rate of the sample solution and concentration of elution solution was carried out using 23 full factorial design. The most important parameter affecting the preconcentration of chromium is the concentration of eluent. In the established experimental conditions, chromium can be determined with a relative standard deviation of 2.0% (N = 7) for a chromium concentration of 100 μg L−1. The detection limit for chromium was 1 μg L−1 (N = 20). The adsorption capacity of Amberlyst 36 is found to be 90.9 mg g−1 for chromium. Effect of other ions on the procedure was also evaluated. The method was validated by the analysis of certified reference materials (tea leaves GBW 07605 and fish tissue IAEA-407). The method was applied to the determination of chromium in waste water, dam water, carrot, parsley and lettuce. Correspondence: Ali Rehber Türker, Department of Chemistry, Faculty of Science and Arts, Gazi University, TR-06500 Ankara, Turkey  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号