排序方式: 共有40条查询结果,搜索用时 15 毫秒
1.
A simple and sensitive spectrophotometric determination of bismuth(III) is based on the reaction between bismuth(III) and o-hydroxyhydroquinonephthalein in the presence of Brij 58 in acidic media. The calibration graph is linear over the range 0-3.5 mug/ml bismuth(III) in the final solution, and the apparent molar absorptivity at 520 nm is 9.03 x 10(4) l. mole(-1). cm(-1). The proposed method is 2-10 times more sensitive than other methods, and simpler. It has been applied to the assay of bismuth(III) in pharmaceutical preparations, such as dermatol and bismuth subnitrate, with good results. 相似文献
2.
3.
In this paper, the extension of an upwind least‐square based meshless solver to high Reynolds number flow is explored, and the properties of the meshless solver are analyzed both theoretically and numerically. Existing works have verified the meshless solver mostly with inviscid flows and low Reynolds number flows, and in this work, we are interested in the behavior of the meshless solver for high Reynolds number flow, especially in the near‐wall region. With both theoretical and numerical analysis, the effects of two parameters on the meshless solver are identified. The first one is the misalignment effect caused by the significantly skewed supporting points, and it is found that the meshless solver still yields accurate prediction. It is a very interesting property and is opposite to the median‐dual control volume based vertex‐centered finite volume method, which is known to give degraded result with stretched triangular/tetrahedral cells in the near‐wall region. The second parameter is the curvature, and according to theoretical analysis, it is found in the region with both large aspect ratio and curvature, and the streamwise residual is less affected; however, the wall‐normal counterpart suffers from accuracy degradation. In this paper, an improved method that uses a meshless solver for the streamwise residual and finite difference for wall‐normal residual is developed. This method is proved to be less sensitive to the curvature and provides improved accuracy. This work presents an understanding of the meshless solver for high Reynolds number flow computation, and the analysis in this paper is verified with a series of numerical experiments. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
4.
André G. Pernet Hiromasa Nakamoto Naoyasu Ishizuka Masakazu Aburatani Kazuaki Nakahashi Keiji Sakamoto Tadashi Takeuchi 《Tetrahedron letters》1979,20(41):3933-3936
A simplified methodology for the building of prostaglandins substituted at the 10 and 11 positions is presented. 相似文献
5.
In this paper, the efficient application of high‐order weighted essentially nonoscillatory (WENO) reconstruction to the subsonic and transonic engineering problems is studied. On the basis of the physical considerations, two techniques are proposed to enhance the accuracy and efficiency of the WENO reconstruction. First, it is observed that the WENO scheme using characteristic variable has better accuracy and convergence speed than the scheme using primitive variable. For engineering problems with shock of moderate amplitude, on the basis of the Rankine–Hugoniot conditions, a simplified characteristic‐variable‐based WENO is developed. The simplified version significantly reduces the cost overhead without sacrificing the shock‐capturing capability. Second, in this work, it is found for viscous case that it is better to include the viscous effect. On the basis of a simple analysis, the viscous correction to the parameter ε in the WENO reconstruction is proposed. Numerical results indicate, with the proposed simplified characteristic‐variable‐based reconstruction and the viscous correction, that the nonlinear WENO interpolation is sharply activated in the region of shock jump, whereas in the shockless area, the WENO interpolation weights are tuned towards the designed optimal value for better accuracy. Compared with the original characteristic‐variable‐based WENO, the current implementation has similar accuracy and reduced cost. At the same time, compared with the primitive variable‐based WENO, better accuracy and convergence speed are obtained at marginal cost overhead. Several practical cases are calculated to demonstrate the accuracy and efficiency of the current methodology. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
6.
7.
This paper presents an approach to the generation of unstructured surface meshes for Computer‐Aided Design (CAD) surface models represented as lists of polygons with minimum user interventions. Stereolithography (STL) data are adopted as an interface between a CAD system and the surface grid generator. STL files often include problems such as overlapping surfaces, gaps, and intersections. They have to be revised quickly and automatically before the surface models are used for the background grid of the surface grid generation. In this paper, we describe an automatic revision method for use with STL‐defined surface models. The advancing front method using geometric features is adopted directly on the modified STL surfaces. The capability of the method is demonstrated for several 3D surface models. Copyright © 2002 John Wiley & Sons, Ltd. 相似文献
8.
9.
I. Mori Y. Fujita K. Fujita Y. Nakahashi R. Matsuo K. Kato 《Fresenius' Journal of Analytical Chemistry》1989,333(1):42-45
Summary The formation of complexes amongst vanadium, o-hydroxyhydroquinonephthalein (Qnph), or/and chlorpromazine hydrochloride (CP · HCl), as a phenothiazine drug, in non-ionic surfactant micellar media was fluorometrically investigated in weakly acidic media. Fluorometric methods for the determination of vanadium and CP · HCl were respectively established by measuring the difference of relative fluorescence intensities (F) between Qnph and Qnph-vanadium solutions, andF between Qnph-vanadyl and Qnph-vanadyl-CP · HCl solutions at an emission wavelength of 540 nm with excitation at 400 nm in the presence of polyvinyl alcohol (PVA) micelles. The calibration graphs were linear in the ranges of 0–0.5 vanadium and 0–220 g CP · HCl per 10 ml of aqueous solution. The relative standard deviations (5 replicates) were 2.5% for 0.2 g vanadium and 1.3% for 100 g CP · HCl per 10 ml of aqueous solution, respectively. The applications to assays of vanadium in water and CP · HCl preparations were investigated, and the results were relatively good.
Application of xanthene derivatives in analytical chemistry. Part LXXIII. Part LXXII see ref. [1] 相似文献
Fluorescenzreaktion von o-Hydroxyhydrochinonphthalein und Vanadium in micellaren Medien und deren Anwendung
Application of xanthene derivatives in analytical chemistry. Part LXXIII. Part LXXII see ref. [1] 相似文献
10.